248 research outputs found

    Robotic manipulators for in situ inspections of jet engines

    Get PDF
    Jet engines need to be inspected periodically and, in some instances, repaired. Currently, some of these maintenance operations require the engine to be removed from the wing and dismantled, which has a significant associated cost. The capability of performing some of these inspections and repairs while the engine is on-wing could lead to important cost savings. However, existing technology for on-wing operations is limited, and does not suffice to satisfy some of the needs. In this work, the problem of performing on-wing operations such as inspection and repair is analysed, and after an extensive literature review, a novel robotic system for the on-wing insertion and deployment of probes or other tools is proposed. The system consists of a fine-positioner, which is a miniature and dexterous robotic manipulator; a gross-positioner, which is a device to insert the fine-positioner to the engine region of interest; an end-effector, such as a probe; a deployment mechanism, which is a passive device to ensure correct contact between probe and component; and a feedback system that provides information about the robot state for control. The research and development work conducted to address the main challenges to create this robotic system is presented in this thesis. The work is focussed on the fine-positioner, as it is the most relevant and complex part of the system. After a literature review of relevant work, and as part of the exploration of potential robot concepts for the system, the kinematic capabilities of concentric tube robots (CTRs) are first investigated. The complete set of stable trajectories that can be traced in follow-the-leader motion is discovered. A case study involving simulations and an experiment is then presented to showcase and verify the work. The research findings indicate that CTRs are not suitable for the fine-positioner. However, they show that CTRs with non-annular cross section can be used for the gross-positioner. In addition, the new trajectories discovered show promise in minimally invasive surgery (MIS). Soft robotic manipulators with fluidic actuation are then selected as the most suitable concept for the fine-positioner. The design of soft robotic manipulators with fluidic actuation is investigated from a general perspective. A general framework for the design of these devices is proposed, and a set of design principles are derived. These principles are first applied in a MIS case study to illustrate and verify the work. Finite element (FE) simulations are then reported to perform design optimisation, and thus complete the case study. The design study is then applied to determine the most suitable design for the fine-positioner. An additional analytical derivation is developed, followed by FE simulations, which extend those of the case study. Eventually, this work yields a final design of the fine-positioner. The final design found is different from existing ones, and is shown to provide an important performance improvement with respect to existing soft robots in terms of wrenches it can support. The control of soft and continuum robots relevant to the fine-positioner is also studied. The full kinematics of continuum robots with constant curvature bending and extending capabilities are first investigated, which correspond to a preliminary design concept conceived for the fine-positioner. Closed-form solutions are derived, closing an open problem. These kinematics, however, do not exactly match the final fine-positioner design selected. Thus, an alternative control approach based on closed-loop control laws is then adopted. For this, a mechanical model is first developed. Closed-loop control laws are then derived based on this mechanical model for planar operation of a segment of the fine-positioner. The control laws obtained represent the foundation for the subsequent development of control laws for a full fine-positioner operating in 3D. Furthermore, work on path planning for nonholonomic systems is also reported, and a new algorithm is presented, which can be applied for the insertion of the overall robotic system. Solutions to the other parts of the robotic system for on-wing operations are also reported. A gross-positioner consisting of a non-annular CTR is proposed. Solutions for a deployment mechanism are also presented. Potential feedback systems are outlined. In addition, methods for the fabrication of the systems are reported, and the electronics and systems required for the assembly of the different parts are described. Finally, the use of the robotic system to perform on-wing inspections in a representative case study is studied to determine the viability. Inspection strategies are shortlisted, and simulations and experiments are used to study them. The results, however, indicate that inspection is not viable since the signal to noise ratio is excessively low. Nonetheless, the robotic system proposed, and the research conducted, are still expected to be useful to perform a range of on-wing operations that require the insertion and deployment of a probe or other end-effector. In addition, the trajectories discovered for CTRs, the design found for the fine-positioner, and the advances on control, also have significant potential in MIS, where there is an important need for miniature robotic manipulators and similar devices.Open Acces

    A Continuum Robot and Control Interface for Surgical Assist in Fetoscopic Interventions

    Get PDF
    Twin-twin transfusion syndrome requires interventional treatment using a fetoscopically introduced laser to sever the shared blood supply between the fetuses. This is a delicate procedure relying on small instrumentation with limited articulation to guide the laser tip and a narrow field of view to visualize all relevant vascular connections. In this letter, we report on a mechatronic design for a comanipulated instrument that combines concentric tube actuation to a larger manipulator constrained by a remote centre of motion. A stereoscopic camera is mounted at the distal tip and used for imaging. Our mechanism provides enhanced dexterity and stability of the imaging device. We demonstrate that the imaging system can be used for computing geometry and enhancing the view at the operating site. Results using electromagnetic sensors for verification and comparison to visual odometry from the distal sensor show that our system is promising and can be developed further for multiple clinical needs in fetoscopic procedures

    Design and Modeling of Multi-Arm Continuum Robots

    Get PDF
    Continuum robots are snake-like systems able to deliver optimal therapies to pathologies deep inside the human cavity by following 3D complex paths. They show promise when anatomical pathways need to be traversed thanks to their enhanced flexibility and dexterity and show advantages when deployed in the field of single-port surgery. This PhD thesis concerns the development and modelling of multi-arm and hybrid continuum robots for medical interventions. The flexibility and steerability of the robot’s end-effector are achieved through concentric tube technology and push/pull technology. Medical robotic prototypes have been designed as proof of concepts and testbeds of the proposed theoretical works.System design considers the limitations and constraints that occur in the surgical procedures for which the systems were proposed for. Specifically, two surgical applications are considered. Our first prototype was designed to deliver multiple tools to the eye cavity for deep orbital interventions focusing on a currently invasive intervention named Optic Nerve Sheath Fenestration (ONSF). This thesis presents the end-to-end design, engineering and modelling of the prototype. The developed prototype is the first suggested system to tackle the challenges (limited workspace, need for enhanced flexibility and dexterity, danger for harming tissue with rigid instruments, extensive manipulation of the eye) arising in ONSF. It was designed taking into account the clinical requirements and constraints while theoretical works employing the Cosserat rod theory predict the shape of the continuum end-effector. Experimental runs including ex vivo experimental evaluations, mock-up surgical scenarios and tests with and without loading conditions prove the concept of accessing the eye cavity. Moreover, a continuum robot for thoracic interventions employing push/pull technology was designed and manufactured. The developed system can reach deep seated pathologies in the lungs and access regions in the bronchial tree that are inaccessible with rigid and straight instruments either robotically or manually actuated. A geometrically exact model of the robot that considers both the geometry of the robot and mechanical properties of the backbones is presented. It can predict the shape of the bronchoscope without the constant curvature assumption. The proposed model can also predict the robot shape and micro-scale movements accurately in contrast to the classic geometric model which provides an accurate description of the robot’s differential kinematics for large scale movements

    Concentric Tube Robot Design and Optimization Based on Task and Anatomical Constraints

    Get PDF
    Concentric tube robots are catheter-sized continuum robots that are well suited for minimally invasive surgery inside confined body cavities. These robots are constructed from sets of pre-curved superelastic tubes and are capable of assuming complex 3D curves. The family of 3D curves that the robot can assume depends on the number, curvatures, lengths and stiffnesses of the tubes in its tube set. The robot design problem involves solving for a tube set that will produce the family of curves necessary to perform a surgical procedure. At a minimum, these curves must enable the robot to smoothly extend into the body and to manipulate tools over the desired surgical workspace while respecting anatomical constraints. This paper introduces an optimization framework that utilizes procedureor patient-specific image-based anatomical models along with surgical workspace requirements to generate robot tube set designs. The algorithm searches for designs that minimize robot length and curvature and for which all paths required for the procedure consist of stable robot configurations. Two mechanics-based kinematic models are used. Initial designs are sought using a model assuming torsional rigidity. These designs are then refined using a torsionally-compliant model. The approach is illustrated with clinically relevant examples from neurosurgery and intracardiac surgery

    Modeling, Sensorization and Control of Concentric-Tube Robots

    Get PDF
    Since the concept of the Concentric-Tube Robot (CTR) was proposed in 2006, CTRs have been a popular research topic in the field of surgical robotics. The unique mechanical design of this robot allows it to navigate through narrow channels in the human anatomy and operate in highly constrained environments. It is therefore likely to become the next generation of surgical robots to overcome the challenges that cannot be addressed by current technologies. In CSTAR, we have had ongoing work over the past several years aimed at developing novel techniques and technologies for CTRs. This thesis describes the contributions made in this context, focusing primarily on topics such as modeling, sensorization, and control of CTRs. Prior to this work, one of the main challenges in CTRs was to develop a kinematic model that achieves a balance between the numerical accuracy and computational efficiency for surgical applications. In this thesis, a fast kinematic model of CTRs is proposed, which can be solved at a comparatively fast rate (0.2 ms) with minimal loss of accuracy (0.1 mm) for a 3-tube CTR. A Jacobian matrix is derived based on this model, leading to the development of a real-time trajectory tracking controller for CTRs. For tissue-robot interactions, a force-rejection controller is proposed for position control of CTRs under time-varying force disturbances. In contrast to rigid-link robots, instability of position control could be caused by non-unique solutions to the forward kinematics of CTRs. This phenomenon is modeled and analyzed, resulting in design criteria that can ensure kinematic stability of a CTR in its entire workspace. Force sensing is another major difficulty for CTRs. To address this issue, commercial force/torque sensors (Nano43, ATI Industrial Automation, United States) are integrated into one of our CTR prototypes. These force/torque sensors are replaced by Fiber-Bragg Grating (FBG) sensors that are helically-wrapped and embedded in CTRs. A strain-force calculation algorithm is proposed, to convert the reflected wavelength of FBGs into force measurements with 0.1 N force resolution at 100 Hz sampling rate. In addition, this thesis reports on our innovations in prototyping drive units for CTRs. Three designs of CTR prototypes are proposed, the latest one being significantly more compact and cost efficient in comparison with most designs in the literature. All of these contributions have brought this technology a few steps closer to being used in operating rooms. Some of the techniques and technologies mentioned above are not merely limited to CTRs, but are also suitable for problems arising in other types of surgical robots, for example, for sensorizing da Vinci surgical instruments for force sensing (see Appendix A)

    Space-Capable Long and Thin Continuum Robotic Cable

    Get PDF
    Design of continuum robots, i.e. robots with continuous backbones, has been an active area of research in robotics for minimally invasive surgery, search and rescue, object manipulation, etc. Along the same lines, NASA developed Tendril , the first long and thin continuum robot of its kind, intended for in-space inspection applications. The thesis starts with describing and discussing the key disadvantages of the current state of the art mechanical design of Tendril\u27\u27 producing undesirable effects during operation. It then includes the design specifics of a novel concept for construction of a next generation long and thin, space-cable, multi-section, continuum cable-like robot, with a modified mechanical design for better performance. The new design possesses key features including controllable bending along its entire length, local compression and a compact actuation package. This new design is detailed in two versions. The first is a planar variant (suited for a 2D workspace), explaining the principle which allows the cable robot to achieve the above mentioned features. It is followed by a refined spatial version (suited for 3D workspace), where the functional characteristics are achieved within the desired aspect ratio of thin (less than 1 cm diameter) and relatively longer length (more than 100 cm) of the robotic cable. A new forward kinematic model is then developed extending the established models for constant-curvature continuum robots, to account for the new design feature of controllable compression (in the hardware) and is validated by performing experiments with the robot in (2D) planar and (3D) spatial scenarios. This new model is found to be effective as a baseline to predict the performance of such a long and thin continuum cable\u27\u27 robot

    Novel Vine-like Continuum Robot for Environmental Exploration Applications

    Get PDF
    This thesis details a new design and novel operational strategies for nature inspired, thin tendril continuum robots. Instead of taking inspiration for robot design from insects or animals, the novel approach to continuum robotics herein takes inspiration and adapts operational concepts from plant life. In particular, an innovative strategy is developed which mimics behaviors observed in vines and other climbing plants. Specifically, a tendril robot with prickles was developed and deployed to actively seek environmental contact, exploiting the mechanical advantage gained by bracing against the environment using the prickles. The resulting performance enhancements over previously developed smooth backbone tendril robot designs, and use of strategies that do not attempt to interact with the environment are empirically demonstrated with the new robot prototype. Results of further experiments suggest applications in which the new design and approach could prove useful to the scientific and wider communities

    An efficient follow-the-leader strategy for continuum robot navigation and coiling

    Get PDF
    Efficient path planning for hyper-redundant continuum and snake-like robots is a challenging task due to limited sensing capabilities, high computational loads, multiple possible solutions, and non-linear models. This paper presents a new approach to snake robot navigation and coiling, with an algorithm that enables online step-by-step position adjustment with a follow-the-leader strategy, significantly improving the performance of the robot when compared to previous methods. The proposed algorithm is demonstrated on a 16-degree-of-freedom snake-like robot for inspection and maintenance tasks in nuclear facilities

    Snake Robots for Surgical Applications: A Review

    Get PDF
    Although substantial advancements have been achieved in robot-assisted surgery, the blueprint to existing snake robotics predominantly focuses on the preliminary structural design, control, and human–robot interfaces, with features which have not been particularly explored in the literature. This paper aims to conduct a review of planning and operation concepts of hyper-redundant serpentine robots for surgical use, as well as any future challenges and solutions for better manipulation. Current researchers in the field of the manufacture and navigation of snake robots have faced issues, such as a low dexterity of the end-effectors around delicate organs, state estimation and the lack of depth perception on two-dimensional screens. A wide range of robots have been analysed, such as the i2Snake robot, inspiring the use of force and position feedback, visual servoing and augmented reality (AR). We present the types of actuation methods, robot kinematics, dynamics, sensing, and prospects of AR integration in snake robots, whilst addressing their shortcomings to facilitate the surgeon’s task. For a smoother gait control, validation and optimization algorithms such as deep learning databases are examined to mitigate redundancy in module linkage backlash and accidental self-collision. In essence, we aim to provide an outlook on robot configurations during motion by enhancing their material compositions within anatomical biocompatibility standards

    A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation

    Get PDF
    The application of laser technologies in surgical interventions has been accepted in the clinical domain due to their atraumatic properties. In addition to manual application of fibre-guided lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours has been prevailed in ENT surgery. However, TLM requires many years of surgical training for tumour resection in order to preserve the function of adjacent organs and thus preserve the patient’s quality of life. The positioning of the microscopic laser applicator outside the patient can also impede a direct line-of-sight to the target area due to anatomical variability and limit the working space. Further clinical challenges include positioning the laser focus on the tissue surface, imaging, planning and performing laser ablation, and motion of the target area during surgery. This dissertation aims to address the limitations of TLM through robotic approaches and intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no highly integrated platform for endoscopic delivery of focused laser radiation is available to date. Likewise, there are no known devices that incorporate scene information from endoscopic imaging into ablation planning and execution. For focusing of the laser beam close to the target tissue, this work first presents miniaturised focusing optics that can be integrated into endoscopic systems. Experimental trials characterise the optical properties and the ablation performance. A robotic platform is realised for manipulation of the focusing optics. This is based on a variable-length continuum manipulator. The latter enables movements of the endoscopic end effector in five degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the robot are integrated into a modular framework that is evaluated experimentally. The manipulation of focused laser radiation also requires precise adjustment of the focal position on the tissue. For this purpose, visual, haptic and visual-haptic assistance functions are presented. These support the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic assistance are demonstrated in a user study. The system performance and usability of the overall robotic system are assessed in an additional user study. Analogous to a clinical scenario, the subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergeführten Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die Bildgebung, die Planung und Ausführung der Laserablation sowie intraoperative Bewegungen des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen für die endoskopische Applikation fokussierter Laserstrahlung verfügbar. Ebenfalls sind keine Systeme bekannt, die Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausführung einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fünf Freiheitsgraden. Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen einen positiven Effekt der Automationskonzepte für die kontaktfreie Laserchirurgie
    • …
    corecore