4,651 research outputs found

    Southern Adventist University Undergraduate Catalog 2023-2024

    Get PDF
    Southern Adventist University\u27s undergraduate catalog for the academic year 2023-2024.https://knowledge.e.southern.edu/undergrad_catalog/1123/thumbnail.jp

    Une méthode de mesure du mouvement humain pour la programmation par démonstration

    Full text link
    Programming by demonstration (PbD) is an intuitive approach to impart a task to a robot from one or several demonstrations by the human teacher. The acquisition of the demonstrations involves the solution of the correspondence problem when the teacher and the learner differ in sensing and actuation. Kinesthetic guidance is widely used to perform demonstrations. With such a method, the robot is manipulated by the teacher and the demonstrations are recorded by the robot's encoders. In this way, the correspondence problem is trivial but the teacher dexterity is afflicted which may impact the PbD process. Methods that are more practical for the teacher usually require the identification of some mappings to solve the correspondence problem. The demonstration acquisition method is based on a compromise between the difficulty of identifying these mappings, the level of accuracy of the recorded elements and the user-friendliness and convenience for the teacher. This thesis proposes an inertial human motion tracking method based on inertial measurement units (IMUs) for PbD for pick-and-place tasks. Compared to kinesthetic guidance, IMUs are convenient and easy to use but can present a limited accuracy. Their potential for PbD applications is investigated. To estimate the trajectory of the teacher's hand, 3 IMUs are placed on her/his arm segments (arm, forearm and hand) to estimate their orientations. A specific method is proposed to partially compensate the well-known drift of the sensor orientation estimation around the gravity direction by exploiting the particular configuration of the demonstration. This method, called heading reset, is based on the assumption that the sensor passes through its original heading with stationary phases several times during the demonstration. The heading reset is implemented in an integration and vector observation algorithm. Several experiments illustrate the advantages of this heading reset. A comprehensive inertial human hand motion tracking (IHMT) method for PbD is then developed. It includes an initialization procedure to estimate the orientation of each sensor with respect to the human arm segment and the initial orientation of the sensor with respect to the teacher attached frame. The procedure involves a rotation and a static position of the extended arm. The measurement system is thus robust with respect to the positioning of the sensors on the segments. A procedure for estimating the position of the human teacher relative to the robot and a calibration procedure for the parameters of the method are also proposed. At the end, the error of the human hand trajectory is measured experimentally and is found in an interval between 28.528.5 mm and 61.861.8 mm. The mappings to solve the correspondence problem are identified. Unfortunately, the observed level of accuracy of this IHMT method is not sufficient for a PbD process. In order to reach the necessary level of accuracy, a method is proposed to correct the hand trajectory obtained by IHMT using vision data. A vision system presents a certain complementarity with inertial sensors. For the sake of simplicity and robustness, the vision system only tracks the objects but not the teacher. The correction is based on so-called Positions Of Interest (POIs) and involves 3 steps: the identification of the POIs in the inertial and vision data, the pairing of the hand POIs to objects POIs that correspond to the same action in the task, and finally, the correction of the hand trajectory based on the pairs of POIs. The complete method for demonstration acquisition is experimentally evaluated in a full PbD process. This experiment reveals the advantages of the proposed method over kinesthesy in the context of this work.La programmation par démonstration est une approche intuitive permettant de transmettre une tâche à un robot à partir d'une ou plusieurs démonstrations faites par un enseignant humain. L'acquisition des démonstrations nécessite cependant la résolution d'un problème de correspondance quand les systèmes sensitifs et moteurs de l'enseignant et de l'apprenant diffèrent. De nombreux travaux utilisent des démonstrations faites par kinesthésie, i.e., l'enseignant manipule directement le robot pour lui faire faire la tâche. Ce dernier enregistre ses mouvements grâce à ses propres encodeurs. De cette façon, le problème de correspondance est trivial. Lors de telles démonstrations, la dextérité de l'enseignant peut être altérée et impacter tout le processus de programmation par démonstration. Les méthodes d'acquisition de démonstration moins invalidantes pour l'enseignant nécessitent souvent des procédures spécifiques pour résoudre le problème de correspondance. Ainsi l'acquisition des démonstrations se base sur un compromis entre complexité de ces procédures, le niveau de précision des éléments enregistrés et la commodité pour l'enseignant. Cette thèse propose ainsi une méthode de mesure du mouvement humain par capteurs inertiels pour la programmation par démonstration de tâches de ``pick-and-place''. Les capteurs inertiels sont en effet pratiques et faciles à utiliser, mais sont d'une précision limitée. Nous étudions leur potentiel pour la programmation par démonstration. Pour estimer la trajectoire de la main de l'enseignant, des capteurs inertiels sont placés sur son bras, son avant-bras et sa main afin d'estimer leurs orientations. Une méthode est proposée afin de compenser partiellement la dérive de l'estimation de l'orientation des capteurs autour de la direction de la gravité. Cette méthode, appelée ``heading reset'', est basée sur l'hypothèse que le capteur passe plusieurs fois par son azimut initial avec des phases stationnaires lors d'une démonstration. Cette méthode est implémentée dans un algorithme d'intégration et d'observation de vecteur. Des expériences illustrent les avantages du ``heading reset''. Cette thèse développe ensuite une méthode complète de mesure des mouvements de la main humaine par capteurs inertiels (IHMT). Elle comprend une première procédure d'initialisation pour estimer l'orientation des capteurs par rapport aux segments du bras humain ainsi que l'orientation initiale des capteurs par rapport au repère de référence de l'humain. Cette procédure, consistant en une rotation et une position statique du bras tendu, est robuste au positionnement des capteurs. Une seconde procédure est proposée pour estimer la position de l'humain par rapport au robot et pour calibrer les paramètres de la méthode. Finalement, l'erreur moyenne sur la trajectoire de la main humaine est mesurée expérimentalement entre 28.5 mm et 61.8 mm, ce qui n'est cependant pas suffisant pour la programmation par démonstration. Afin d'atteindre le niveau de précision nécessaire, une nouvelle méthode est développée afin de corriger la trajectoire de la main par IHMT à partir de données issues d'un système de vision, complémentaire des capteurs inertiels. Pour maintenir une certaine simplicité et robustesse, le système de vision ne suit que les objets et pas l'enseignant. La méthode de correction, basée sur des ``Positions Of Interest (POIs)'', est constituée de 3 étapes: l'identification des POIs dans les données issues des capteurs inertiels et du système de vision, puis l'association de POIs liées à la main et de POIs liées aux objets correspondant à la même action, et enfin, la correction de la trajectoire de la main à partir des paires de POIs. Finalement, la méthode IHMT corrigée est expérimentalement évaluée dans un processus complet de programmation par démonstration. Cette expérience montre l'avantage de la méthode proposée sur la kinesthésie dans le contexte de ce travail

    Satellite remote sensing of surface winds, waves, and currents: Where are we now?

    Get PDF
    This review paper reports on the state-of-the-art concerning observations of surface winds, waves, and currents from space and their use for scientific research and subsequent applications. The development of observations of sea state parameters from space dates back to the 1970s, with a significant increase in the number and diversity of space missions since the 1990s. Sensors used to monitor the sea-state parameters from space are mainly based on microwave techniques. They are either specifically designed to monitor surface parameters or are used for their abilities to provide opportunistic measurements complementary to their primary purpose. The principles on which is based on the estimation of the sea surface parameters are first described, including the performance and limitations of each method. Numerous examples and references on the use of these observations for scientific and operational applications are then given. The richness and diversity of these applications are linked to the importance of knowledge of the sea state in many fields. Firstly, surface wind, waves, and currents are significant factors influencing exchanges at the air/sea interface, impacting oceanic and atmospheric boundary layers, contributing to sea level rise at the coasts, and interacting with the sea-ice formation or destruction in the polar zones. Secondly, ocean surface currents combined with wind- and wave- induced drift contribute to the transport of heat, salt, and pollutants. Waves and surface currents also impact sediment transport and erosion in coastal areas. For operational applications, observations of surface parameters are necessary on the one hand to constrain the numerical solutions of predictive models (numerical wave, oceanic, or atmospheric models), and on the other hand to validate their results. In turn, these predictive models are used to guarantee safe, efficient, and successful offshore operations, including the commercial shipping and energy sector, as well as tourism and coastal activities. Long-time series of global sea-state observations are also becoming increasingly important to analyze the impact of climate change on our environment. All these aspects are recalled in the article, relating to both historical and contemporary activities in these fields

    X-ICP: Localizability-Aware LiDAR Registration for Robust Localization in Extreme Environments

    Full text link
    Modern robotic systems are required to operate in challenging environments, which demand reliable localization under challenging conditions. LiDAR-based localization methods, such as the Iterative Closest Point (ICP) algorithm, can suffer in geometrically uninformative environments that are known to deteriorate point cloud registration performance and push optimization toward divergence along weakly constrained directions. To overcome this issue, this work proposes i) a robust fine-grained localizability detection module, and ii) a localizability-aware constrained ICP optimization module, which couples with the localizability detection module in a unified manner. The proposed localizability detection is achieved by utilizing the correspondences between the scan and the map to analyze the alignment strength against the principal directions of the optimization as part of its fine-grained LiDAR localizability analysis. In the second part, this localizability analysis is then integrated into the scan-to-map point cloud registration to generate drift-free pose updates by enforcing controlled updates or leaving the degenerate directions of the optimization unchanged. The proposed method is thoroughly evaluated and compared to state-of-the-art methods in simulated and real-world experiments, demonstrating the performance and reliability improvement in LiDAR-challenging environments. In all experiments, the proposed framework demonstrates accurate and generalizable localizability detection and robust pose estimation without environment-specific parameter tuning.Comment: 20 Pages, 20 Figures Submitted to IEEE Transactions On Robotics. Supplementary Video: https://youtu.be/SviLl7q69aA Project Website: https://sites.google.com/leggedrobotics.com/x-ic

    Proceedings of SIRM 2023 - The 15th European Conference on Rotordynamics

    Get PDF
    It was our great honor and pleasure to host the SIRM Conference after 2003 and 2011 for the third time in Darmstadt. Rotordynamics covers a huge variety of different applications and challenges which are all in the scope of this conference. The conference was opened with a keynote lecture given by Rainer Nordmann, one of the three founders of SIRM “Schwingungen in rotierenden Maschinen”. In total 53 papers passed our strict review process and were presented. This impressively shows that rotordynamics is relevant as ever. These contributions cover a very wide spectrum of session topics: fluid bearings and seals; air foil bearings; magnetic bearings; rotor blade interaction; rotor fluid interactions; unbalance and balancing; vibrations in turbomachines; vibration control; instability; electrical machines; monitoring, identification and diagnosis; advanced numerical tools and nonlinearities as well as general rotordynamics. The international character of the conference has been significantly enhanced by the Scientific Board since the 14th SIRM resulting on one hand in an expanded Scientific Committee which meanwhile consists of 31 members from 13 different European countries and on the other hand in the new name “European Conference on Rotordynamics”. This new international profile has also been emphasized by participants of the 15th SIRM coming from 17 different countries out of three continents. We experienced a vital discussion and dialogue between industry and academia at the conference where roughly one third of the papers were presented by industry and two thirds by academia being an excellent basis to follow a bidirectional transfer what we call xchange at Technical University of Darmstadt. At this point we also want to give our special thanks to the eleven industry sponsors for their great support of the conference. On behalf of the Darmstadt Local Committee I welcome you to read the papers of the 15th SIRM giving you further insight into the topics and presentations

    Technology for Low Resolution Space Based RSO Detection and Characterisation

    Get PDF
    Space Situational Awareness (SSA) refers to all activities to detect, identify and track objects in Earth orbit. SSA is critical to all current and future space activities and protect space assets by providing access control, conjunction warnings, and monitoring status of active satellites. Currently SSA methods and infrastructure are not sufficient to account for the proliferations of space debris. In response to the need for better SSA there has been many different areas of research looking to improve SSA most of the requiring dedicated ground or space-based infrastructure. In this thesis, a novel approach for the characterisation of RSO’s (Resident Space Objects) from passive low-resolution space-based sensors is presented with all the background work performed to enable this novel method. Low resolution space-based sensors are common on current satellites, with many of these sensors being in space using them passively to detect RSO’s can greatly augment SSA with out expensive infrastructure or long lead times. One of the largest hurtles to overcome with research in the area has to do with the lack of publicly available labelled data to test and confirm results with. To overcome this hurtle a simulation software, ORBITALS, was created. To verify and validate the ORBITALS simulator it was compared with the Fast Auroral Imager images, which is one of the only publicly available low-resolution space-based images found with auxiliary data. During the development of the ORBITALS simulator it was found that the generation of these simulated images are computationally intensive when propagating the entire space catalog. To overcome this an upgrade of the currently used propagation method, Specialised General Perturbation Method 4th order (SGP4), was performed to allow the algorithm to run in parallel reducing the computational time required to propagate entire catalogs of RSO’s. From the results it was found that the standard facet model with a particle swarm optimisation performed the best estimating an RSO’s attitude with a 0.66 degree RMSE accuracy across a sequence, and ~1% MAPE accuracy for the optical properties. This accomplished this thesis goal of demonstrating the feasibility of low-resolution passive RSO characterisation from space-based platforms in a simulated environment

    Beam scanning by liquid-crystal biasing in a modified SIW structure

    Get PDF
    A fixed-frequency beam-scanning 1D antenna based on Liquid Crystals (LCs) is designed for application in 2D scanning with lateral alignment. The 2D array environment imposes full decoupling of adjacent 1D antennas, which often conflicts with the LC requirement of DC biasing: the proposed design accommodates both. The LC medium is placed inside a Substrate Integrated Waveguide (SIW) modified to work as a Groove Gap Waveguide, with radiating slots etched on the upper broad wall, that radiates as a Leaky-Wave Antenna (LWA). This allows effective application of the DC bias voltage needed for tuning the LCs. At the same time, the RF field remains laterally confined, enabling the possibility to lay several antennas in parallel and achieve 2D beam scanning. The design is validated by simulation employing the actual properties of a commercial LC medium

    Autonomous Radar-based Gait Monitoring System

    Get PDF
    Features related to gait are fundamental metrics of human motion [1]. Human gait has been shown to be a valuable and feasible clinical marker to determine the risk of physical and mental functional decline [2], [3]. Technologies that detect changes in people’s gait patterns, especially older adults, could support the detection, evaluation, and monitoring of parameters related to changes in mobility, cognition, and frailty. Gait assessment has the potential to be leveraged as a clinical measurement as it is not limited to a specific health care discipline and is a consistent and sensitive test [4]. A wireless technology that uses electromagnetic waves (i.e., radar) to continually measure gait parameters at home or in a hospital without a clinician’s participation has been proposed as a suitable solution [3], [5]. This approach is based on the interaction between electromagnetic waves with humans and how their bodies impact the surrounding and scattered wireless signals. Since this approach uses wireless waves, people do not need to wear or carry a device on their bodies. Additionally, an electromagnetic wave wireless sensor has no privacy issues because there is no video-based camera. This thesis presents the design and testing of a radar-based contactless system that can monitor people’s gait patterns and recognize their activities in a range of indoor environments frequently and accurately. In this thesis, the use of commercially available radars for gait monitoring is investigated, which offers opportunities to implement unobtrusive and contactless gait monitoring and activity recognition. A novel fast and easy-to-implement gait extraction algorithm that enables an individual’s spatiotemporal gait parameter extraction at each gait cycle using a single FMCW (Frequency Modulated Continuous Wave) radar is proposed. The proposed system detects changes in gait that may be the signs of changes in mobility, cognition, and frailty, particularly for older adults in individual’s homes, retirement homes and long-term care facilities retirement homes. One of the straightforward applications for gait monitoring using radars is in corridors and hallways, which are commonly available in most residential homes, retirement, and long-term care homes. However, walls in the hallway have a strong “clutter” impact, creating multipath due to the wide beam of commercially available radar antennas. The multipath reflections could result in an inaccurate gait measurement because gait extraction algorithms employ the assumption that the maximum reflected signals come from the torso of the walking person (rather than indirect reflections or multipath) [6]. To address the challenges of hallway gait monitoring, two approaches were used: (1) a novel signal processing method and (2) modifying the radar antenna using a hyperbolic lens. For the first approach, a novel algorithm based on radar signal processing, unsupervised learning, and a subject detection, association and tracking method is proposed. This proposed algorithm could be paired with any type of multiple-input multiple-output (MIMO) or single-input multiple-output (SIMO) FMCW radar to capture human gait in a highly cluttered environment without needing radar antenna alteration. The algorithm functionality was validated by capturing spatiotemporal gait values (e.g., speed, step points, step time, step length, and step count) of people walking in a hallway. The preliminary results demonstrate the promising potential of the algorithm to accurately monitor gait in hallways, which increases opportunities for its applications in institutional and home environments. For the second approach, an in-package hyperbola-based lens antenna was designed that can be integrated with a radar module package empowered by the fast and easy-to-implement gait extraction method. The system functionality was successfully validated by capturing the spatiotemporal gait values of people walking in a hallway filled with metallic cabinets. The results achieved in this work pave the way to explore the use of stand-alone radar-based sensors in long hallways for day-to-day long-term monitoring of gait parameters of older adults or other populations. The possibility of the coexistence of multiple walking subjects is high, especially in long-term care facilities where other people, including older adults, might need assistance during walking. GaitRite and wearables are not able to assess multiple people’s gait at the same time using only one device [7], [8]. In this thesis, a novel radar-based algorithm is proposed that is capable of tracking multiple people or extracting walking speed of a participant with the coexistence of other people. To address the problem of tracking and monitoring multiple walking people in a cluttered environment, a novel iterative framework based on unsupervised learning and advanced signal processing was developed and tested to analyze the reflected radio signals and extract walking movements and trajectories in a hallway environment. Advanced algorithms were developed to remove multipath effects or ghosts created due to the interaction between walking subjects and stationary objects, to identify and separate reflected signals of two participants walking at a close distance, and to track multiple subjects over time. This method allows the extraction of walking speed in multiple closely-spaced subjects simultaneously, which is distinct from previous approaches where the speed of only one subject was obtained. The proposed multiple-people gait monitoring was assessed with 22 participants who participated in a bedrest (BR) study conducted at McGill University Health Centre (MUHC). The system functionality also was assessed for in-home applications. In this regard, a cloud-based system is proposed for non-contact, real-time recognition and monitoring of physical activities and walking periods within a domestic environment. The proposed system employs standalone Internet of Things (IoT)-based millimeter wave radar devices and deep learning models to enable autonomous, free-living activity recognition and gait analysis. Range-Doppler maps generated from a dataset of real-life in-home activities are used to train deep learning models. The performance of several deep learning models was evaluated based on accuracy and prediction time, with the gated recurrent network (GRU) model selected for real-time deployment due to its balance of speed and accuracy compared to 2D Convolutional Neural Network Long Short-Term Memory (2D-CNNLSTM) and Long Short-Term Memory (LSTM) models. In addition to recognizing and differentiating various activities and walking periods, the system also records the subject’s activity level over time, washroom use frequency, sleep/sedentary/active/out-of-home durations, current state, and gait parameters. Importantly, the system maintains privacy by not requiring the subject to wear or carry any additional devices
    • …
    corecore