Automated method and system for the evaluation of disease and registration accuracy in the subtraction of temporally sequential medical images
An apparatus, method and computer program product for performing computer aided diagnosis on temporal subtraction images of objects. A mode of a gray-level histogram is identified, and a gray-level threshold is established at a predefined fraction of this modal value. All pixels with gray levels below this threshold that lie within the lung regions of the temporal subtraction image remain "on," while all other pixels are set to zero. Area and circularity requirements are imposed to eliminate false-positive regions. Areas of pathologic change identified in this manner may be presented as outlines in the subtraction image or as highlighted regions in the original radiographic image so that, in effect, temporal subtraction becomes a "background" process for computer-aided diagnosis. The present invention is also directed to method, apparatus, and computer program product for performing temporal subtraction on energy subtraction images, with or without subsequent computer aided diagnosis, of objects
Feasibility of using Lodox to perform digital subtraction angiography
Bibliography: leaves 150-157.Many cases in trauma involve vessel imaging to determine integrity and the origin of lesions or blockages. Digital subtraction angiography (DSA) is a tool used to improve the clarity of the vessels being imaged for better and easier decision making in diagnostics and planning. Lodox, a low dose x-ray system developed by Debex (Pty) Ltd, a subsidiary of de Beers, was designed specifically for the trauma environment. It therefore follows that, if possible, a function so readily used in trauma, such as DSA, should be added to the imaging repertoire of an x-ray system designed for use in this environment. In this dissertation the feasibility of using Lodox to perform DSA is therefore explored. In doing so, the requirements of a trauma unit and the theory behind DSA were researched so as to obtain a better understanding into what would be required
Expert System with an Embedded Imaging Module for Diagnosing Lung Diseases
Lung diseases are one of the major causes of suffering and death in the world. Improved
survival rate could be obtained if the diseases can be detected at its early stage. Specialist
doctors with the expertise and experience to interpret medical images and diagnose
complex lung diseases are scarce. In this work, a rule-based expert system with an
embedded imaging module is developed to assist the general physicians in hospitals and
clinics to diagnose lung diseases whenever the services of specialist doctors are not
available. The rule-based expert system contains a large knowledge base of data from
various categories such as patient's personal and medical history, clinical symptoms,
clinical test results and radiological information. An imaging module is integrated into
the expert system for the enhancement of chest X-Ray images. The goal of this module is
to enhance the chest X-Ray images so that it can provide details similar to more
expensive methods such as MRl and CT scan. A new algorithm which is a modified
morphological grayscale top hat transform is introduced to increase the visibility of lung
nodules in chest X-Rays. Fuzzy inference technique is used to predict the probability of
malignancy of the nodules. The output generated by the expert system was compared
with the diagnosis made by the specialist doctors. The system is able to produce results\ud
which are similar to the diagnosis made by the doctors and is acceptable by clinical
standards
Development, Implementation and Pre-clinical Evaluation of Medical Image Computing Tools in Support of Computer-aided Diagnosis: Respiratory, Orthopedic and Cardiac Applications
Over the last decade, image processing tools have become crucial components of all clinical and research efforts involving medical imaging and associated applications. The imaging data available to the radiologists continue to increase their workload, raising the need for efficient identification and visualization of the required image data necessary for clinical assessment.
Computer-aided diagnosis (CAD) in medical imaging has evolved in response to the need for techniques that can assist the radiologists to increase throughput while reducing human error and bias without compromising the outcome of the screening, diagnosis or disease assessment. More intelligent, but simple, consistent and less time-consuming methods will become more widespread, reducing user variability, while also revealing information in a more clear, visual way.
Several routine image processing approaches, including localization, segmentation, registration, and fusion, are critical for enhancing and enabling the development of CAD techniques. However, changes in clinical workflow require significant adjustments and re-training and, despite the efforts of the academic research community to develop state-of-the-art algorithms and high-performance techniques, their footprint often hampers their clinical use.
Currently, the main challenge seems to not be the lack of tools and techniques for medical image processing, analysis, and computing, but rather the lack of clinically feasible solutions that leverage the already developed and existing tools and techniques, as well as a demonstration of the potential clinical impact of such tools. Recently, more and more efforts have been dedicated to devising new algorithms for localization, segmentation or registration, while their potential and much intended clinical use and their actual utility is dwarfed by the scientific, algorithmic and developmental novelty that only result in incremental improvements over already algorithms.
In this thesis, we propose and demonstrate the implementation and evaluation of several different methodological guidelines that ensure the development of image processing tools --- localization, segmentation and registration --- and illustrate their use across several medical imaging modalities --- X-ray, computed tomography, ultrasound and magnetic resonance imaging --- and several clinical applications:
Lung CT image registration in support for assessment of pulmonary nodule growth rate and disease progression from thoracic CT images.
Automated reconstruction of standing X-ray panoramas from multi-sector X-ray images for assessment of long limb mechanical axis and knee misalignment.
Left and right ventricle localization, segmentation, reconstruction, ejection fraction measurement from cine cardiac MRI or multi-plane trans-esophageal ultrasound images for cardiac function assessment.
When devising and evaluating our developed tools, we use clinical patient data to illustrate the inherent clinical challenges associated with highly variable imaging data that need to be addressed before potential pre-clinical validation and implementation.
In an effort to provide plausible solutions to the selected applications, the proposed methodological guidelines ensure the development of image processing tools that help achieve sufficiently reliable solutions that not only have the potential to address the clinical needs, but are sufficiently streamlined to be potentially translated into eventual clinical tools provided proper implementation.
G1: Reducing the number of degrees of freedom (DOF) of the designed tool, with a plausible example being avoiding the use of inefficient non-rigid image registration methods. This guideline addresses the risk of artificial deformation during registration and it clearly aims at reducing complexity and the number of degrees of freedom.
G2: The use of shape-based features to most efficiently represent the image content, either by using edges instead of or in addition to intensities and motion, where useful. Edges capture the most useful information in the image and can be used to identify the most important image features. As a result, this guideline ensures a more robust performance when key image information is missing.
G3: Efficient method of implementation. This guideline focuses on efficiency in terms of the minimum number of steps required and avoiding the recalculation of terms that only need to be calculated once in an iterative process. An efficient implementation leads to reduced computational effort and improved performance.
G4: Commence the workflow by establishing an optimized initialization and gradually converge toward the final acceptable result. This guideline aims to ensure reasonable outcomes in consistent ways and it avoids convergence to local minima, while gradually ensuring convergence to the global minimum solution.
These guidelines lead to the development of interactive, semi-automated or fully-automated approaches that still enable the clinicians to perform final refinements, while they reduce the overall inter- and intra-observer variability, reduce ambiguity, increase accuracy and precision, and have the potential to yield mechanisms that will aid with providing an overall more consistent diagnosis in a timely fashion
Full-resolution Lung Nodule Segmentation from Chest X-ray Images using Residual Encoder-Decoder Networks
Lung cancer is the leading cause of cancer death and early diagnosis is
associated with a positive prognosis. Chest X-ray (CXR) provides an inexpensive
imaging mode for lung cancer diagnosis. Suspicious nodules are difficult to
distinguish from vascular and bone structures using CXR. Computer vision has
previously been proposed to assist human radiologists in this task, however,
leading studies use down-sampled images and computationally expensive methods
with unproven generalization. Instead, this study localizes lung nodules using
efficient encoder-decoder neural networks that process full resolution images
to avoid any signal loss resulting from down-sampling. Encoder-decoder networks
are trained and tested using the JSRT lung nodule dataset. The networks are
used to localize lung nodules from an independent external CXR dataset.
Sensitivity and false positive rates are measured using an automated framework
to eliminate any observer subjectivity. These experiments allow for the
determination of the optimal network depth, image resolution and pre-processing
pipeline for generalized lung nodule localization. We find that nodule
localization is influenced by subtlety, with more subtle nodules being detected
in earlier training epochs. Therefore, we propose a novel self-ensemble model
from three consecutive epochs centered on the validation optimum. This ensemble
achieved a sensitivity of 85% in 10-fold internal testing with false positives
of 8 per image. A sensitivity of 81% is achieved at a false positive rate of 6
following morphological false positive reduction. This result is comparable to
more computationally complex systems based on linear and spatial filtering, but
with a sub-second inference time that is faster than other methods. The
proposed algorithm achieved excellent generalization results against an
external dataset with sensitivity of 77% at a false positive rate of 7.6
New technology in radiological diagnosis: An investigation of diagnostic image quality in digital displays of radiographs
Digital radiology is undergoing rapid evolution. Its objectives can be summarized as the creation within the modern radiology department - and indeed within the entire hospital - of a harmonious, integrated, electronic network capable of handling all diagnostic radiological images, obviating the need for conventional film-based radiology. One of the limiting factors in the introduction and exploitation of digital technology is the issue of image display quality: if electronic display systems are to be widely used for primary radiological diagnosis, it is essential that the diagnostic quality of the displayed images should not be compromised. From the perspective of the practising radiologist, this study examines the performance of the first two commercially available digital radiological display systems to be purchased and installed in a British hospital. This work incorporates an extensive observer performance investigation of image quality from existing 1024- and 1280-line display systems, and suggests that displayed images digitized at a pixel size of 210?m show a significant reduction in diagnostic performance when compared with original film. Such systems appear to be unsuitable for primary radiological diagnosis of subtle lesions. Some of the physical properties of such systems, some relevant methodological issues, and the relationship between image quality and other factors influencing the development acceptance and implementation of digital technology, have also been investigated; the results are presented. This is a controversial subject, and conflicting views have been expressed in the British literature concerning the issue of whether or not the technology is now ready for total system implementation; the view of this author is that careful testing of display systems, and of every other component of digital networks, should precede their entry into clinical use
- …