2,631 research outputs found

    EEG Artifact Removal in TMS Studies of Cortical Speech Areas

    Get PDF
    The combination of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) is commonly applied for studying the effective connectivity of neuronal circuits. The stimulation excites neurons, and the resulting TMS-evoked potentials (TEPs) are recorded with EEG. A serious obstacle in this method is the generation of large muscle artifacts from scalp muscles, especially when frontolateral and temporoparietal, such as speech, areas are stimulated. Here, TMS–EEG data were processed with the signal-space projection and source-informed reconstruction (SSP–SIR) artifact-removal methods to suppress these artifacts. SSP–SIR suppressed muscle artifacts according to the difference in frequency contents of neuronal signals and muscle activity. The effectiveness of SSP–SIR in rejecting muscle artifacts and the degree of excessive attenuation of brain EEG signals were investigated by comparing the processed versions of the recorded TMS–EEG data with simulated data. The calculated individual lead-field matrix describing how the brain signals spread on the cortex were used as simulated data. We conclude that SSP–SIR was effective in suppressing artifacts also when frontolateral and temporoparietal cortical sites were stimulated, but it may have suppressed also the brain signals near the stimulation site. Effective connectivity originating from the speech-related areas may be studied even when speech areas are stimulated at least on the contralateral hemisphere where the signals were not suppressed that much.Peer reviewe

    Removal of Muscle Artifacts from Single-Channel EEG Based on Ensemble Empirical Mode Decomposition and Multiset Canonical Correlation Analysis

    Get PDF
    Electroencephalogram (EEG) recordings are often contaminated with muscle artifacts. This disturbing muscular activity strongly affects the visual analysis of EEG and impairs the results of EEG signal processing such as brain connectivity analysis. If multichannel EEG recordings are available, then there exist a considerable range of methods which can remove or to some extent suppress the distorting effect of such artifacts. Yet to our knowledge, there is no existing means to remove muscle artifacts from single-channel EEG recordings. Moreover, considering the recently increasing need for biomedical signal processing in ambulatory situations, it is crucially important to develop single-channel techniques. In this work, we propose a simple, yet effective method to achieve the muscle artifact removal from single-channel EEG, by combining ensemble empirical mode decomposition (EEMD) with multiset canonical correlation analysis (MCCA). We demonstrate the performance of the proposed method through numerical simulations and application to real EEG recordings contaminated with muscle artifacts. The proposed method can successfully remove muscle artifacts without altering the recorded underlying EEG activity. It is a promising tool for real-world biomedical signal processing applications

    Artifact Rejection Methodology Enables Continuous, Noninvasive Measurement of Gastric Myoelectric Activity in Ambulatory Subjects.

    Get PDF
    The increasing prevalence of functional and motility gastrointestinal (GI) disorders is at odds with bottlenecks in their diagnosis, treatment, and follow-up. Lack of noninvasive approaches means that only specialized centers can perform objective assessment procedures. Abnormal GI muscular activity, which is coordinated by electrical slow-waves, may play a key role in symptoms. As such, the electrogastrogram (EGG), a noninvasive means to continuously monitor gastric electrical activity, can be used to inform diagnoses over broader populations. However, it is seldom used due to technical issues: inconsistent results from single-channel measurements and signal artifacts that make interpretation difficult and limit prolonged monitoring. Here, we overcome these limitations with a wearable multi-channel system and artifact removal signal processing methods. Our approach yields an increase of 0.56 in the mean correlation coefficient between EGG and the clinical "gold standard", gastric manometry, across 11 subjects (p < 0.001). We also demonstrate this system's usage for ambulatory monitoring, which reveals myoelectric dynamics in response to meals akin to gastric emptying patterns and circadian-related oscillations. Our approach is noninvasive, easy to administer, and has promise to widen the scope of populations with GI disorders for which clinicians can screen patients, diagnose disorders, and refine treatments objectively

    Transcranial magnetic stimulation and EEG in studies of brain function

    Get PDF
    Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) is a multimodal technique, with a temporal resolution of submilliseconds, for studying cortical excitability and connectivity. When TMS is combined with neuronavigation, resulting in so-called navigated TMS (nTMS), the technique becomes very powerful. However, despite the potential of TMS–EEG, its use for studying lateral areas has been restricted because the TMS pulse induces strong muscle artifacts, making the EEG data useless for further analyses. In this Thesis, methods for analyzing TMS-evoked EEG data from lateral areas are introduced. First, TMS–EEG is used to study Broca's area and dorsal premotor cortex. Due to the fact that those areas are close to cranial muscles, their stimulation evokes large muscle artifacts in EEG recordings. The behavior of the artifacts is described in detail. Two approaches to deal with large artifacts are presented. In the first approach, independent component analysis (ICA) is used. Here, FastICA algorithm is modified to make the search of the components more robust and easier, allowing one to get more stable results. The second approach presents methods for suppressing the artifacts rather than removing them. These methods were combined with source localization showing that the artifact suppression is efficient. The methods were tested with both real and simulated data, suggesting they are useful for artifact correction. For a better understanding of the effects of repetitive nTMS during naming tasks and the cortical organization of speech in general, here another study is introduced to understand the sensitivity of object and action naming tasks to repetitive nTMS. The distributions of cortical sites, where repetitive nTMS produced naming errors during both tasks, are compared. Thus, it is shown how this study can impact on both cognitive neuroscience and clinical practice. In the last part, the beamformer method is improved to study source localization, which makes it a robust method to study time-correlated sources. In this Thesis, I discuss how all these methods together can contribute to study brain connectivity of language and lateral areas with TMS–EEG, opening new possibilities for basic research and clinical applications

    Comparative analysis of TMS-EEG signal using different approaches in healthy subjects

    Get PDF
    openThe integration of transcranial magnetic stimulation with electroencephalography (TMS-EEG) represents a useful non-invasive approach to assess cortical excitability, plasticity and intra-cortical connectivity in humans in physiological and pathological conditions. However, biological and environmental noise sources can contaminate the TMS-evoked potentials (TEPs). Therefore, signal preprocessing represents a fundamental step in the analysis of these potentials and is critical to remove artefactual components while preserving the physiological brain activity. The objective of the present study is to evaluate the effects of different signal processing pipelines, (namely Leodori et al., Rogasch et al., Mutanen et al.) applied on TEPs recorded in five healthy volunteers after TMS stimulation of the primary motor cortex (M1) of the dominant hemisphere. These pipelines were used and compared to remove artifacts and improve the quality of the recorded signals, laying the foundation for subsequent analyses. Various algorithms, such as Independent Component Analysis (ICA), SOUND, and SSP-SIR, were used in each pipeline. Furthermore, after signal preprocessing, current localization was performed to map the TMS-induced neural activation in the cortex. This methodology provided valuable information on the spatial distribution of activity and further validated the effectiveness of the signal cleaning pipelines. Comparing the effects of the different pipelines on the same dataset, we observed considerable variability in how the pipelines affect various signal characteristics. We observed significant differences in the effects on signal amplitude and in the identification and characterisation of peaks of interest, i.e., P30, N45, P60, N100, P180. The identification and characteristics of these peaks showed variability, especially with regard to the early peaks, which reflect the cortical excitability of the stimulated area and are the more affected by biological and stimulation-related artifacts. Despite these differences, the topographies and source localisation, which are the most informative and useful in reconstructing signal dynamics, were consistent and reliable between the different pipelines considered. The results suggest that the existing methodologies for analysing TEPs produce different effects on the data, but are all capable of reproducing the dynamics of the signal and its components. Future studies evaluating different signal preprocessing methods in larger populations are needed to determine an appropriate workflow that can be shared through the scientific community, in order to make the results obtained in different centres comparable
    • …
    corecore