576 research outputs found

    Using the Microsoft Kinect to assess human bimanual coordination

    Get PDF
    Optical marker-based systems are the gold-standard for capturing three-dimensional (3D) human kinematics. However, these systems have various drawbacks including time consuming marker placement, soft tissue movement artifact, and are prohibitively expensive and non-portable. The Microsoft Kinect is an inexpensive, portable, depth camera that can be used to capture 3D human movement kinematics. Numerous investigations have assessed the Kinect\u27s ability to capture postural control and gait, but to date, no study has evaluated it\u27s capabilities for measuring spatiotemporal coordination. In order to investigate human coordination and coordination stability with the Kinect, a well-studied bimanual coordination paradigm (Kelso, 1984, Kelso; Scholz, & Schöner, 1986) was adapted. ^ Nineteen participants performed ten trials of coordinated hand movements in either in-phase or anti-phase patterns of coordination to the beat of a metronome which was incrementally sped up and slowed down. Continuous relative phase (CRP) and the standard deviation of CRP were used to assess coordination and coordination stability, respectively.^ Data from the Kinect were compared to a Vicon motion capture system using a mixed-model, repeated measures analysis of variance and intraclass correlation coefficients (2,1) (ICC(2,1)).^ Kinect significantly underestimated CRP for the the anti-phase coordination pattern (p \u3c.0001) and overestimated the in-phase pattern (p\u3c.0001). However, a high ICC value (r=.097) was found between the systems. For the standard deviation of CRP, the Kinect exhibited significantly higher variability than the Vicon (p \u3c .0001) but was able to distinguish significant differences between patterns of coordination with anti-phase variability being higher than in-phase (p \u3c .0001). Additionally, the Kinect was unable to accurately capture the structure of coordination stability for the anti-phase pattern. Finally, agreement was found between systems using the ICC (r=.37).^ In conclusion, the Kinect was unable to accurately capture mean CRP. However, the high ICC between the two systems is promising and the Kinect was able to distinguish between the coordination stability of in-phase and anti-phase coordination. However, the structure of variability as movement speed increased was dissimilar to the Vicon, particularly for the anti-phase pattern. Some aspects of coordination are nicely captured by the Kinect while others are not. Detecting differences between bimanual coordination patterns and the stability of those patterns can be achieved using the Kinect. However, researchers interested in the structure of coordination stability should exercise caution since poor agreement was found between systems

    Validation of joint angle measurements: comparison of a novel low cost marker-less system with an industry standard marker-based system

    Get PDF
    Human motion tracking is widely used for assessment of movement dysfunction in orthopaedic patients. Currently, most clinical motion analysis centres use marker based three-dimensional (3D) systems as they are deemed to be the most accurate method. However, due to space, costs and logistics they are not available in many clinical settings. This study compared joint angles measured in functional tests using the novel low-cost Microsoft Kinect Perfect Phorm system with the established marker based Nexus VICON system. When measuring right and left knee flexion, the average difference between the VICON and Kinect Perfect Phorm measurement was 13.2%, with a SD of 19.6. Both overestimation and underestimation of the joint angle was recorded in different participants. Although the average percentage difference during hip abduction tests was lower at -3.9%, the range of error was far greater (SD=75). From this, it can be concluded that the level of accuracy presented in the new low cost Kinect Perfect Phorm system is not yet suitable for clinical assessments. However, for general tests of performance, and for tracking cases where absolute accuracy is less critical, future versions of this software may have a place

    Can shoulder range of movement be measured accurately using the Microsoft Kinect sensor plus Medical Interactive Recovery Assistant (MIRA) software?

    Get PDF
    BackgroundThis study compared the accuracy of measuring shoulder range of movement (ROM) with a simple laptop-sensor combination vs. trained observers (shoulder physiotherapists and shoulder surgeons) using motion capture (MoCap) laboratory equipment as the gold standard. MethodsThe Microsoft Kinect sensor (Microsoft Corp., Redmond, WA, USA) tracks 3-dimensional human motion. Ordinarily used with an Xbox (Microsoft Corp.) video game console, Medical Interactive Recovery Assistant (MIRA) software (MIRA Rehab Ltd., London, UK) allows this small sensor to measure shoulder movement with a standard computer. Shoulder movements of 49 healthy volunteers were simultaneously measured by trained observers, MoCap, and the MIRA device. Internal rotation was assessed with the shoulder abducted 90° and external rotation with the shoulder adducted. Visual estimation and MIRA measurements were compared with gold standard MoCap measurements for agreement using Bland-Altman methods. Results There were 1670 measurements analyzed. The MIRA evaluations of all 4 cardinal shoulder movements were significantly more precise, with narrower limits of agreement, than the measurements of trained observers. MIRA achieved ±11° (95% confidence interval [CI], 8.7°-12.6°) for forward flexion vs. ±16° (95% CI, 14.6°-17.6°) by trained observers. For abduction, MIRA showed ±11° (95% CI, 8.7°-12.8°) against ±15° (95% CI, 13.4°-16.2°) for trained observers. MIRA attained ±10° (95% CI, 8.1°-11.9°) during external rotation measurement, whereas trained observers only reached ±21° (95% CI, 18.7°-22.6°). For internal rotation, MIRA achieved ±9° (95% CI, 7.2°-10.4°), which was again better than TOs at ±18° (95% CI, 16.0°-19.3°). ConclusionsA laptop combined with a Microsoft Kinect sensor and the MIRA software can measure shoulder movements with acceptable levels of accuracy. This technology, which can be easily set up, may also allow precise shoulder ROM measurement outside the clinic setting

    Computer Vision Solutions for Range of Motion Assessment

    Get PDF
    Joint range of motion (ROM) is an important indicator of physical functionality and musculoskeletal health. In sports, athletes require adequate levels of joint mobility to minimize the risk of injuries and maximize performance, while in rehabilitation, restoring joint ROM is essential for faster recovery and improved physical function. Traditional methods for measuring ROM include goniometry, inclinometry and visual estimation; all of which are limited in accuracy due to the subjective nature of the assessment. With the rapid development of technology, new systems based on computer vision are continuously introduced as a possible solution for more objective and accurate measurements of the range of motion. Therefore, this article aimed to evaluate novel computer vision-based systems based on their accuracy and practical applicability for a range of motion assessment. The review covers a variety of systems, including motion-capture systems (2D and 3D cameras), RGB-Depth cameras, commercial software systems and smartphone apps. Furthermore, this article also highlights the potential limitations of these systems and explores their potential future applications in sports and rehabilitation

    Markerless measurement techniques for motion analysis in sports science

    Get PDF
    Markerless motion capture system and X-ray fluoroscopy as two markerless measurement systems were introduced to the application method in sports biomechanical areas. An overview of the technological process, data accuracy, suggested movements, and recommended body parts were explained. The markerless motion capture system consists of four parts: camera, body model, image feature, and algorithms. Even though the markerless motion capture system seems promising, it is not yet known whether these systems can be used to achieve the required accuracy and whether they can be appropriately used in sports biomechanics and clinical research. The biplane fluoroscopy technique analyzes motion data by collecting, image calibrating, and processing, which is effective for determining small joint kinematic changes and calculating joint angles. The method was used to measure walking and jumping movements primarily because of the experimental conditions and mainly to detect the data of lower limb joints

    El uso de la tecnología de captura de movimiento para el análisis del rendimiento deportivo

    Get PDF
    In sport performance, motion capture aims at tracking and recording athletes’ human motion in real time to analyze physical condition, athletic performance, technical expertise and injury mechanism, prevention and rehabilitation. The aim of this paper is to systematically review the latest developments of motion capture systems for the analysis of sport performance. To that end, selected keywords were searched on studies published in the last four years in the electronic databases ISI Web of Knowledge, Scopus, PubMed and SPORTDiscus, which resulted in 892 potential records. After duplicate removal and screening of the remaining records, 81 journal papers were retained for inclusion in this review, distributed as 53 records for optical systems, 15 records for non-optical systems and 13 records for markerless systems. Resultant records were screened to distribute them according to the following analysis categories: biomechanical motion analysis, validation of new systems and performance enhancement. Although optical systems are regarded as golden standard with accurate results, the cost of equipment and time needed to capture and postprocess data have led researchers to test other technologies. First, non-optical systems rely on attaching sensors to body parts to send their spatial information to computer wirelessly by means of different technologies, such as electromagnetic and inertial (accelerometry). Finally, markerless systems are adequate for free, unobstructive motion analysis since no attachment is carried by athletes. However, more sensors and sophisticated signal processing must be used to increase the expected level of accuracy.En el ámbito del rendimiento deportivo, el objetivo de la captura de movimiento es seguir y registrar el movimiento humano de deportistas para analizar su condición física, rendimiento, técnica y el origen, prevención y rehabilitación de lesiones. En este artículo, se realiza una revisión sistemática de los últimos avances en sistemas de captura de movimiento para el análisis del rendimiento deportivo. Para ello, se buscaron palabras clave en estudios publicados en los últimos cuatro años en las bases de datos electrónicas ISI Web of Knowledge, Scopus, PubMed y SPORTDiscus, dando lugar a 892 registros. Tras borrar duplicados y análisis del resto, se seleccionaron 81 artículos de revista, distribuidos en 53 registros para sistemas ópticos, 15 para sistemas no ópticos y 13 para sistemas sin marcadores. Los registros se clasificaron según las categorías: análisis biomecánico, validación de nuevos sistemas y mejora del rendimiento. Aunque los sistemas ópticos son los sistemas de referencia por su precisión, el coste del equipamiento y el tiempo invertido en la captura y postprocesado ha llevado a los investigadores a probar otras tecnologías. En primer lugar, los sistemas no ópticos se basan en adherir sensores a zonas corporales para mandar su información espacial a un ordenador mediante distintas tecnologías, tales como electromagnética y inercial (acelerometría). Finalmente, los sistemas sin marcadores permiten un análisis del movimiento sin restricciones ya que los deportistas no llevan adherido ningún elemento. Sin embargo, se necesitan más sensores y un procesado de señal avanzado para aumentar el nivel de precisión necesario

    Can shoulder range of movement be measured accurately using the Microsoft Kinect sensor plus Medical Interactive Recovery Assistant software?

    Get PDF
    © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Background: This study compared the accuracy of measuring shoulder range of movement (ROM) with a simple laptop-sensor combination vs. trained observers (shoulder physiotherapists and shoulder surgeons) using motion capture (MoCap) laboratory equipment as the gold standard. Methods: The Microsoft Kinect sensor (Microsoft Corp., Redmond, WA, USA) tracks 3-dimensional human motion. Ordinarily used with an Xbox (Microsoft Corp.) video game console, Medical Interactive Recovery Assistant (MIRA) software (MIRA Rehab Ltd., London, UK) allows this small sensor to measure shoulder movement with a standard computer. Shoulder movements of 49 healthy volunteers were simultaneously measured by trained observers, MoCap, and the MIRA device. Internal rotation was assessed with the shoulder abducted 90° and external rotation with the shoulder adducted. Visual estimation and MIRA measurements were compared with gold standard MoCap measurements for agreement using Bland-Altman methods. Results: There were 1670 measurements analyzed. The MIRA evaluations of all 4 cardinal shoulder movements were significantly more precise, with narrower limits of agreement, than the measurements of trained observers. MIRA achieved ±11° (95% confidence interval [CI], 8.7°-12.6°) for forward flexion vs. ±16° (95% CI, 14.6°-17.6°) by trained observers. For abduction, MIRA showed ±11° (95% CI, 8.7°-12.8°) against ±15° (95% CI, 13.4°-16.2°) for trained observers. MIRA attained ±10° (95% CI, 8.1°-11.9°) during external rotation measurement, whereas trained observers only reached ±21° (95% CI, 18.7°-22.6°). For internal rotation, MIRA achieved ±9° (95% CI, 7.2°-10.4°), which was again better than TOs at ±18° (95% CI, 16.0°-19.3°). Conclusions: A laptop combined with a Microsoft Kinect sensor and the MIRA software can measure shoulder movements with acceptable levels of accuracy. This technology, which can be easily set up, may also allow precise shoulder ROM measurement outside the clinic setting

    A depth camera motion analysis framework for tele-rehabilitation : motion capture and person-centric kinematics analysis

    Get PDF
    With increasing importance given to telerehabilitation, there is a growing need for accurate, low-cost, and portable motion capture systems that do not require specialist assessment venues. This paper proposes a novel framework for motion capture using only a single depth camera, which is portable and cost effective compared to most industry-standard optical systems, without compromising on accuracy. Novel signal processing and computer vision algorithms are proposed to determine motion patterns of interest from infrared and depth data. In order to demonstrate the proposed framework’s suitability for rehabilitation, we developed a gait analysis application that depends on the underlying motion capture sub-system. Each subject’s individual kinematics parameters, which are unique to that subject, are calculated and these are stored for monitoring individual progress of the clinical therapy. Experiments were conducted on 14 different subjects, 5 healthy and 9 stroke survivors. The results show very close agreement of the resulting relevant joint angles with a 12-camera based VICON system, a mean error of at most 1.75% in detecting gait events w.r.t the manually generated ground-truth, and significant performance improvements in terms of accuracy and execution time compared to a previous Kinect-based system
    corecore