4,000 research outputs found

    A Hybrid-Powered Wireless System for Multiple Biopotential Monitoring

    Get PDF
    Chronic diseases are the top cause of human death in the United States and worldwide. A huge amount of healthcare costs is spent on chronic diseases every year. The high medical cost on these chronic diseases facilitates the transformation from in-hospital to out-of-hospital healthcare. The out-of-hospital scenarios require comfortability and mobility along with quality healthcare. Wearable electronics for well-being management provide good solutions for out-of-hospital healthcare. Long-term health monitoring is a practical and effective way in healthcare to prevent and diagnose chronic diseases. Wearable devices for long-term biopotential monitoring are impressive trends for out-of-hospital health monitoring. The biopotential signals in long-term monitoring provide essential information for various human physiological conditions and are usually used for chronic diseases diagnosis. This study aims to develop a hybrid-powered wireless wearable system for long-term monitoring of multiple biopotentials. For the biopotential monitoring, the non-contact electrodes are deployed in the wireless wearable system to provide high-level comfortability and flexibility for daily use. For providing the hybrid power, an alternative mechanism to harvest human motion energy, triboelectric energy harvesting, has been applied along with the battery to supply energy for long-term monitoring. For power management, an SSHI rectifying strategy associated with triboelectric energy harvester design has been proposed to provide a new perspective on designing TEHs by considering their capacitance concurrently. Multiple biopotentials, including ECG, EMG, and EEG, have been monitored to validate the performance of the wireless wearable system. With the investigations and studies in this project, the wearable system for biopotential monitoring will be more practical and can be applied in the real-life scenarios to increase the economic benefits for the health-related wearable devices

    Conception, development and evaluation of polymer-based screen-printed textile electrodes for biopotential monitoring

    Get PDF
    Wearable technologies represent the new frontier of vital signs monitoring in different applications, from fitness to health. With the progressive miniaturization of the electronic components, enabling the implementation of portable and hand-held acquisition and recording devices, the research focus has shifted toward the development of effective and unobtrusive textile electrodes. This work deals with the study, development and characterization of organic-polymer-based electrodes for biopotentials. After an overview of the main materials and fabrication technologies presented so far in the scientific literature, the possibility to use these electrodes as an alternative to the Ag/AgCl disposable gelled electrodes usually adopted in clinical practice was tested. For this purpose, several textile electrode realization techniques were studied and optimized, in order to create electrodes with adequate features to detect two fundamental physiological signals: the electrocardiogram (ECG) and the electromyogram (EMG). The electrodes were obtained by depositing on the fabric the organic bio-compatible polymer poly(3,4-ethylenedioxythiophene) doped with poly(4-styrenesulfonate) (PEDOT:PSS) with three deposition procedures: dipcoating, ink-jet printing and screen printing. The physical\u2013chemical properties of the polymer solution were varied for each procedure to obtain an optimal and reproducible result. For what concerns the ECG signal, the research activity focused on screen-printed textile electrodes and their performance was first assessed by benchtop measurements and then by human trials. The first tests demonstrated that, by adding solid or liquid electrolytes the electrodes, the largest part of the characteristics required by the ANSI/AAMI EC12:2000 standard for gelled ECG electrodes can be achieved. Tests performed in different conditions showed that the skin contact impedance and the ECG morphological features are highly similar to those obtainable with disposable gelled Ag/AgCl electrodes (\u3c1 > 0.99). A trial with ten subjects revealed also the capability of the proposed electrodes to accurately capture with clinical instruments an ECG morphology with performance comparable to off-the-shelf disposable electrodes. Furthermore, the proposed textile electrodes preserve their electrical properties and functionality even after several mild washing cycles, while they suffered physical stretching. Similar tests were performed on screen-printed textile electrodes fabricated in two different sizes to test them as EMG sensors, with and without electrolytes. After a series of controlled acquisitions performed by electro-stimulating the muscles in order to analyze the waveform morphologu of the M-wave, the statistical analysis showed a high similarity in terms of rms of the noise and electrode-skin impedance between conventional and textile electrodes with the addition of solid hydrogel and saline solution. Furthermore, the M-wave recorded on the tibialis anterior muscle during the stimulation of the peroneal nerve was comparatively analyzed between conventional and textile electrodes. The comparison provided an R2 value higher than 97% in all measurement conditions. These results opened their use in smart garments for real application scenarios and for this purpose were developed a couple of smart shirts able to detect the EGC and the EMG signal. The results indicated that this approach could be adopted in the future for the development of smart garments able to comfortably detect physiological signals

    Smart Device for the Determination of Heart Rate Variability in Real Time

    Get PDF
    This work presents a first approach to the design, development, and implementation of a smart device for the real-time measurement and detection of alterations in heart rate variability (HRV). The smart device follows a modular design scheme, which consists of an electrocardiogram (ECG) signal acquisition module, a processing module and a wireless communications module. From five-minute ECG signals, the processing module algorithms perform a spectral estimation of the HRV. The experimental results demonstrate the viability of the smart device and the proposed processing algorithms.Fundación Pública Andaluza Progreso y Salud. Gobierno de Andalucía PI-0010-2013 y PI-0041-2014Ministerio de Economía y Competitividad (Instituto de Salud Carlos III) PI15 / 00306 y DTS15 / 00195CIBER-BBN INT-2-CAR

    Artifact Rejection Methodology Enables Continuous, Noninvasive Measurement of Gastric Myoelectric Activity in Ambulatory Subjects.

    Get PDF
    The increasing prevalence of functional and motility gastrointestinal (GI) disorders is at odds with bottlenecks in their diagnosis, treatment, and follow-up. Lack of noninvasive approaches means that only specialized centers can perform objective assessment procedures. Abnormal GI muscular activity, which is coordinated by electrical slow-waves, may play a key role in symptoms. As such, the electrogastrogram (EGG), a noninvasive means to continuously monitor gastric electrical activity, can be used to inform diagnoses over broader populations. However, it is seldom used due to technical issues: inconsistent results from single-channel measurements and signal artifacts that make interpretation difficult and limit prolonged monitoring. Here, we overcome these limitations with a wearable multi-channel system and artifact removal signal processing methods. Our approach yields an increase of 0.56 in the mean correlation coefficient between EGG and the clinical "gold standard", gastric manometry, across 11 subjects (p < 0.001). We also demonstrate this system's usage for ambulatory monitoring, which reveals myoelectric dynamics in response to meals akin to gastric emptying patterns and circadian-related oscillations. Our approach is noninvasive, easy to administer, and has promise to widen the scope of populations with GI disorders for which clinicians can screen patients, diagnose disorders, and refine treatments objectively

    Textile based electrodes for ECG and EMG measurements

    Get PDF
    Biopotential signals are an important tool for monitoring our health and thanks to the evolution of technology, they are being increasingly used in several areas. There are however some problems with conventional electrodes such as irritation that need to be surpassed and textile electrodes may represent a good alternative. This paper proposes a design approach for textile based electrodes developed by our research group, in which the construction of the electrodes is based on 3D surface design of weft knitted structures, which increases thickness and allows to improve the permanent contact between electrode and skin, thus contributing for the solution of one of the problems identified by the research community.This work is financed by FEDER funds through the Competitivity Factors Operational Programme - COMPETE and by national funds through FCT – Foundation for Science and Technology within the scope of the project POCI-01-0145-FEDER-007136.info:eu-repo/semantics/acceptedVersio

    Long-Term Clinical Evaluation of Novel ECG Electrodes

    Get PDF
    The standard silver / silver-chloride (Ag/AgCl) electrode is moisture-sensitive and susceptible to motion artifacts that reduce electrocardiogram (ECG) signal quality. FLEXcon USA© has developed a moisture-independent and less-expensive electrode design that can improve short- and long-term clinical ECG measurement. Ten subjects were recruited for each of two clinical studies designed to quantify biocompatibility for 7 days and ECG quality for 4 days. The Gen. 2-A and Ag/AgCl adhesives lost 7.14% and 50% adhesion, respectively. The correlation coefficients between heart rates measured by the FLEXcon and Ag/AgCl electrodes were both 0.997. The FLEXcon adhesive and the industry standard Ag/AgCl produced statistically similar ECG signals in short- and long-term clinical applications

    Non-invasive Electronic Biosensor Circuits and Systems

    Get PDF
    An aging population has lead to increased demand for health-care and an interest in moving health care services from the hospital to the home to reduce the burden on society. One enabling technology is comfortable monitoring and sensing of bio-signals. Sensors can be embedded in objects that people interact with daily such as a computer, chair, bed, toilet, car, telephone or any portable personal electronic device. Moreover, the relatively recent and wide availability of microelectronics that provide the capabilities of embedded software, open access wireless protocols and long battery life has led many research groups to develop wearable, wireless bio-sensor systems that are worn on the body and integrated into clothing. These systems are capable of interaction with other devices that are nowadays commonly in our possession such as a mobile phone, laptop, PDA or smart multifunctional MP3 player. The development of systems for wireless bio-medical long term monitoring is leading to personal monitoring, not just for medical reasons, but also for enhancing personal awareness and monitoring self-performance, as with sports-monitoring for athletes. These developments also provide a foundation for the Brain Computer Interface (BCI) that aims to directly monitor brain signals in order to control or manipulate external objects. This provides a new communication channel to the brain that does not require activation of muscles and nerves. This innovative and exciting research field is in need of reliable and easy to use long term recording systems (EEG). In particular we highlight the development and broad applications of our own circuits for wearable bio-potential sensor systems enabled by the use of an amplifier circuit with sufficiently high impedance to allow the use of passive dry electrodes which overcome the significant barrier of gel based contacts

    Design of a wearable sensor system for neonatal seizure monitoring

    Get PDF
    • …
    corecore