1,027 research outputs found

    Hemodynamic study in a real intracranial aneurysm: an in vitro and in silico approach

    Get PDF
    Mestrado de dupla diplomação com o Centro Federal de Educação Tecnológica Celso Suckow da Fonseca - Cefet/RJIntracranial aneurysm (IA) is a cerebrovascular disease with high rates of mortality and morbidity when it ruptures. It is known that changes in the intra-aneurysmal hemodynamic load play a significant factor in the development and rupture of IA. However, these factors are not fully understood. In this sense, the main objective of this work is to study the hemodynamic behavior during the blood analogues flow inside an AI and to determine its influence on the evolution of this pathology. To this end, experimental and numerical studies were carried out, using a real AI model obtained using computerized angiography. In the experimental approach, it was necessary, in the initial phase, to develop and manufacture biomodels from medical images of real aneurysms. Two techniques were used to manufacture the biomodels: rapid prototyping and gravity casting. The materials used to obtain the biomodels were of low cost. After manufacture, the biomodels were compared to each other for their transparency and final structure and proved to be suitable for testing flow visualizations. Numerical studies were performed with the aid of the Ansys Fluent software, using computational fluid dynamics (CFD), using the finite volume method. Subsequently, flow tests were performed experimentally and numerically using flow rates calculated from the velocity curve of a patient's doppler test. The experimental and numerical tests, in steady-state, made it possible to visualize the three-dimensional behavior of the flow inside the aneurysm, identifying the vortex zones created throughout the cardiac cycle. Correlating the results obtained in the two analyzes, it was possible to identify that the areas of vortexes are characterized by low speed and with increasing the fluid flow, the vortexes are positioned closer to the wall. These characteristics are associated with the rupture of an intracranial aneurysm. There was also a good qualitative correlation between numerical and experimental results.O aneurisma intracraniano (AI) é uma patologia cerebrovascular com altas taxas de mortalidade e morbidade quando se rompe. Sabe-se que alterações na carga hemodinâmica intra-aneurismática exerce um fator significativo no desenvolvimento e ruptura de AI, porém, esses fatores não estão totalmente compreendidos. Nesse sentido, o objetivo principal deste trabalho é o de estudar o comportamento hemodinâmico durante o escoamento de fluidos análogos do sangue no interior de um AI e determinar a sua influência na evolução da patologia. Para tal, foram realizados estudos experimentais e numéricos, utilizando um modelo de AI real obtido por meio de uma angiografia computadorizada. Na abordagem experimental foi necessário, na fase inicial, desenvolver e fabricar biomodelos a partir de imagens médicas de um aneurisma real. No fabrico dos biomodelos foram utilizadas duas técnicas: a prototipagem rápida e o vazamento por gravidade. Os materiais utilizados para a obtenção dos biomodelos foram de baixo custo. Após a fabricação, os biomodelos foram comparados entre si quanto à sua transparência e estrutura final e verificou-se serem adequados para testes de visualizações do fluxo. Os estudos numéricos foram realizados com recurso ao software Ansys Fluent, utilizando a dinâmica dos fluidos computacional (CFD), através do método dos volumes finitos. Posteriormente, foram realizados testes de escoamento experimentais e numéricos, utilizando caudais determinados a partir da curva de velocidades do ensaio doppler de um paciente. Os testes experimentais e numéricos, em regime permanente, possibilitaram a visualização do comportamento tridimensional do fluxo no interior do aneurisma, identificando as zonas de vórtices criadas ao longo do ciclo cardíaco. Correlacionando os resultados obtidos nas duas análises, foi possível identificar que as áreas de vórtices são caracterizadas por uma baixa velocidade e com o aumento do caudal os vórtices posicionam-se mais próximos da parede. Essas características apresentadas estão associadas com a ruptura de aneurisma intracraniano. Verificou-se, também, uma boa correlação qualitativa entre os resultados numéricos e experimentais

    Near-wall hemodynamic parameters quantification in in vitro intracranial aneurysms with 7 T PC-MRI.

    Get PDF
    OBJECTIVE Wall shear stress (WSS) and its derived spatiotemporal parameters have proven to play a major role on intracranial aneurysms (IAs) growth and rupture. This study aims to demonstrate how ultra-high field (UHF) 7 T phase contrast magnetic resonance imaging (PC-MRI) coupled with advanced image acceleration techniques allows a highly resolved visualization of near-wall hemodynamic parameters patterns in in vitro IAs, paving the way for more robust risk assessment of their growth and rupture. MATERIALS AND METHODS We performed pulsatile flow measurements inside three in vitro models of patient-specific IAs using 7 T PC-MRI. To this end, we built an MRI-compatible test bench, which faithfully reproduced a typical physiological intracranial flow rate in the models. RESULTS The ultra-high field 7 T images revealed WSS patterns with high spatiotemporal resolution. Interestingly, the high oscillatory shear index values were found in the core of low WSS vortical structures and in flow stream intersecting regions. In contrast, maxima of WSS occurred around the impinging jet sites. CONCLUSIONS We showed that the elevated signal-to-noise ratio arising from 7 T PC-MRI enabled to resolve high and low WSS patterns with a high degree of detail

    Comparison of existing aneurysm models and their path forward

    Full text link
    The two most important aneurysm types are cerebral aneurysms (CA) and abdominal aortic aneurysms (AAA), accounting together for over 80\% of all fatal aneurysm incidences. To minimise aneurysm related deaths, clinicians require various tools to accurately estimate its rupture risk. For both aneurysm types, the current state-of-the-art tools to evaluate rupture risk are identified and evaluated in terms of clinical applicability. We perform a comprehensive literature review, using the Web of Science database. Identified records (3127) are clustered by modelling approach and aneurysm location in a meta-analysis to quantify scientific relevance and to extract modelling patterns and further assessed according to PRISMA guidelines (179 full text screens). Beside general differences and similarities of CA and AAA, we identify and systematically evaluate four major modelling approaches on aneurysm rupture risk: finite element analysis and computational fluid dynamics as deterministic approaches and machine learning and assessment-tools and dimensionless parameters as stochastic approaches. The latter score highest in the evaluation for their potential as clinical applications for rupture prediction, due to readiness level and user friendliness. Deterministic approaches are less likely to be applied in a clinical environment because of their high model complexity. Because deterministic approaches consider underlying mechanism for aneurysm rupture, they have improved capability to account for unusual patient-specific characteristics, compared to stochastic approaches. We show that an increased interdisciplinary exchange between specialists can boost comprehension of this disease to design tools for a clinical environment. By combining deterministic and stochastic models, advantages of both approaches can improve accessibility for clinicians and prediction quality for rupture risk.Comment: 46 pages, 5 figure

    Multiscale Modeling of Cardiovascular Flows

    Get PDF
    Simulations of blood flow in the cardiovascular system offer investigative and predictive capabilities to augment current clinical tools. Using image-based modeling, the Navier-Stokes equations can be solved to obtain detailed 3-dimensional hemodynamics in patient-specific anatomical models. Relevant parameters such as wall shear stress and particle residence times can then be calculated from the 3D results and correlated with clinical data for treatment planning and device evaluation. Reduced-order models such as open or closed loop 0D lumped-parameter models can simulate the dynamic behavior of the circulatory system using an analogy to electrical circuits. When coupled to 3D simulations as boundary conditions, they produce physiologically realistic pressure and flow conditions in the 3D domain. We describe fundamentals and current state of the art of patient-specific, multi-scale computational modeling approaches applied to cardiovascular disease. These tools enable investigations of hemodynamics reflecting individual patients physiology, and we provide several illustrative case studies. These methods can supplement current clinical measurement and imaging capabilities and provide predictions of patient outcomes for surgical planning and risk stratification

    Proposal for Numerical Benchmarking of Fluid-Structure Interaction in Cerebral Aneurysms

    Full text link
    Computational fluid dynamics is intensively used to deepen the understanding of aneurysm growth and rupture in the attempt to support physicians during therapy planning. Numerous studies have assumed fully-rigid vessel walls in their simulations, whose sole hemodynamics may fail to provide a satisfactory criterion for rupture risk assessment. Moreover, direct in-vivo observations of intracranial aneurysm pulsation have been recently reported, encouraging the development of fluid-structure interaction for their modelling and for new assessments. In this work, we describe a new fluid-structure interaction benchmark setting for the careful evaluation of different aneurysm shapes. The studied configurations consist of three real aneurysm domes positioned on a toroidal channel. All geometric features, meshing characteristics, flow quantities, comparisons with a rigid-wall model and corresponding plots are provided. Reported results emphasize the alteration of flow patterns and hemodynamic descriptors when moving from the rigid-wall model to the complete fluid-structure interaction framework, thereby underlining the importance of the coupling between hemodynamics and the surrounding vessel tissue.Comment: 23 pages, 14 figure

    Computer simulations in stroke prevention : design tools and strategies towards virtual procedure planning

    Get PDF

    Improving Cardiovascular Stent Design Using Patient-Specific Models and Shape Optimization

    Get PDF
    Stent geometry influences local hemodynamic alterations (i.e. the forces moving blood through the cardiovascular system) associated with adverse clinical outcomes. Computational fluid dynamics (CFD) is frequently used to quantify stent-induced hemodynamic disturbances, but previous CFD studies have relied on simplified device or vascular representations. Additionally, efforts to minimize stent-induced hemodynamic disturbances using CFD models often only compare a small number of possible stent geometries. This thesis describes methods for modeling commercial stents in patient-specific vessels along with computational techniques for determining optimal stent geometries that address the limitations of previous studies. An efficient and robust method was developed for virtually implanting stent models into patient-specific vascular geometries derived from medical imaging data. Models of commercial stent designs were parameterized to allow easy control over design features. Stent models were then virtually implanted into vessel geometries using a series of Boolean operations. This approach allowed stented vessel models to be automatically regenerated for rapid analysis of the contribution of design features to resulting hemodynamic alterations. The applicability of the method was demonstrated with patient-specific models of a stented coronary artery bifurcation and basilar trunk aneurysm to reveal how it can be used to investigate differences in hemodynamic performance in complex vascular beds for a variety of clinical scenarios. To identify hemodynamically optimal stents designs, a computational framework was constructed to couple CFD with a derivative-free optimization algorithm. The optimization algorithm was fully-automated such that solid model construction, mesh generation, CFD simulation and time-averaged wall shear stress (TAWSS) quantification did not require user intervention. The method was applied to determine the optimal number of circumferentially repeating stent cells (NC) for a slotted-tube stents and various commercial stents. Optimal stent designs were defined as those minimizing the area of low TAWSS. It was determined the optimal value of NC is dependent on the intrastrut angle with respect to the primary flow direction. Additionally, the geometries of current commercial stents were found to generally incorporate a greater NC than is hemodynamically optimal. The application of the virtual stent implantation and optimization methods may lead to stents with superior hemodynamic performance and the potential for improved clinical outcomes. Future in vivo studies are needed to validate the findings of the computational results obtained from the methods developed in this thesis
    corecore