7,718 research outputs found
Micro Fourier Transform Profilometry (FTP): 3D shape measurement at 10,000 frames per second
Recent advances in imaging sensors and digital light projection technology
have facilitated a rapid progress in 3D optical sensing, enabling 3D surfaces
of complex-shaped objects to be captured with improved resolution and accuracy.
However, due to the large number of projection patterns required for phase
recovery and disambiguation, the maximum fame rates of current 3D shape
measurement techniques are still limited to the range of hundreds of frames per
second (fps). Here, we demonstrate a new 3D dynamic imaging technique, Micro
Fourier Transform Profilometry (FTP), which can capture 3D surfaces of
transient events at up to 10,000 fps based on our newly developed high-speed
fringe projection system. Compared with existing techniques, FTP has the
prominent advantage of recovering an accurate, unambiguous, and dense 3D point
cloud with only two projected patterns. Furthermore, the phase information is
encoded within a single high-frequency fringe image, thereby allowing
motion-artifact-free reconstruction of transient events with temporal
resolution of 50 microseconds. To show FTP's broad utility, we use it to
reconstruct 3D videos of 4 transient scenes: vibrating cantilevers, rotating
fan blades, bullet fired from a toy gun, and balloon's explosion triggered by a
flying dart, which were previously difficult or even unable to be captured with
conventional approaches.Comment: This manuscript was originally submitted on 30th January 1
Low dose and fast grating-based x-ray phase-contrast imaging using the integrating-bucket phase modulation technique
X-ray phase-contrast imaging has experienced rapid development over the last
few decades, and in this technology, the phase modulation strategy of
phase-stepping is used most widely to measure the sample's phase signal.
However, because of its discontinuous nature, phase-stepping has the defects of
worse mechanical stability and high exposure dose, which greatly hinder its
wide application in dynamic phase measurement and potential clinical
applications. In this manuscript, we demonstrate preliminary research on the
use of integrating-bucket phase modulation method to retrieve the phase
information in grating-based X-ray phase-contrast imaging. Experimental results
showed that our proposed method can be well employed to extract the
differential phase-contrast image, compared with the current mostly used
phase-stepping strategy, advantage of integrating-bucket phase modulation
technique is that fast measurement and low dose are promising.Comment: 14 pages, 6 figure
Kinect Range Sensing: Structured-Light versus Time-of-Flight Kinect
Recently, the new Kinect One has been issued by Microsoft, providing the next
generation of real-time range sensing devices based on the Time-of-Flight (ToF)
principle. As the first Kinect version was using a structured light approach,
one would expect various differences in the characteristics of the range data
delivered by both devices. This paper presents a detailed and in-depth
comparison between both devices. In order to conduct the comparison, we propose
a framework of seven different experimental setups, which is a generic basis
for evaluating range cameras such as Kinect. The experiments have been designed
with the goal to capture individual effects of the Kinect devices as isolatedly
as possible and in a way, that they can also be adopted, in order to apply them
to any other range sensing device. The overall goal of this paper is to provide
a solid insight into the pros and cons of either device. Thus, scientists that
are interested in using Kinect range sensing cameras in their specific
application scenario can directly assess the expected, specific benefits and
potential problem of either device.Comment: 58 pages, 23 figures. Accepted for publication in Computer Vision and
Image Understanding (CVIU
Handheld 3D scanning system for in-vivo imaging of skin cancer
Postprint (published version
Real-time tissue viability assessment using near-infrared light
Despite significant advances in medical imaging technologies, there currently exist no tools to effectively assist healthcare professionals during surgical procedures. In turn, procedures remain subjective and dependent on experience, resulting in avoidable failure and significant quality of care disparities across hospitals.
Optical techniques are gaining popularity in clinical research because they are low cost, non-invasive, portable, and can retrieve both fluorescence and endogenous contrast information, providing physiological information relative to perfusion, oxygenation, metabolism, hydration, and sub-cellular content. Near-infrared (NIR) light is especially well suited for biological tissue and does not cause tissue damage from ionizing radiation or heat.
My dissertation has been focused on developing rapid imaging techniques for mapping endogenous tissue constituents to aid surgical guidance. These techniques allow, for the first time, video-rate quantitative acquisition over a large field of view (> 100 cm2) in widefield and endoscopic implementations. The optical system analysis has been focused on the spatial-frequency domain for its ease of quantitative measurements over large fields of view and for its recent development in real-time acquisition, single snapshot of optical properties (SSOP) imaging.
Using these methods, this dissertation provides novel improvements and implementations to SSOP, including both widefield and endoscopic instrumentations capable of video-rate acquisition of optical properties and sample surface profile maps. In turn, these measures generate profile-corrected maps of hemoglobin concentration that are highly beneficial for perfusion and overall tissue viability. Also utilizing optical property maps, a novel technique for quantitative fluorescence imaging was also demonstrated, showing large improvement over standard and ratiometric methods. To enable real-time feedback, rapid processing algorithms were designed using lookup tables that provide a 100x improvement in processing speed. Finally, these techniques were demonstrated in vivo to investigate their ability for early detection of tissue failure due to ischemia. Both pre-clinical studies show endogenous contrast imaging can provide early measures of future tissue viability.
The goal of this work has been to provide the foundation for real-time imaging systems that provide tissue constituent quantification for tissue viability assessments.2018-01-09T00:00:00
- …