107 research outputs found
Nonparametric Online Learning Control for Soft Continuum Robot: An Enabling Technique for Effective Endoscopic Navigation.
Bioinspired robotic structures comprising soft actuation units have attracted increasing research interest. Taking advantage of its inherent compliance, soft robots can assure safe interaction with external environments, provided that precise and effective manipulation could be achieved. Endoscopy is a typical application. However, previous model-based control approaches often require simplified geometric assumptions on the soft manipulator, but which could be very inaccurate in the presence of unmodeled external interaction forces. In this study, we propose a generic control framework based on nonparametric and online, as well as local, training to learn the inverse model directly, without prior knowledge of the robot's structural parameters. Detailed experimental evaluation was conducted on a soft robot prototype with control redundancy, performing trajectory tracking in dynamically constrained environments. Advanced element formulation of finite element analysis is employed to initialize the control policy, hence eliminating the need for random exploration in the robot's workspace. The proposed control framework enabled a soft fluid-driven continuum robot to follow a 3D trajectory precisely, even under dynamic external disturbance. Such enhanced control accuracy and adaptability would facilitate effective endoscopic navigation in complex and changing environments
Soft Robot-Assisted Minimally Invasive Surgery and Interventions: Advances and Outlook
Since the emergence of soft robotics around two decades ago, research interest in the field has escalated at a pace. It is fuelled by the industry's appreciation of the wide range of soft materials available that can be used to create highly dexterous robots with adaptability characteristics far beyond that which can be achieved with rigid component devices. The ability, inherent in soft robots, to compliantly adapt to the environment, has significantly sparked interest from the surgical robotics community. This article provides an in-depth overview of recent progress and outlines the remaining challenges in the development of soft robotics for minimally invasive surgery
A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation
The application of laser technologies in surgical interventions has been accepted in the clinical
domain due to their atraumatic properties. In addition to manual application of fibre-guided
lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours
has been prevailed in ENT surgery. However, TLM requires many years of surgical training
for tumour resection in order to preserve the function of adjacent organs and thus preserve the
patient’s quality of life. The positioning of the microscopic laser applicator outside the patient
can also impede a direct line-of-sight to the target area due to anatomical variability and limit
the working space. Further clinical challenges include positioning the laser focus on the tissue
surface, imaging, planning and performing laser ablation, and motion of the target area during
surgery. This dissertation aims to address the limitations of TLM through robotic approaches and
intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no
highly integrated platform for endoscopic delivery of focused laser radiation is available to date.
Likewise, there are no known devices that incorporate scene information from endoscopic imaging
into ablation planning and execution. For focusing of the laser beam close to the target tissue, this
work first presents miniaturised focusing optics that can be integrated into endoscopic systems.
Experimental trials characterise the optical properties and the ablation performance. A robotic
platform is realised for manipulation of the focusing optics. This is based on a variable-length
continuum manipulator. The latter enables movements of the endoscopic end effector in five
degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the
robot are integrated into a modular framework that is evaluated experimentally. The manipulation
of focused laser radiation also requires precise adjustment of the focal position on the tissue. For
this purpose, visual, haptic and visual-haptic assistance functions are presented. These support
the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic
assistance are demonstrated in a user study. The system performance and usability of the overall
robotic system are assessed in an additional user study. Analogous to a clinical scenario, the
subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the
spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser
ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact
laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergefĂĽhrten
Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von
Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion
jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu
sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet
durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische
Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die
Bildgebung, die Planung und AusfĂĽhrung der Laserablation sowie intraoperative Bewegungen
des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch
robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal
invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen fĂĽr die endoskopische
Applikation fokussierter Laserstrahlung verfĂĽgbar. Ebenfalls sind keine Systeme bekannt, die
Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausfĂĽhrung
einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst
eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur
Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem
längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer
mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fĂĽnf Freiheitsgraden.
Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework
eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine
präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation
zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der
visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit
des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu
einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die
mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation
werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen
einen positiven Effekt der Automationskonzepte fĂĽr die kontaktfreie Laserchirurgie
A Hybrid Adaptive Controller for Soft Robot Interchangeability
Soft robots have been leveraged in considerable areas like surgery,
rehabilitation, and bionics due to their softness, flexibility, and safety.
However, it is challenging to produce two same soft robots even with the same
mold and manufacturing process owing to the complexity of soft materials.
Meanwhile, widespread usage of a system requires the ability to fabricate
replaceable components, which is interchangeability. Due to the necessity of
this property, a hybrid adaptive controller is introduced to achieve
interchangeability from the perspective of control approaches. This method
utilizes an offline trained recurrent neural network controller to cope with
the nonlinear and delayed response from soft robots. Furthermore, an online
optimizing kinematics controller is applied to decrease the error caused by the
above neural network controller. Soft pneumatic robots with different
deformation properties but the same mold have been included for validation
experiments. In the experiments, the systems with different actuation
configurations and the different robots follow the desired trajectory with
errors of 0.040 and 0.030 compared with the working space length, respectively.
Such an adaptive controller also shows good performance on different control
frequencies and desired velocities. This controller endows soft robots with the
potential for wide application, and future work may include different offline
and online controllers. A weight parameter adjusting strategy may also be
proposed in the future.Comment: 8 pages, 9 figures, 4 table
TMTDyn: A Matlab package for modeling and control of hybrid rigid–continuum robots based on discretized lumped systems and reduced-order models
A reliable, accurate, and yet simple dynamic model is important to analyzing, designing, and controlling hybrid rigid–continuum robots. Such models should be fast, as simple as possible, and user-friendly to be widely accepted by the evergrowing robotics research community. In this study, we introduce two new modeling methods for continuum manipulators: a general reduced-order model (ROM) and a discretized model with absolute states and Euler–Bernoulli beam segments (EBA). In addition, a new formulation is presented for a recently introduced discretized model based on Euler–Bernoulli beam segments and relative states (EBR). We implement these models in a Matlab software package, named TMTDyn, to develop a modeling tool for hybrid rigid–continuum systems. The package features a new high-level language (HLL)
text-based interface, a CAD-file import module, automatic formation of the system equation of motion (EOM) for different modeling and control tasks, implementing Matlab C-mex functionality for improved performance, and modules for static and linear modal analysis of a hybrid system. The underlying theory and software package are validated for modeling experimental results for (i) dynamics of a continuum appendage, and (ii) general deformation of a fabric sleeve worn by a rigid link pendulum. A comparison shows higher simulation accuracy (8–14% normalized error) and numerical robustness of the ROM model for a system with a small number of states, and computational efficiency of the EBA model with
near real-time performances that makes it suitable for large systems. The challenges and necessary modules to further automate the design and analysis of hybrid systems with a large number of states are briefly discussed
TMTDyn: A Matlab package for modeling and control of hybrid rigid-continuum robots based on discretized lumped systems and reduced-order models
A reliable, accurate, and yet simple dynamic model is important to analyzing, designing, and controlling hybrid rigid–continuum robots. Such models should be fast, as simple as possible, and user-friendly to be widely accepted by the ever-growing robotics research community. In this study, we introduce two new modeling methods for continuum manipulators: a general reduced-order model (ROM) and a discretized model with absolute states and Euler–Bernoulli beam segments (EBA). In addition, a new formulation is presented for a recently introduced discretized model based on Euler–Bernoulli beam segments and relative states (EBR). We implement these models in a Matlab software package, named TMTDyn, to develop a modeling tool for hybrid rigid–continuum systems. The package features a new high-level language (HLL) text-based interface, a CAD-file import module, automatic formation of the system equation of motion (EOM) for different modeling and control tasks, implementing Matlab C-mex functionality for improved performance, and modules for static and linear modal analysis of a hybrid system. The underlying theory and software package are validated for modeling experimental results for (i) dynamics of a continuum appendage, and (ii) general deformation of a fabric sleeve worn by a rigid link pendulum. A comparison shows higher simulation accuracy (8–14% normalized error) and numerical robustness of the ROM model for a system with a small number of states, and computational efficiency of the EBA model with near real-time performances that makes it suitable for large systems. The challenges and necessary modules to further automate the design and analysis of hybrid systems with a large number of states are briefly discussed
SOFT ROBOTIC APPENDAGES USING PNEUMATIC ARTIFICIAL MUSCLES
This dissertation focuses on advancing the state of the art in soft robotics using pneumatic artificial (PAM) actuators. Pneumatic artificial muscles are currently used in robotic and prosthetic applications due to their high power to weight ratio, controllable compliance, and simple design. Contractile PAMs are typically used in traditional hard robotics in place of heavy electric motors. As the field of soft robotics grows, extensile PAMs are beginning to have increased usage. The bladder of a PAM affects common actuator performance metrics, specifically: blocked force, free contraction, hysteresis, and dead-band pressure. This work investigates the effect that bladder thickness has on static actuation performance of small scale PAMs. Miniature PAMs were fabricated with a range of bladder thicknesses then experimentally characterized in quasi-static conditions, where results showed that increasing bladder wall thickness decreases blocked force and free contraction, while the dead-band pressure increases. A nonlinear model was then applied to determine the structure of the stress-strain relationship that enables accurate modeling and the minimum number of terms. Contractile and extensile PAMs were experimentally fabricated and parametrically compared to demonstrate the advantages and disadvantages of each type of PAM and applications for which they are best suited. An additional PAM model was developed based on finite strain theory to address the lack of predicitive models. The closed-form pneumatic artificial muscle quasi-static actuator force is obtained. The analysis was experimentally validated using actuation force versus contraction ratio test data at a series of discrete inflation pressures for four different pneumatic artificial muscles, two contractile and two extensile. This work investigates adding bio-inspired ossicle structures from brittle stars to pneumatic artificial muscle continuum arm sections. The ossicle structure increases the range of motion and load capability of the continuum arm section while reducing the pneumatic pressure requirements. In this work, a static model of the continuum arm section is developed assuming constant curvature in the section and finding the center of mass of the section and its end plate. This model is validated by comparing the pressure-angle relationship at various loading conditions
- …