Testing of Asynchronous NULL Conventional Logic (NCL) Circuits
Due to the absence of a global clock and presence of more state holding elements that synchronize the control and data paths, conventional automatic test pattern generation (ATPG) algorithms would fail when applied to asynchronous circuits, leading to poor fault coverage. This paper focuses on design for test (DFT) techniques aimed at making asynchronous NCL designs testable using existing DFT CAD tools with reasonable gate overhead, by enhancing controllability of feedback nets and observability for fault sites that are flagged unobservable. The proposed approach performs scan and test points insertion on NCL designs using custom ATPG library. The approach has been automated, which is essential for large systems; and are fully compatible with industry standard tools
High quality testing of grid style power gating
This paper shows that existing delay-based testing techniques for power gating exhibit fault coverage loss due to unconsidered delays introduced by the structure of the virtual voltage power-distribution-network (VPDN). To restore this loss, which could reach up to 70.3% on stuck-open faults, we propose a design-for-testability (DFT) logic that considers the impact of VPDN on fault coverage in order to constitute the proper interface between the VPDN and the DFT. The proposed logic can be easily implemented on-top of existing DFT solutions and its overhead is optimized by an algorithm that offers trade-off flexibility between test-application-time and hardware overhead. Through physical layout SPICE simulations, we show complete fault coverage recovery on stuck-open faults and 43.2% test-application-time improvement compared to a previously proposed DFT technique. To the best of our knowledge, this paper presents the first analysis of the VPDN impact on test qualit
Digital Signal Generator And Automatic Test Equipment Having The Same
A digital signal generator includes an input unit configured to receive signal information of a target data signal, a controller configured to calculate at least two delay values and at least two data values, the at least two delay values and the at least two data values being used to generate a data signal corresponding to the signal information input through the input unit, a multi-phase clock generator configured to delay a reference clock signal based on the at least two delay values to generate at least two clock signals having different phases, a signal generator configured to generate at least two data signals by assigning the at least two data values to the at least two clock signals, and a logic gate unit configured to generate the data signal corresponding to the signal information input through the input unit based on the at least two data signals.Samsung Electronics Co., Ltd.Georgia Tech Research Corporatio
A Technique of Direct Tension Measurement of a Strung Fine Wire
We present a new technique of direct measurement of wire tensions in wire
chambers. A specially designed circuit plucks the wire using the Lorentz force
and measures the frequency of damped transverse oscillations of the wire. The
technique avoids the usual time-consuming necessity of tuning circuit parameter
to a resonance. It allows a fast and convenient determination of tensions and
is straightforward to implement.Comment: 15 pages with 9 figure
An absolute calibration system for millimeter-accuracy APOLLO measurements
Lunar laser ranging provides a number of leading experimental tests of
gravitation -- important in our quest to unify General Relativity and the
Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging
Operation (APOLLO) has for years achieved median range precision at the ~2 mm
level. Yet residuals in model-measurement comparisons are an order-of-magnitude
larger, raising the question of whether the ranging data are not nearly as
accurate as they are precise, or if the models are incomplete or
ill-conditioned. This paper describes a new absolute calibration system (ACS)
intended both as a tool for exposing and eliminating sources of systematic
error, and also as a means to directly calibrate ranging data in-situ. The
system consists of a high-repetition-rate (80 MHz) laser emitting short (< 10
ps) pulses that are locked to a cesium clock. In essence, the ACS delivers
photons to the APOLLO detector at exquisitely well-defined time intervals as a
"truth" input against which APOLLO's timing performance may be judged and
corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond
the ~3 mm level, suggesting that historical APOLLO data are of high quality and
motivating continued work on model capabilities. The ACS provides the means to
deliver APOLLO data both accurate and precise below the 2 mm level.Comment: 21 pages, 10 figures, submitted to Classical and Quantum Gravit
- …