616 research outputs found

    Focal Spot, Summer/Fall 2009

    Get PDF
    https://digitalcommons.wustl.edu/focal_spot_archives/1112/thumbnail.jp

    History of mammography: analysis of breast imaging diagnostic achievements over the last century

    Get PDF
    Breast cancer is the most common forms of cancer and a leading cause of mortality in women. Early and correct diagnosis is, therefore, essential to save lives. The development of diagnostic imaging applied to the breast has been impressive in recent years and the most used diagnostic test in the world is mammography, a low-dose X-ray technique used for imaging the breast. In the first half of the 20th century, the diagnosis was in practice only clinical, with consequent diagnostic delay and an unfavorable prognosis in the short term. The rise of organized mammography screening has led to a remarkable reduction in mortality through the early detection of breast malignancies. This historical review aims to offer a complete panorama of the development of mammography and breast imaging during the last century. Through this study, we want to understand the foundations of the pillar of radiology applied to the breast through to the most modern applications such as contrast-enhanced mammography (CEM), artificial intelligence, and radiomics. Understanding the history of the development of diagnostic imaging applied to the breast can help us understand how to better direct our efforts toward an increasingly personalized and effective diagnostic approach. The ultimate goal of imaging applied to the detection of breast malignancies should be to reduce mortality from this type of disease as much as possible. With this paper, we want to provide detailed documentation of the main steps in the evolution of breast imaging for the diagnosis of breast neoplasms; we also want to open up new scenarios where the possible current and future applications of imaging are aimed at being more precise and personalized

    Modern Breast Cancer Detection: A Technological Review

    Get PDF
    Breast cancer is a serious threat worldwide and is the number two killer of women in the United States. The key to successful management is screening and early detection. What follows is a description of the state of the art in screening and detection for breast cancer as well as a discussion of new and emerging technologies. This paper aims to serve as a starting point for those who are not acquainted with this growing field

    Digital Breast Tomosynthesis: Outcomes and Tumor Characteristics in Women Recalled From Screening

    Get PDF
    Breast cancer is the most frequently diagnosed and second leading cause of cancer deaths in women, accounting for 25% of cancer diagnoses and 15.4% of cancer deaths in developed countries. Thus, early detection of breast cancer through screening has become increasingly important in mortality reduction efforts. Yet, mammography has faced considerable controversy in balancing the benefits and harms associated with screening. Digital breast tomosynthesis has emerged as an important imaging technique which, compared to standard mammography alone, reduces recall rates and false positives, and improves cancer detection. Additional cancers detected with tomosynthesis have been poorly characterized in the literature to date. To assess the effectiveness of screening with adjunct tomosynthesis, we propose to utilize our large database to characterize cancers detected in true positive recalls. Our findings will help clinicians make well-informed decisions for further management of women with mammographically suspicious or inconclusive findings, and contribute to future screening guidelines

    Bone health assessment via digital wrist tomosynthesis in the mammography setting

    Get PDF
    Bone fractures attributable to osteoporosis are a significant problem. Though preventative treatment options are available for individuals who are at risk of a fracture, a substantial number of these individuals are not identified due to lack of adherence to bone screening recommendations. The issue is further complicated as standard diagnosis of osteoporosis is based on bone mineral density (BMD) derived from dual energy x-ray absorptiometry (DXA), which, while helpful in identifying many at risk, is limited in fully predicting risk of fracture. It is reasonable to expect that bone screening would become more prevalent and efficacious if offered in coordination with digital breast tomosynthesis (DBT) exams, provided that osteoporosis can be assessed using a DBT modality. Therefore, the objective of the current study was to explore the feasibility of using digital tomosynthesis imaging in a mammography setting. To this end, we measured density, cortical thickness and microstructural properties of the wrist bone, correlated these to reference measurements from microcomputed tomography and DXA, demonstrated the application in vivo in a small group of participants, and determined the repeatability of the measurements. We found that measurements from digital wrist tomosynthesis (DWT) imaging with a DBT scanner were highly repeatable ex vivo (error = 0.05%-9.62%) and in vivo (error = 0.06%-10.2%). In ex vivo trials, DWT derived BMDs were strongly correlated with reference measurements (R = 0.841-0.980), as were cortical thickness measured at lateral and medial cortices (R = 0.991 and R = 0.959, respectively) and the majority of microstructural measures (R = 0.736-0.991). The measurements were quick and tolerated by human patients with no discomfort, and appeared to be different between young and old participants in a preliminary comparison. In conclusion, DWT is feasible in a mammography setting, and informative on bone mass, cortical thickness, and microstructural qualities that are known to deteriorate in osteoporosis. To our knowledge, this study represents the first application of DBT for imaging bone. Future clinical studies are needed to further establish the efficacy for diagnosing osteoporosis and predicting risk of fragility fracture using DWT

    Deep learning reconstruction of digital breast tomosynthesis images for accurate breast density and patient-specific radiation dose estimation

    Full text link
    The two-dimensional nature of mammography makes estimation of the overall breast density challenging, and estimation of the true patient-specific radiation dose impossible. Digital breast tomosynthesis (DBT), a pseudo-3D technique, is now commonly used in breast cancer screening and diagnostics. Still, the severely limited 3rd dimension information in DBT has not been used, until now, to estimate the true breast density or the patient-specific dose. This study proposes a reconstruction algorithm for DBT based on deep learning specifically optimized for these tasks. The algorithm, which we name DBToR, is based on unrolling a proximal-dual optimization method. The proximal operators are replaced with convolutional neural networks and prior knowledge is included in the model. This extends previous work on a deep learning-based reconstruction model by providing both the primal and the dual blocks with breast thickness information, which is available in DBT. Training and testing of the model were performed using virtual patient phantoms from two different sources. Reconstruction performance, and accuracy in estimation of breast density and radiation dose, were estimated, showing high accuracy (density <+/-3%; dose <+/-20%) without bias, significantly improving on the current state-of-the-art. This work also lays the groundwork for developing a deep learning-based reconstruction algorithm for the task of image interpretation by radiologists.Comment: Accepted in Medical Image Analysi

    ECR 2016 Book of Abstracts - D - Satellite Symposia

    Get PDF

    Optical imaging for breast cancer prescreening

    Get PDF
    Breast cancer prescreening is carried out prior to the gold standard screening using X-ray mammography and/or ultrasound. Prescreening is typically carried out using clinical breast examination (CBE) or self-breast examinations (SBEs). Since CBE and SBE have high false-positive rates, there is a need for a low-cost, noninvasive, non-radiative, and portable imaging modality that can be used as a prescreening tool to complement CBE/SBE. This review focuses on the various hand-held optical imaging devices that have been developed and applied toward early-stage breast cancer detection or as a prescreening tool via phantom, in vivo, and breast cancer imaging studies. Apart from the various optical devices developed by different research groups, a wide-field fiber-free near-infrared optical scanner has been developed for transillumination-based breast imaging in our Optical Imaging Laboratory. Preliminary in vivo studies on normal breast tissues, with absorption-contrasted targets placed in the intramammary fold, detected targets as deep as 8.8 cm. Future work involves in vivo imaging studies on breast cancer subjects and comparison with the gold standard X-ray mammography approach

    Inter-plane artifact suppression in tomosynthesis using 3D CT image data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite its superb lateral resolution, flat-panel-detector (FPD) based tomosynthesis suffers from low contrast and inter-plane artifacts caused by incomplete cancellation of the projection components stemming from outside the focal plane. The incomplete cancellation of the projection components, mostly due to the limited scan angle in the conventional tomosynthesis scan geometry, often makes the image contrast too low to differentiate the malignant tissues from the background tissues with confidence.</p> <p>Methods</p> <p>In this paper, we propose a new method to suppress the inter-plane artifacts in FPD-based tomosynthesis. If 3D whole volume CT images are available before the tomosynthesis scan, the CT image data can be incorporated into the tomosynthesis image reconstruction to suppress the inter-plane artifacts, hence, improving the image contrast. In the proposed technique, the projection components stemming from outside the region-of-interest (ROI) are subtracted from the measured tomosynthesis projection data to suppress the inter-plane artifacts. The projection components stemming from outside the ROI are calculated from the 3D whole volume CT images which usually have lower lateral resolution than the tomosynthesis images. The tomosynthesis images are reconstructed from the subtracted projection data which account for the x-ray attenuation through the ROI. After verifying the proposed method by simulation, we have performed both CT scan and tomosynthesis scan on a phantom and a sacrificed rat using a FPD-based micro-CT.</p> <p>Results</p> <p>We have measured contrast-to-noise ratio (CNR) from the tomosynthesis images which is an indicator of the residual inter-plane artifacts on the focal-plane image. In both cases of the simulation and experimental imaging studies of the contrast evaluating phantom, CNRs have been significantly improved by the proposed method. In the rat imaging also, we have observed better visual contrast from the tomosynthesis images reconstructed by the proposed method.</p> <p>Conclusions</p> <p>The proposed tomosynthesis technique can improve image contrast with aids of 3D whole volume CT images. Even though local tomosynthesis needs extra 3D CT scanning, it may find clinical applications in special situations in which extra 3D CT scan is already available or allowed.</p
    corecore