415 research outputs found

    Vascular Response to Sildenafil Citrate in Aging and Age-Related Macular Degeneration.

    Get PDF
    Age-related macular degeneration (AMD) - the leading cause of vision loss in the elderly - share many risks factors as atherosclerosis, which exhibits loss of vascular compliance resulting from aging and oxidative stress. Here, we attempt to explore choroidal and retinal vascular compliance in patients with AMD by evaluating dynamic vascular changes using live ocular imaging following treatment with oral sildenafil citrate, a phosphodiesterase type 5 (PDE5) inhibitor and potent vasodilator. Enhanced-depth imaging optical coherence tomography (EDI-OCT) and OCT angiography (OCT-A) were performed on 46 eyes of 23 subjects, including 15 patients with non-exudative AMD in one eye and exudative AMD in the fellow eye, and 8 age-matched control subjects. Choroidal thickness, choroidal vascularity, and retinal vessel density were measured across the central macula at 1 and 3 hours after a 100 mg oral dose of sildenafil citrate. Baseline choroidal thickness was 172.1 ± 60.0 μm in non-exudative AMD eyes, 196.4 ± 89.8 μm in exudative AMD eyes, and 207.4 ± 77.7 μm in control eyes, with no difference between the 3 groups (P = 0.116). After sildenafil, choroidal thickness increased by 6.0% to 9.0% at 1 and 3 hours in all groups (P = 0.001-0.014). Eyes from older subjects were associated with choroidal thinning at baseline (P = 0.005) and showed less choroidal expansion at 1 hour and 3 hours after sildenafil (P = 0.001) regardless of AMD status (P = 0.666). The choroidal thickening appeared to be primarily attributed to expansion of the stroma rather than luminal component. Retinal vascular density remained unchanged after sildenafil in all 3 groups (P = 0.281-0.587). Together, our studies suggest that vascular response of the choroid to sildenafil decreases with age, but is not affected by the presence of non-exudative or exudative AMD, providing insight into changes in vessel compliance in aging and AMD

    Imaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography.

    Get PDF
    The lamina cribrosa (LC) is the presumed site of axonal injury in glaucoma. Its deformation has been suggested to contribute to optic neuropathy by impeding axoplasmic flow within the optic nerve fibers, leading to apoptosis of retinal ganglion cells. To visualize the LC in vivo, optical coherence tomography (OCT) has been applied. Spectral domain (SD)-OCT, used in conjunction with recently introduced enhanced depth imaging (EDI)-OCT, has improved visualization of deeper ocular layers, but in many individuals it is still limited by inadequate resolution, poor image contrast and insufficient depth penetrance. The posterior laminar surface especially is not viewed clearly using these methods. New generation high-penetration (HP)-OCTs, also known as swept-source (SS)-OCT, are capable to evaluate the choroid in vivo to a remarkable level of detail. SS-OCTs use a longer wavelength (1,050 nm instead of 840 nm) compared to the conventional techniques. We review current knowledge of the LC, findings from trials that use SD-OCT and EDI-OCT, and our experience with a prototype SS-OCT to visualize the LC in its entirety. Key Points What is known? •     The LC is the presumed site of axonal injury in glaucoma •     Compared to spectral domain-OCT, enhanced depth imaging-OCT improves imaging of the LC •     Even so, currently used SD-OCT techniques are restricted by poor wavelength penetrance of the deeper ocular layers What our findings add? •    SS-OCT may be a superior imaging modality for deep ocular structures •    Prior studies used SS-OCT to evaluate choroidal thickness in both healthy and 'normal tension glaucoma' eyes •    SS-OCT enables good evaluation of three-dimension (3D) lamina cribrosa morphology. How to cite this article: Nuyen B, Mansouri K, Weinreb RN. Imaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography. J Current Glau Prac 2012;6(3): 113-119

    Characterization of Choroidal Layers in Normal Aging Eyes Using Enface Swept-Source Optical Coherence Tomography

    Get PDF
    Purpose To characterize qualitative and quantitative features of the choroid in normal eyes using enface swept-source optical coherence tomography (SS-OCT). Methods Fifty-two eyes of 26 consecutive normal subjects were prospectively recruited to obtain multiple three-dimensional 12x12mm volumetric scans using a long-wavelength high-speed SS-OCT prototype. A motion-correction algorithm merged multiple SS-OCT volumes to improve signal. Retinal pigment epithelium (RPE) was segmented as the reference and enface images were extracted at varying depths every 4.13 mu m intervals. Systematic analysis of the choroid at different depths was performed to qualitatively assess the morphology of the choroid and quantify the absolute thicknesses as well as the relative thicknesses of the choroidal vascular layers including the choroidal microvasculature (choriocapillaris, terminal arterioles and venules;CC) and choroidal vessels (CV) with respect to the subfoveal total choroidal thickness (TC). Subjects were divided into two age groups: younger (= 40 years). Results Mean age of subjects was 41.92 (24-66) years. Enface images at the level of the RPE, CC, CV, and choroidal-scleral interface were used to assess specific qualitative features. In the younger age group, the mean absolute thicknesses were: TC 379.4 mu m (SD +/- 75.7 mu m),CC 81.3 mu m (SD +/- 21.2 mu m) and CV 298.1 mu m (SD +/- 63.7 mu m). In the older group, the mean absolute thicknesses were: TC 305.0 mu m (SD +/- 50.9 mu m),CC 56.4 mu m (SD +/- 12.1 mu m) and CV 248.6 mu m (SD +/- 49.7 mu m). In the younger group, the relative thicknesses of the individual choroidal layers were: CC 21.5% (SD +/- 4.0%) and CV 78.4% (SD +/- 4.0%). In the older group, the relative thicknesses were: CC 18.9% (SD +/- 4.5%) and CV 81.1% (SD +/- 4.5%). The absolute thicknesses were smaller in the older age group for all choroidal layers (TC p=0.006, CC p=0.0003, CV p=0.03) while the relative thickness was smaller only for the CC (p=0.04). Conclusions Enface SS-OCT at 1050nm enables a precise qualitative and quantitative characterization of the individual choroidal layers in normal eyes. Only the CC is relatively thinner in the older eyes. In-vivo evaluation of the choroid at variable depths may be potentially valuable in understanding the natural history of age-related posterior segment disease

    Effect of Uveal Melanocytes on Choroidal Morphology in Rhesus Macaques and Humans on Enhanced-Depth Imaging Optical Coherence Tomography.

    Get PDF
    PurposeTo compare cross-sectional choroidal morphology in rhesus macaque and human eyes using enhanced-depth imaging optical coherence tomography (EDI-OCT) and histologic analysis.MethodsEnhanced-depth imaging-OCT images from 25 rhesus macaque and 30 human eyes were evaluated for choriocapillaris and choroidal-scleral junction (CSJ) visibility in the central macula based on OCT reflectivity profiles, and compared with age-matched histologic sections. Semiautomated segmentation of the choriocapillaris and CSJ was used to measure choriocapillary and choroidal thickness, respectively. Multivariate regression was performed to determine the association of age, refractive error, and race with choriocapillaris and CSJ visibility.ResultsRhesus macaques exhibit a distinct hyporeflective choriocapillaris layer on EDI-OCT, while the CSJ cannot be visualized. In contrast, humans show variable reflectivities of the choriocapillaris, with a distinct CSJ seen in many subjects. Histologic sections demonstrate large, darkly pigmented melanocytes that are densely distributed in the macaque choroid, while melanocytes in humans are smaller, less pigmented, and variably distributed. Optical coherence tomography reflectivity patterns of the choroid appear to correspond to the density, size, and pigmentation of choroidal melanocytes. Mean choriocapillary thickness was similar between the two species (19.3 ± 3.4 vs. 19.8 ± 3.4 μm, P = 0.615), but choroidal thickness may be lower in macaques than in humans (191.2 ± 43.0 vs. 266.8 ± 78.0 μm, P < 0.001). Racial differences in uveal pigmentation also appear to affect the visibility of the choriocapillaris and CSJ on EDI-OCT.ConclusionsPigmented uveal melanocytes affect choroidal morphology on EDI-OCT in rhesus macaque and human eyes. Racial differences in pigmentation may affect choriocapillaris and CSJ visibility, and may influence the accuracy of choroidal thickness measurements

    Angiography of the retina and the choroid with phase-resolved OCT using interval-optimized backstitched B-scans

    Get PDF
    In conventional phase-resolved OCT blood flow is detected from phase changes between successive A-scans. Especially in high-speed OCT systems this results in a short evaluation time interval. This method is therefore often unable to visualize complete vascular networks since low flow velocities cause insufficient phase changes. This problem was solved by comparing B-scans instead of successive A-scans to enlarge the time interval. In this paper a detailed phase-noise analysis of our OCT system is presented in order to calculate the optimal time intervals for visualization of the vasculature of the human retina and choroid. High-resolution images of the vasculature of a healthy volunteer taken with various time intervals are presented to confirm this analysis. The imaging was performed with a backstitched B-scan in which pairs of small repeated B-scans are stitched together to independently control the time interval and the imaged lateral field size. A time interval of ≥2.5 ms was found effective to image the retinal vasculature down to the capillary level. The higher flow velocities of the choroid allowed a time interval of 0.64 ms to reveal its dense vasculature. Finally we analyzed depth-resolved histograms of volumetric phase-difference data to assess changes in amount of blood flow with depth. This analysis indicated different flow regimes in the retina and the choroid. © 2012 Optical Society of America

    Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye

    Get PDF
    Retinal vascular diseases are important causes of vision loss. A detailed evaluation of the vascular abnormalities facilitates diagnosis and treatment in these diseases. Optical coherence tomography (OCT) angiography using the highly efficient split-spectrum amplitude decorrelation angiography algorithm offers an alternative to conventional dye-based retinal angiography. OCT angiography has several advantages, including 3D visualization of retinal and choroidal circulations (including the choriocapillaris) and avoidance of dye injection-related complications. Results from six illustrative cases are reported. In diabetic retinopathy, OCT angiography can detect neovascularization and quantify ischemia. In age-related macular degeneration, choroidal neovascularization can be observed without the obscuration of details caused by dye leakage in conventional angiography. Choriocapillaris dysfunction can be detected in the nonneovascular form of the disease, furthering our understanding of pathogenesis. In choroideremia, OCT's ability to show choroidal and retinal vascular dysfunction separately may be valuable in predicting progression and assessing treatment response. OCT angiography shows promise as a noninvasive alternative to dye-based angiography for highly detailed, in vivo, 3D, quantitative evaluation of retinal vascular abnormalities.National Institutes of Health (U.S.) (Grant R01-EY023285)National Institutes of Health (U.S.) (Grant R01-EY024544)National Institutes of Health (U.S.) (Grant DP3 DK104397)National Institutes of Health (U.S.) (Grant R01-EY11289)National Institutes of Health (U.S.) (Grant K08-EY021186)National Institutes of Health (U.S.) (Grant T32-EY23211)National Institutes of Health (U.S.) (Grant P30-EY010572)Clinical and Translational Science Award Grant UL1TR000128Research to Prevent Blindness, Inc. (United States) (Grant and Career Development Award CD-NMT-0914-0659-OHSU)United States. Air Force Office of Scientific Research (Foundation Fighting Blindness Career Development Award FA9550-10-1-0551)German Research Foundation (Grant DFG-HO-1791/11-1)German Research Foundation (Grant DFG-GSC80-SAOT

    Application of ImageJ in Optical Coherence Tomography Angiography (OCT-A): A Literature Review

    Get PDF
    Background. This study aimed to review the literature on the application of ImageJ in optical coherence tomography angiography (OCT-A) images. Methods. A general search was performed in PubMed, Google Scholar, and Scopus databases. The authors evaluated each of the selected articles in order to assess the implementation of ImageJ in OCT-A images. Results. ImageJ can aid in reducing artifacts, enhancing image quality to increase the accuracy of the process and analysis, processing and analyzing images, generating comparable parameters such as the parameters that assess perfusion of the layers (vessel density (VD), skeletonized density (SD), and vessel length density (VLD)) and the parameters that evaluate the structure of the layers (fractal dimension (FD), vessel density index (VDI), and lacunarity (LAC)), and the foveal avascular zone (FAZ) that are used widely in the retinal and choroidal studies), and establishing diagnostic criteria. It can help to save time when the dataset is huge with numerous plugins and options for image processing and analysis with reliable results. Diverse studies implemented distinct binarization and thresholding techniques, resulting in disparate outcomes and incomparable parameters. Uniformity in methodology is required to acquire comparable data from studies employing diverse processing and analysis techniques that yield varied outcomes. Conclusion. Researchers and professionals might benefit from using ImageJ because of how quickly and correctly it processes and analyzes images. It is highly adaptable and potent software, allowing users to evaluate images in a variety of ways. There exists a diverse range of methodologies for analyzing OCTA images through the utilization of ImageJ. However, it is imperative to establish a standardized strategy to ensure the reliability and consistency of the method for research purposes

    Enhanced imaging of choroidal vasculature by high-penetration and dual-velocity optical coherence angiography

    Get PDF
    Dual-beam-scan Doppler optical coherence angiography (DB-OCA) with a 1-μm-wavelength probe is demonstrated for improved in vivo choroidal angiograms of the human eye. This method utilizes two scanning beams with spatial and temporal separation on the retina, and provides two measurable velocity ranges. The method achieves higher sensitivity to very low velocity flows than conventional Doppler optical coherence tomography. Moreover, longer wavelengths allowing greater penetration, enhanced visualization of choroidal vessels is verified with en-face projection images of the Doppler shift squared. Specifically, better choroidal vasculature visibility is achieved at a wavelength of 1 μm than at 840 nm

    Choroidal Imaging Using Spectral-Domain Optical Coherence Tomography

    Get PDF
    Author Manuscript received 2012 June 22.Background: A structurally and functionally normal choroidal vasculature is essential for retinal function. Therefore, a precise clinical understanding of choroidal morphology should be important for understanding many retinal and choroidal diseases. Methods: PUBMED ( http://www.ncbi.nlm.nih.gov/site...) was used for most of the literature search for this article. The criterion for inclusion of an article in the references for this review was that it included materials about both the clinical and the basic properties of choroidal imaging using spectral-domain optical coherence tomography. Results: Recent reports show successful examination and accurate measurement of choroidal thickness in normal and pathologic states using spectral-domain optical coherence tomography systems. This review focuses on the principles of the new technology that make choroidal imaging using optical coherence tomography possible and on the changes that subsequently have been documented to occur in the choroid in various diseases. Additionally, it outlines future directions in choroidal imaging. Conclusion: Optical coherence tomography is now proven to be an effective noninvasive tool to evaluate the choroid and to detect choroidal changes in pathologic states. Additionally, choroidal evaluation using optical coherence tomography can be used as a parameter for diagnosis and follow-up.Research to Prevent Blindness, Inc. (United States) (Unrestricted Grant)National Institutes of Health (U.S.) (Contract RO1-EY11289-25)National Institutes of Health (U.S.) (Contract R01-EY13178-10)National Institutes of Health (U.S.) (Contract R01-EY013516-07)National Institutes of Health (U.S.) (Contract R01-EY019029-02)United States. Air Force Office of Scientific Research (Grant FA9550-10-1-0551)United States. Air Force Office of Scientific Research (FA9550-10-1-0063
    • …
    corecore