4,630 research outputs found

    Chemical Sensing Using Fiber Cavity Ring-Down Spectroscopy

    Get PDF
    Waveguide-based cavity ring-down spectroscopy (CRD) can be used for quantitative measurements of chemical concentrations in small amounts of liquid, in gases or in films. The change in ring-down time can be correlated to analyte concentration when using fiber optic sensing elements that change their attenuation in dependence of either sample absorption or refractive index. Two types of fiber cavities, i.e., fiber loops and fiber strands containing reflective elements, are distinguished. Both types of cavities were coupled to a variety of chemical sensor elements, which are discussed and compared

    On-chip mid-infrared photothermal spectroscopy using suspended silicon-on-insulator microring resonators

    Get PDF
    Mid-infrared spectroscopic techniques rely on the specific "fingerprint" absorption lines of molecules in the mid-infrared band to detect the presence and concentration of these molecules. Despite being very sensitive and selective, bulky and expensive equipment such as cooled mid-infrared detectors is required for conventional systems. In this paper, we demonstrate a miniature CMOS-compatible Silicon-on-Insulator (SOI) photothermal transducer for mid-infrared spectroscopy which can potentially be made in high volumes and at a low cost. The optical absorption of an analyte in the mid infrared wavelength range (3.25-3.6 mu m) is thermally transduced to an optical transmission change of a microring resonator through the thermo-optic effect in silicon. The photothermal signal is further enhanced by locally removing the silicon substrate beneath the transducer, hereby increasing the effective thermal isolation by a factor of 40. As a proof-of-concept, the absorption spectrum of a polymer that has been locally patterned in the annular region of the resonator was recovered using photothermal spectroscopy. The spectrum is in good agreement with a benchmark Fourier-transform infrared spectroscopy (FTIR) measurement. A normalized noise equivalent absorption coefficient (NNEA) of 7.6 X 10(-6) W/Hz(1/2) is estimated

    Optical sensors using chaotic correlation fiber loop ring down

    Get PDF
    We have proposed a novel optical sensor scheme based on chaotic correlation fiber loop ring down (CCFLRD). In contrast to the well-known FLRD spectroscopy, where pulsed laser is injected to fiber loop and ring down time is measured, the proposed CCFLRD uses a chaotic laser to drive a fiber loop and measures autocorrelation coefficient ring down time of chaotic laser. The fundamental difference enables us to avoid using long fiber loop as required in pulsed FLRD, and thus generates higher sensitivity. A strain sensor has been developed to validate the CCFLRD concept. Theoretical and experiment results demonstrate that the proposed method is able to enhance sensitivity by more than two orders of magnitude comparing to the existing FLRD method. We believe the proposed method could find great potential applications for chemical, medical, and physical sensing

    Intra-cavity spectroscopy using amplified spontaneous emission in fiber lasers

    Get PDF
    Fiber laser sources offer interesting possibilities for gas sensors since they can operate over an extended wavelength range, encompassing the near-IR absorption lines of a number of important gases but a major problem is that overtone absorption lines of gases in the near-IR are relatively weak. In order to enhance sensitivity, we present here a simple method of intra-cavity absorption spectroscopy (ICAS) which makes use of the amplified spontaneous emission (ASE) already present within a fiber laser cavity. The ASE also provides a convenient broadband source for the simultaneous interrogation of several gases within the gain-bandwidth of the fiber laser. The key principle is based on adjusting the cavity attenuation to select an appropriate inversion level where the fiber gain curve is flat. Under this condition, the ASE undergoes multiple circulations within the fiber laser cavity, enhancing the effective path-length of a gas cell placed within the laser cavity. A theoretical model of system operation is given and we have experimentally demonstrated the principle of operation with acetylene and carbon dioxide using a simple erbium fiber laser system containing a 6 cm path-length, fiber coupled, intra-cavity, micro-optic gas cell. We have experimentally simultaneously observed 16 absorption lines for 1% acetylene gas in the 1530 nm region and detected the very weak carbon dioxide lines in this same wavelength region. A path length enhancement of in the linear regime has been demonstrated transforming the 6 cm micro-optic cell into an effective path length of m. We also demonstrate how the enhancement factor may be calibrated by use of a simple fiber-optic interferometer. Apart from the OSA, all components are inexpensive and the system is very simple to construct and operate