747 research outputs found

    Mammographic density. Measurement of mammographic density

    Get PDF
    Mammographic density has been strongly associated with increased risk of breast cancer. Furthermore, density is inversely correlated with the accuracy of mammography and, therefore, a measurement of density conveys information about the difficulty of detecting cancer in a mammogram. Initial methods for assessing mammographic density were entirely subjective and qualitative; however, in the past few years methods have been developed to provide more objective and quantitative density measurements. Research is now underway to create and validate techniques for volumetric measurement of density. It is also possible to measure breast density with other imaging modalities, such as ultrasound and MRI, which do not require the use of ionizing radiation and may, therefore, be more suitable for use in young women or where it is desirable to perform measurements more frequently. In this article, the techniques for measurement of density are reviewed and some consideration is given to their strengths and limitations

    Mammography Techniques and Review

    Get PDF
    Mammography remains at the backbone of medical tools to examine the human breast. The early detection of breast cancer typically uses adjunct tests to mammogram such as ultrasound, positron emission mammography, electrical impedance, Computer-aided detection systems and others. In the present digital era it is even more important to use the best new techniques and systems available to improve the correct diagnosis and to prevent mortality from breast cancer. The first part of this book deals with the electrical impedance mammographic scheme, ultrasound axillary imaging, position emission mammography and digital mammogram enhancement. A detailed consideration of CBR CAD System and the availability of mammographs in Brazil forms the second part of this book. With the up-to-date papers from world experts, this book will be invaluable to anyone who studies the field of mammography

    Effective x-ray attenuation coefficient measurements from two full field digital mammography systems for data calibration applications

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Breast density is a significant breast cancer risk factor. Currently, there is no standard method for measuring this important factor. Work presented here represents an essential component of an ongoing project that seeks to determine the appropriate method for calibrating (standardizing) mammography image data to account for the x-ray image acquisition influences. Longer term goals of this project are to make accurate breast density measurements in support of risk studies.</p> <p>Methods</p> <p>Logarithmic response calibration curves and effective x-ray attenuation coefficients were measured from two full field digital mammography (FFDM) systems with breast tissue equivalent phantom imaging and compared. Normalization methods were studied to assess the possibility of reducing the amount of calibration data collection. The percent glandular calibration map functional form was investigated. Spatial variations in the calibration data were used to assess the uncertainty in the calibration application by applying error propagation analyses.</p> <p>Results</p> <p>Logarithmic response curves are well approximated as linear. Measured effective x-ray attenuation coefficients are characteristic quantities independent of the imaging system and are in agreement with those predicted numerically. Calibration data collection can be reduced by applying a simple normalization technique. The calibration map is well approximated as linear. Intrasystem calibration variation was on the order of four percent, which was approximately half of the intersystem variation.</p> <p>Conclusion</p> <p>FFDM systems provide a quantitative output, and the calibration quantities presented here may be used for data acquired on similar FFDM systems.</p

    Mammographic density, breast cancer risk and risk prediction

    Get PDF
    In this review, we examine the evidence for mammographic density as an independent risk factor for breast cancer, describe the risk prediction models that have incorporated density, and discuss the current and future implications of using mammographic density in clinical practice. Mammographic density is a consistent and strong risk factor for breast cancer in several populations and across age at mammogram. Recently, this risk factor has been added to existing breast cancer risk prediction models, increasing the discriminatory accuracy with its inclusion, albeit slightly. With validation, these models may replace the existing Gail model for clinical risk assessment. However, absolute risk estimates resulting from these improved models are still limited in their ability to characterize an individual's probability of developing cancer. Promising new measures of mammographic density, including volumetric density, which can be standardized using full-field digital mammography, will likely result in a stronger risk factor and improve accuracy of risk prediction models

    Extra patient movement during mammographic imaging : an experimental study

    Get PDF
    Objectives: To determine if movement external to the patient occurring during mammography may be a source of image blur. Methods: Four mammography machines with seven flexible and nine fixed paddles were evaluated. In the first stage, movement at the paddle was measured mechanically using two calibrated linear potentiometers. A deformable breast phantom was used to mimic a female breast. For each paddle, the movement in millimeters and change in compression force in Newton was recorded at 0.5 and 1 second intervals respectively for 40 seconds with the phantom in an initially compressed state under a load of 80N. In the second stage, clinical audit on 28 females was conducted on one mammography machine with the 18x24cm and 24x29cm flexible paddles. Results: Movement at the paddle followed an exponential decay with a settling period of approximately 40 seconds. The compression force readings for both fixed and flexible paddles decreased exponentially with time while fixed paddles have a larger drop in compression force than flexible paddles. There is a linear relationship between movement at the paddle and change in compression force. Conclusions: Movement measured at the paddle during an exposure can be represented by a second order system. The amount of extra-patient movement during the actual exposure can be estimated using the linear relationship between movement at the paddle and the change in compression force. Advances in knowledge: This research provides a possible explanation to mammography image blurring caused by extra patient movement and proposes a theoretical model to analyze the movement

    Optimetric analysis of 1x4 array of circular microwave patch antennas for mammographic applications using adaptive gradient descent algorithm

    Get PDF
    Interest in the use of microwave equipment for breast imagery is on the increase owing to its safety, ease of use and friendlier cost. However, some of the pertinent blights of the design and optimization of microwave antenna include intensive consumption of computing resources, high price of software acquisition and very large optimization time. This paper therefore attempts to address these concerns by devising a rapid means of designing and optimizing the performance of a 1×4 array of circular microwave patch antenna for breast imagery applications by deploying the adaptive gradient descent algorithm (AGDA) for a circumspectly designed artificial neural network. In order to cross validate the findings of this work, the results obtained using the adaptive gradient descent algorithm was compared with those obtained with the deployment of the much reported Levenberg-Marquardt algorithm for the same dataset over same frequency range and training constraints. Analysis of the performance of the AGDA neural network shows that the approach is a viable and accurate technique for rapid design and analysis of arrays of circular microwave patch antenna for breast imaging

    Imaging of the Breast

    Get PDF
    Early detection of breast cancer combined with targeted therapy offers the best outcome for breast cancer patients. This volume deal with a wide range of new technical innovations for improving breast cancer detection, diagnosis and therapy. There is a special focus on improvements in mammographic image quality, image analysis, magnetic resonance imaging of the breast and molecular imaging. A chapter on targeted therapy explores the option of less radical postoperative therapy for women with early, screen-detected breast cancers

    Optimetric analysis of 1x4 array of circular microwave patch antennas for mammographic applications using adaptive gradient descent algorithm

    Get PDF
    Interest in the use of microwave equipment for breast imagery is on the increase owing to its safety, ease of use and friendlier cost. However, some of the pertinent blights of the design and optimization of microwave antenna include intensive consumption of computing resources, high price of software acquisition and very large optimization time. This paper therefore attempts to address these concerns by devising a rapid means of designing and optimizing the performance of a 1×4 array of circular microwave patch antenna for breast imagery applications by deploying the adaptive gradient descent algorithm (AGDA) for a circumspectly designed artificial neural network. In order to cross validate the findings of this work, the results obtained using the adaptive gradient descent algorithm was compared with those obtained with the deployment of the much reported Levenberg-Marquardt algorithm for the same dataset over same frequency range and training constraints. Analysis of the performance of the AGDA neural network shows that the approach is a viable and accurate technique for rapid design and analysis of arrays of circular microwave patch antenna for breast imaging
    corecore