35 research outputs found
Cable-driven robotic interface for lower limb neuromechanics identification.
This paper presents a versatile cable-driven robotic interface to investigate the single-joint joint neuromechanics of the hip, knee and ankle in the sagittal plane. This endpoint-based interface offers highly dynamic interaction and accurate position control (as is typically required for neuromechanics identification), and provides measurements of position, interaction force and EMG of leg muscles. It can be used with the subject upright, corresponding to a natural posture during walking or standing, and does not impose kinematic constraints on a joint, in contrast to existing interfaces. Mechanical evaluations demonstrated that the interface yields a rigidity above 500 N/m with low viscosity. Tests with a rigid dummy leg and linear springs show that it can identify the mechanical impedance of a limb accurately. A smooth perturbation is developed and tested with a human subject, which can be used to estimate the hip neuromechanics
The Influence of Posture, Applied Force and Perturbation Direction on Hip Joint Viscoelasticity.
Limb viscoelasticity is a critical neuromechanical factor used to regulate the interaction with the environment. It plays a key role in modelling human sensorimotor control, and can be used to assess the condition of healthy and neurologically affected individuals. This paper reports the estimation of hip joint viscoelasticity during voluntary force control using a novel device that applies a leg displacement without constraining the hip joint. The influence of hip angle, applied limb force and perturbation direction on the stiffness and viscosity values was studied in ten subjects. No difference was detected in the hip joint stiffness between the dominant and non-dominant legs, but a small dependency was observed on the perturbation direction. Both hip stiffness and viscosity increased monotonically with the applied force magnitude, with posture being observed to have a slight influence. These results are in line with previous measurements carried out on upper limbs, and can be used as a baseline for lower limb movement simulation and further neuromechanical investigations
On Neuromechanical Approaches for the Study of Biological Grasp and Manipulation
Biological and robotic grasp and manipulation are undeniably similar at the
level of mechanical task performance. However, their underlying fundamental
biological vs. engineering mechanisms are, by definition, dramatically
different and can even be antithetical. Even our approach to each is
diametrically opposite: inductive science for the study of biological systems
vs. engineering synthesis for the design and construction of robotic systems.
The past 20 years have seen several conceptual advances in both fields and the
quest to unify them. Chief among them is the reluctant recognition that their
underlying fundamental mechanisms may actually share limited common ground,
while exhibiting many fundamental differences. This recognition is particularly
liberating because it allows us to resolve and move beyond multiple paradoxes
and contradictions that arose from the initial reasonable assumption of a large
common ground. Here, we begin by introducing the perspective of neuromechanics,
which emphasizes that real-world behavior emerges from the intimate
interactions among the physical structure of the system, the mechanical
requirements of a task, the feasible neural control actions to produce it, and
the ability of the neuromuscular system to adapt through interactions with the
environment. This allows us to articulate a succinct overview of a few salient
conceptual paradoxes and contradictions regarding under-determined vs.
over-determined mechanics, under- vs. over-actuated control, prescribed vs.
emergent function, learning vs. implementation vs. adaptation, prescriptive vs.
descriptive synergies, and optimal vs. habitual performance. We conclude by
presenting open questions and suggesting directions for future research. We
hope this frank assessment of the state-of-the-art will encourage and guide
these communities to continue to interact and make progress in these important
areas
Design, characterisation and validation of a haptic interface based on twisted string actuation.
This paper presents the design and experimental characterisation of a wrist haptic interface based on a twisted string actuator. The interface is designed for controlled actuation of wrist flexion/extension and is capable of rendering torque feedback through a rotary handle driven by the twisted string actuator and spring-loaded cable mechanisms. The interface was characterised to obtain its static and dynamic haptic feedback rendering capabilities. Compliance in the spring and actuation mechanism makes the interface suitable for smooth rendering of haptic feedback of large magnitudes due to the high motion transmission ratio of the twisted strings. Haptic virtual wall rendering capabilities are demonstrated
On neuromechanical approaches for the study of biological and robotic grasp and manipulation
abstract: Biological and robotic grasp and manipulation are undeniably similar at the level of mechanical task performance. However, their underlying fundamental biological vs. engineering mechanisms are, by definition, dramatically different and can even be antithetical. Even our approach to each is diametrically opposite: inductive science for the study of biological systems vs. engineering synthesis for the design and construction of robotic systems. The past 20 years have seen several conceptual advances in both fields and the quest to unify them. Chief among them is the reluctant recognition that their underlying fundamental mechanisms may actually share limited common ground, while exhibiting many fundamental differences. This recognition is particularly liberating because it allows us to resolve and move beyond multiple paradoxes and contradictions that arose from the initial reasonable assumption of a large common ground. Here, we begin by introducing the perspective of neuromechanics, which emphasizes that real-world behavior emerges from the intimate interactions among the physical structure of the system, the mechanical requirements of a task, the feasible neural control actions to produce it, and the ability of the neuromuscular system to adapt through interactions with the environment. This allows us to articulate a succinct overview of a few salient conceptual paradoxes and contradictions regarding under-determined vs. over-determined mechanics, under- vs. over-actuated control, prescribed vs. emergent function, learning vs. implementation vs. adaptation, prescriptive vs. descriptive synergies, and optimal vs. habitual performance. We conclude by presenting open questions and suggesting directions for future research. We hope this frank and open-minded assessment of the state-of-the-art will encourage and guide these communities to continue to interact and make progress in these important areas at the interface of neuromechanics, neuroscience, rehabilitation and robotics.The electronic version of this article is the complete one and can be found online at: https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-017-0305-
Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton
This paper presents design principles for comfort-centered wearable robots
and their application in a lightweight and backdrivable knee exoskeleton. The
mitigation of discomfort is treated as mechanical design and control issues and
three solutions are proposed in this paper: 1) a new wearable structure
optimizes the strap attachment configuration and suit layout to ameliorate
excessive shear forces of conventional wearable structure design; 2) rolling
knee joint and double-hinge mechanisms reduce the misalignment in the sagittal
and frontal plane, without increasing the mechanical complexity and inertia,
respectively; 3) a low impedance mechanical transmission reduces the reflected
inertia and damping of the actuator to human, thus the exoskeleton is
highly-backdrivable. Kinematic simulations demonstrate that misalignment
between the robot joint and knee joint can be reduced by 74% at maximum knee
flexion. In experiments, the exoskeleton in the unpowered mode exhibits 1.03 Nm
root mean square (RMS) low resistive torque. The torque control experiments
demonstrate 0.31 Nm RMS torque tracking error in three human subjects.Comment: 8 pages, 16figures, Journa
Application of wearable sensors in actuation and control of powered ankle exoskeletons: a Comprehensive Review
Powered ankle exoskeletons (PAEs) are robotic devices developed for gait assistance, rehabilitation, and augmentation. To fulfil their purposes, PAEs vastly rely heavily on their sensor systems. Human–machine interface sensors collect the biomechanical signals from the human user to inform the higher level of the control hierarchy about the user’s locomotion intention and requirement, whereas machine–machine interface sensors monitor the output of the actuation unit to ensure precise tracking of the high-level control commands via the low-level control scheme. The current article aims to provide a comprehensive review of how wearable sensor technology has contributed to the actuation and control of the PAEs developed over the past two decades. The control schemes and actuation principles employed in the reviewed PAEs, as well as their interaction with the integrated sensor systems, are investigated in this review. Further, the role of wearable sensors in overcoming the main challenges in developing fully autonomous portable PAEs is discussed. Finally, a brief discussion on how the recent technology advancements in wearable sensors, including environment—machine interface sensors, could promote the future generation of fully autonomous portable PAEs is provided
Relevance of hazards in exoskeleton applications: a survey-based enquiry
Exoskeletons are becoming the reference technology for assistance and augmentation of human motor functions in a wide range of application domains. Unfortunately, the exponential growth of this sector has not been accompanied by a rigorous risk assessment (RA) process, which is necessary to identify the major aspects concerning the safety and impact of this new technology on humans. This situation may seriously hamper the market uptake of new products. This paper presents the results of a survey that was circulated to understand how hazards are considered by exoskeleton users, from research and industry perspectives. Our analysis aimed to identify the perceived occurrence and the impact of a sample of generic hazards, as well as to collect suggestions and general opinions from the respondents that can serve as a reference for more targeted RA. Our results identified a list of relevant hazards for exoskeletons. Among them, misalignments and unintended device motion were perceived as key aspects for exoskeletons' safety. This survey aims to represent a first attempt in recording overall feedback from the community and contribute to future RAs and the identification of better mitigation strategies in the field
Metabolically efficient walking assistance using optimized timed forces at the waist
The metabolic rate of walking can be reduced by applying a constant forward force at the center of mass. It has been shown that the metabolically optimal constant force magnitude minimizes propulsion ground reaction force at the expense of increased braking. This led to the hypothesis that selectively assisting propulsion could lead to greater benefits. We used a robotic waist tether to evaluate the effects of forward forces with different timings and magnitudes. Here, we show that it is possible to reduce the metabolic rate of healthy participants by 48% with a greater efficiency ratio of metabolic cost reduction per unit of net aiding work compared with other assistive robots. This result was obtained using a sinusoidal force profile with peak timing during the middle of the double support. The same timing could also reduce the metabolic rate in patients with peripheral artery disease. A model explains that the optimal force profile accelerates the center of mass into the inverted pendulum movement during single support. Contrary to the hypothesis, the optimal force timing did not entirely coincide with propulsion. Within the field of wearable robotics, there is a trend to use devices to mimic biological torque or force profiles. Such bioinspired actuation can have relevant benefits; however, our results demonstrate that this is not necessarily optimal for reducing metabolic rate