933 research outputs found

    Accurate and reliable segmentation of the optic disc in digital fundus images

    Get PDF
    We describe a complete pipeline for the detection and accurate automatic segmentation of the optic disc in digital fundus images. This procedure provides separation of vascular information and accurate inpainting of vessel-removed images, symmetry-based optic disc localization, and fitting of incrementally complex contour models at increasing resolutions using information related to inpainted images and vessel masks. Validation experiments, performed on a large dataset of images of healthy and pathological eyes, annotated by experts and partially graded with a quality label, demonstrate the good performances of the proposed approach. The method is able to detect the optic disc and trace its contours better than the other systems presented in the literature and tested on the same data. The average error in the obtained contour masks is reasonably close to the interoperator errors and suitable for practical applications. The optic disc segmentation pipeline is currently integrated in a complete software suite for the semiautomatic quantification of retinal vessel properties from fundus camera images (VAMPIRE)

    Detection and Classification of Diabetic Retinopathy Pathologies in Fundus Images

    Get PDF
    Diabetic Retinopathy (DR) is a disease that affects up to 80% of diabetics around the world. It is the second greatest cause of blindness in the Western world, and one of the leading causes of blindness in the U.S. Many studies have demonstrated that early treatment can reduce the number of sight-threatening DR cases, mitigating the medical and economic impact of the disease. Accurate, early detection of eye disease is important because of its potential to reduce rates of blindness worldwide. Retinal photography for DR has been promoted for decades for its utility in both disease screening and clinical research studies. In recent years, several research centers have presented systems to detect pathology in retinal images. However, these approaches apply specialized algorithms to detect specific types of lesion in the retina. In order to detect multiple lesions, these systems generally implement multiple algorithms. Furthermore, some of these studies evaluate their algorithms on a single dataset, thus avoiding potential problems associated with the differences in fundus imaging devices, such as camera resolution. These methodologies primarily employ bottom-up approaches, in which the accurate segmentation of all the lesions in the retina is the basis for correct determination. A disadvantage of bottom-up approaches is that they rely on the accurate segmentation of all lesions in order to measure performance. On the other hand, top-down approaches do not depend on the segmentation of specific lesions. Thus, top-down methods can potentially detect abnormalities not explicitly used in their training phase. A disadvantage of these methods is that they cannot identify specific pathologies and require large datasets to build their training models. In this dissertation, I merged the advantages of the top-down and bottom-up approaches to detect DR with high accuracy. First, I developed an algorithm based on a top-down approach to detect abnormalities in the retina due to DR. By doing so, I was able to evaluate DR pathologies other than microaneurysms and exudates, which are the main focus of most current approaches. In addition, I demonstrated good generalization capacity of this algorithm by applying it to other eye diseases, such as age-related macular degeneration. Due to the fact that high accuracy is required for sight-threatening conditions, I developed two bottom-up approaches, since it has been proven that bottom-up approaches produce more accurate results than top-down approaches for particular structures. Consequently, I developed an algorithm to detect exudates in the macula. The presence of this pathology is considered to be a surrogate for clinical significant macular edema (CSME), a sight-threatening condition of DR. The analysis of the optic disc is usually not taken into account in DR screening systems. However, there is a pathology called neovascularization that is present in advanced stages of DR, making its detection of crucial clinical importance. In order to address this problem, I developed an algorithm to detect neovascularization in the optic disc. These algorithms are based on amplitude-modulation and frequency-modulation (AM-FM) representations, morphological image processing methods, and classification algorithms. The methods were tested on a diverse set of large databases and are considered to be the state-of the art in this field

    Retinal Fundus Image Analysis for Diagnosis of Glaucoma: A Comprehensive Survey

    Full text link
    © 2016 IEEE. The rapid development of digital imaging and computer vision has increased the potential of using the image processing technologies in ophthalmology. Image processing systems are used in standard clinical practices with the development of medical diagnostic systems. The retinal images provide vital information about the health of the sensory part of the visual system. Retinal diseases, such as glaucoma, diabetic retinopathy, age-related macular degeneration, Stargardt's disease, and retinopathy of prematurity, can lead to blindness manifest as artifacts in the retinal image. An automated system can be used for offering standardized large-scale screening at a lower cost, which may reduce human errors, provide services to remote areas, as well as free from observer bias and fatigue. Treatment for retinal diseases is available; the challenge lies in finding a cost-effective approach with high sensitivity and specificity that can be applied to large populations in a timely manner to identify those who are at risk at the early stages of the disease. The progress of the glaucoma disease is very often quiet in the early stages. The number of people affected has been increasing and patients are seldom aware of the disease, which can cause delay in the treatment. A review of how computer-aided approaches may be applied in the diagnosis and staging of glaucoma is discussed here. The current status of the computer technology is reviewed, covering localization and segmentation of the optic nerve head, pixel level glaucomatic changes, diagonosis using 3-D data sets, and artificial neural networks for detecting the progression of the glaucoma disease

    Exudate detection in color retinal images for mass screening of diabetic retinopathy

    No full text
    International audienceThe automatic detection of exudates in colour eye fundus images is an important task in applications such as diabetic retinopathy screening. The presented work has been undertaken in the framework of the TeleOphta project, whose main objective is to auto-matically detect normal exams in a tele-ophthalmology network, thus reducing the burden on the readers. A new clinical database, e-ophtha EX, containing precisely manually contoured exudates, is introduced. As opposed to previously available databases, e-ophtha EX is very heterogeneous. It contains images gathered within the OPHDIAT telemedicine network for diabetic retinopathy screening. Image definition, quality, as well as patients condition or the retinograph used for the acquisition, for example, are subject to important changes between different examinations. The proposed exudate detection method has been designed for this complex situation. We propose new preprocessing methods, which perform not only normalization and denoising tasks, but also de-tect reflections and artifacts in the image. A new candidates segmentation method, based on mathematical morphology, is proposed. These candidates are characterized using classical features, but also novel contextual features. Finally, a random forest algorithm is used to detect the exudates among the candidates. The method has been validated on the e-ophtha EX database, obtaining an AUC of 0.95. It has been also validated on other databases, obtaining an AUC between 0.93 and 0.95, outperforming state-of-the-art methods

    Automated retinal analysis

    Get PDF
    Diabetes is a chronic disease affecting over 2% of the population in the UK [1]. Long-term complications of diabetes can affect many different systems of the body including the retina of the eye. In the retina, diabetes can lead to a disease called diabetic retinopathy, one of the leading causes of blindness in the working population of industrialised countries. The risk of visual loss from diabetic retinopathy can be reduced if treatment is given at the onset of sight-threatening retinopathy. To detect early indicators of the disease, the UK National Screening Committee have recommended that diabetic patients should receive annual screening by digital colour fundal photography [2]. Manually grading retinal images is a subjective and costly process requiring highly skilled staff. This thesis describes an automated diagnostic system based oil image processing and neural network techniques, which analyses digital fundus images so that early signs of sight threatening retinopathy can be identified. Within retinal analysis this research has concentrated on the development of four algorithms: optic nerve head segmentation, lesion segmentation, image quality assessment and vessel width measurements. This research amalgamated these four algorithms with two existing techniques to form an integrated diagnostic system. The diagnostic system when used as a 'pre-filtering' tool successfully reduced the number of images requiring human grading by 74.3%: this was achieved by identifying and excluding images without sight threatening maculopathy from manual screening

    Eye Disease Detection Using Computer Vision

    Get PDF
    Glaucoma and Diabetic Retinopathy(DR) are among the leading causes of blindness. Belated handling of Cataract can impact the vision causing blindness. Often the scarcity of experts can lead to delayed diagnosis, resulting in untreatable conditions. But detection of these diseases at earliest stage and treatment can aid patient in avoiding vision loss. An automatic disease detection system can help this by providing accurate and early diagnosis. In proposed system, diagnosis will be obtained using image processing and mining techniques on fundus image. Feature extraction using DCT. K-NN classification algorithm will be used to classify the image in a specific class (Normal,Glaucoma,DR or Cataract)

    Deep learning based approach for optic disc and optic cup semantic segmentation for glaucoma analysis in retinal fundus images

    Get PDF
    Optic disc and optic cup are one of the most recognized retinal landmarks, and there are numerous methods for their automatic detection. Segmented optic disc and optic cup are useful in providing the contextual information about the retinal image that can aid in the detection of other retinal features, but it is also useful in the automatic detection and monitoring of glaucoma. This paper proposes a deep learning based approach for the automatic optic disc and optic cup semantic segmentation, but also the new model for possible glaucoma detection. The proposed method was trained on DRIVE and DIARETDB1 image datasets and evaluated on MESSIDOR dataset, where it achieved the average accuracy of 97.3% of optic disc and 88.1% of optic cup. Detection rate of glaucoma diesis is 96.75

    Automatic analysis of retinal images to aid in the diagnosis and grading of diabetic retinopathy

    Get PDF
    Diabetic retinopathy (DR) is the most common complication of diabetes mellitus and one of the leading causes of preventable blindness in the adult working population. Visual loss can be prevented from the early stages of DR, when the treatments are effective. Therefore, early diagnosis is paramount. However, DR may be clinically asymptomatic until the advanced stage, when vision is already affected and treatment may become difficult. For this reason, diabetic patients should undergo regular eye examinations through screening programs. Traditionally, DR screening programs are run by trained specialists through visual inspection of the retinal images. However, this manual analysis is time consuming and expensive. With the increasing incidence of diabetes and the limited number of clinicians and sanitary resources, the early detection of DR becomes non-viable. For this reason, computed-aided diagnosis (CAD) systems are required to assist specialists for a fast, reliable diagnosis, allowing to reduce the workload and the associated costs. We hypothesize that the application of novel, automatic algorithms for fundus image analysis could contribute to the early diagnosis of DR. Consequently, the main objective of the present Doctoral Thesis is to study, design and develop novel methods based on the automatic analysis of fundus images to aid in the screening, diagnosis, and treatment of DR. In order to achieve the main goal, we built a private database and used five retinal public databases: DRIMDB, DIARETDB1, DRIVE, Messidor and Kaggle. The stages of fundus image processing covered in this Thesis are: retinal image quality assessment (RIQA), the location of the optic disc (OD) and the fovea, the segmentation of RLs and EXs, and the DR severity grading. RIQA was studied with two different approaches. The first approach was based on the combination of novel, global features. Results achieved 91.46% accuracy, 92.04% sensitivity, and 87.92% specificity using the private database. We developed a second approach aimed at RIQA based on deep learning. We achieved 95.29% accuracy with the private database and 99.48% accuracy with the DRIMDB database. The location of the OD and the fovea was performed using a combination of saliency maps. The proposed methods were evaluated over the private database and the public databases DRIVE, DIARETDB1 and Messidor. For the OD, we achieved 100% accuracy for all databases except Messidor (99.50%). As for the fovea location, we also reached 100% accuracy for all databases except Messidor (99.67%). The joint segmentation of RLs and EXs was accomplished by decomposing the fundus image into layers. Results were computed per pixel and per image. Using the private database, 88.34% per-image accuracy (ACCi) was reached for the RL detection and 95.41% ACCi for EX detection. An additional method was proposed for the segmentation of RLs based on superpixels. Evaluating this method with the private database, we obtained 84.45% ACCi. Results were validated using the DIARETDB1 database. Finally, we proposed a deep learning framework for the automatic DR severity grading. The method was based on a novel attention mechanism which performs a separate attention of the dark and the bright structures of the retina. The Kaggle DR detection dataset was used for development and validation. The International Clinical DR Scale was considered, which is made up of 5 DR severity levels. Classification results for all classes achieved 83.70% accuracy and a Quadratic Weighted Kappa of 0.78. The methods proposed in this Doctoral Thesis form a complete, automatic DR screening system, contributing to aid in the early detection of DR. In this way, diabetic patients could receive better attention for their ocular health avoiding vision loss. In addition, the workload of specialists could be relieved while healthcare costs are reduced.La retinopatía diabética (RD) es la complicación más común de la diabetes mellitus y una de las principales causas de ceguera prevenible en la población activa adulta. El diagnóstico precoz es primordial para prevenir la pérdida visual. Sin embargo, la RD es clínicamente asintomática hasta etapas avanzadas, cuando la visión ya está afectada. Por eso, los pacientes diabéticos deben someterse a exámenes oftalmológicos periódicos a través de programas de cribado. Tradicionalmente, estos programas están a cargo de especialistas y se basan de la inspección visual de retinografías. Sin embargo, este análisis manual requiere mucho tiempo y es costoso. Con la creciente incidencia de la diabetes y la escasez de recursos sanitarios, la detección precoz de la RD se hace inviable. Por esta razón, se necesitan sistemas de diagnóstico asistido por ordenador (CAD) que ayuden a los especialistas a realizar un diagnóstico rápido y fiable, que permita reducir la carga de trabajo y los costes asociados. El objetivo principal de la presente Tesis Doctoral es estudiar, diseñar y desarrollar nuevos métodos basados en el análisis automático de retinografías para ayudar en el cribado, diagnóstico y tratamiento de la RD. Las etapas estudiadas fueron: la evaluación de la calidad de la imagen retiniana (RIQA), la localización del disco óptico (OD) y la fóvea, la segmentación de RL y EX y la graduación de la severidad de la RD. RIQA se estudió con dos enfoques diferentes. El primer enfoque se basó en la combinación de características globales. Los resultados lograron una precisión del 91,46% utilizando la base de datos privada. El segundo enfoque se basó en aprendizaje profundo. Logramos un 95,29% de precisión con la base de datos privada y un 99,48% con la base de datos DRIMDB. La localización del OD y la fóvea se realizó mediante una combinación de mapas de saliencia. Los métodos propuestos fueron evaluados sobre la base de datos privada y las bases de datos públicas DRIVE, DIARETDB1 y Messidor. Para el OD, logramos una precisión del 100% para todas las bases de datos excepto Messidor (99,50%). En cuanto a la ubicación de la fóvea, también alcanzamos un 100% de precisión para todas las bases de datos excepto Messidor (99,67%). La segmentación conjunta de RL y EX se logró descomponiendo la imagen del fondo de ojo en capas. Utilizando la base de datos privada, se alcanzó un 88,34% de precisión por imagen (ACCi) para la detección de RL y un 95,41% de ACCi para la detección de EX. Se propuso un método adicional para la segmentación de RL basado en superpíxeles. Evaluando este método con la base de datos privada, obtuvimos 84.45% ACCi. Los resultados se validaron utilizando la base de datos DIARETDB1. Finalmente, propusimos un método de aprendizaje profundo para la graduación automática de la gravedad de la DR. El método se basó en un mecanismo de atención. Se utilizó la base de datos Kaggle y la Escala Clínica Internacional de RD (5 niveles de severidad). Los resultados de clasificación para todas las clases alcanzaron una precisión del 83,70% y un Kappa ponderado cuadrático de 0,78. Los métodos propuestos en esta Tesis Doctoral forman un sistema completo y automático de cribado de RD, contribuyendo a ayudar en la detección precoz de la RD. De esta forma, los pacientes diabéticos podrían recibir una mejor atención para su salud ocular evitando la pérdida de visión. Además, se podría aliviar la carga de trabajo de los especialistas al mismo tiempo que se reducen los costes sanitarios.Escuela de DoctoradoDoctorado en Tecnologías de la Información y las Telecomunicacione

    A compactness based saliency approach for leakages detection in fluorescein angiogram

    Get PDF
    This study has developed a novel saliency detection method based on compactness feature for detecting three common types of leakage in retinal fluorescein angiogram: large focal, punctate focal, and vessel segment leakage. Leakage from retinal vessels occurs in a wide range of retinal diseases, such as diabetic maculopathy and paediatric malarial retinopathy. The proposed framework consists of three major steps: saliency detection, saliency refinement and leakage detection. First, the Retinex theory is adapted to address the illumination inhomogeneity problem. Then two saliency cues, intensity and compactness, are proposed for the estimation of the saliency map of each individual superpixel at each level. The saliency maps at different levels over the same cues are fused using an averaging operator. Finally, the leaking sites can be detected by masking the vessel and optic disc regions. The effectiveness of this framework has been evaluated by applying it to different types of leakage images with cerebral malaria. The sensitivity in detecting large focal, punctate focal and vessel segment leakage is 98.1, 88.2 and 82.7 %, respectively, when compared to a reference standard of manual annotations by expert human observers. The developed framework will become a new powerful tool for studying retinal conditions involving retinal leakage
    corecore