480 research outputs found

    Three-Dimensional Spectral-Domain Optical Coherence Tomography Data Analysis for Glaucoma Detection

    Get PDF
    Purpose: To develop a new three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) data analysis method using a machine learning technique based on variable-size super pixel segmentation that efficiently utilizes full 3D dataset to improve the discrimination between early glaucomatous and healthy eyes. Methods: 192 eyes of 96 subjects (44 healthy, 59 glaucoma suspect and 89 glaucomatous eyes) were scanned with SD-OCT. Each SD-OCT cube dataset was first converted into 2D feature map based on retinal nerve fiber layer (RNFL) segmentation and then divided into various number of super pixels. Unlike the conventional super pixel having a fixed number of points, this newly developed variable-size super pixel is defined as a cluster of homogeneous adjacent pixels with variable size, shape and number. Features of super pixel map were extracted and used as inputs to machine classifier (LogitBoost adaptive boosting) to automatically identify diseased eyes. For discriminating performance assessment, area under the curve (AUC) of the receiver operating characteristics of the machine classifier outputs were compared with the conventional circumpapillary RNFL (cpRNFL) thickness measurements. Results: The super pixel analysis showed statistically significantly higher AUC than the cpRNFL (0.855 vs. 0.707, respectively, p = 0.031, Jackknife test) when glaucoma suspects were discriminated from healthy, while no significant difference was found when confirmed glaucoma eyes were discriminated from healthy eyes. Conclusions: A novel 3D OCT analysis technique performed at least as well as the cpRNFL in glaucoma discrimination and even better at glaucoma suspect discrimination. This new method has the potential to improve early detection of glaucomatous damage. © 2013 Xu et al

    The automated detection of proliferative diabetic retinopathy using dual ensemble classification

    Get PDF
    Objective: Diabetic retinopathy (DR) is a retinal vascular disease that is caused by complications of diabetes. Proliferative diabetic retinopathy (PDR) is the advanced stage of the disease which carries a high risk of severe visual impairment. This stage is characterized by the growth of abnormal new vessels. We aim to develop a method for the automated detection of new vessels from retinal images. Methods: This method is based on a dual classification approach. Two vessel segmentation approaches are applied to create two separate binary vessel maps which each hold vital information. Local morphology, gradient and intensity features are measured using each binary vessel map to produce two separate 21-D feature vectors. Independent classification is performed for each feature vector using an ensemble system of bagged decision trees. These two independent outcomes are then combined to a produce a final decision. Results: Sensitivity and specificity results using a dataset of 60 images are 1.0000 and 0.9500 on a per image basis. Conclusions: The described automated system is capable of detecting the presence of new vessels

    Two-dimensional segmentation of the retinal vascular network from optical coherence tomography

    Get PDF
    The automatic segmentation of the retinal vascular network from ocular fundus images has been performed by several research groups. Although different approaches have been proposed for traditional imaging modalities, only a few have addressed this problem for optical coherence tomography (OCT). Furthermore, these approaches were focused on the optic nerve head region. Compared to color fundus photography and fluorescein angiography, two-dimensional ocular fundus reference images computed from three-dimensional OCT data present additional problems related to system lateral resolution, image contrast, and noise. Specifically, the combination of system lateral resolution and vessel diameter in the macular region renders the process particularly complex, which might partly explain the focus on the optic disc region. In this report, we describe a set of features computed from standard OCT data of the human macula that are used by a supervised-learning process (support vector machines) to automatically segment the vascular network. For a set of macular OCT scans of healthy subjects and diabetic patients, the proposed method achieves 98% accuracy, 99% specificity, and 83% sensitivity. This method was also tested on OCT data of the optic nerve head region achieving similar results

    Boosted learned kernels for data-driven vesselness measure

    Get PDF
    Common vessel centerline extraction methods rely on the computation of a measure providing the likeness of the local appearance of the data to a curvilinear tube-like structure. The most popular techniques rely on empirically designed (hand crafted) measurements as the widely used Hessian vesselness, the recent oriented flux tubeness or filters (e.g. the Gaussian matched filter) that are developed to respond to local features, without exploiting any context information nor the rich structural information embedded in the data. At variance with the previously proposed methods, we propose a completely data-driven approach for learning a vesselness measure from expert-annotated dataset. For each data point (voxel or pixel), we extract the intensity values in a neighborhood region, and estimate the discriminative convolutional kernel yielding a positive response for vessel data and negative response for non-vessel data. The process is iterated within a boosting framework, providing a set of linear filters, whose combined response is the learned vesselness measure. We show the results of the general-use proposed method on the DRIVE retinal images dataset, comparing its performance against the hessian-based vesselness, oriented flux antisymmetry tubeness, and vesselness learned with a probabilistic boosting tree or with a regression tree. We demonstrate the superiority of our approach that yields a vessel detection accuracy of 0.95, with respect to 0.92 (hessian), 0.90 (oriented flux) and 0.85 (boosting tree). © 2017 SPIE
    • …
    corecore