88 research outputs found

    Visual discomfort whilst viewing 3D stereoscopic stimuli

    Get PDF
    3D stereoscopic technology intensifies and heightens the viewer s experience by adding an extra dimension to the viewing of visual content. However, with expansion of this technology to the commercial market concerns have been expressed about the potential negative effects on the visual system, producing viewer discomfort. The visual stimulus provided by a 3D stereoscopic display differs from that of the real world, and so it is important to understand whether these differences may pose a health hazard. The aim of this thesis is to investigate the effect of 3D stereoscopic stimulation on visual discomfort. To that end, four experimental studies were conducted. In the first study two hypotheses were tested. The first hypothesis was that the viewing of 3D stereoscopic stimuli, which are located geometrically beyond the screen on which the images are displayed, would induce adaptation changes in the resting position of the eyes (exophoric heterophoria changes). The second hypothesis was that participants whose heterophoria changed as a consequence of adaptation during the viewing of the stereoscopic stimuli would experience less visual discomfort than those people whose heterophoria did not adapt. In the experiment an increase of visual discomfort change in the 3D condition in comparison with the 2D condition was found. Also, there were statistically significant changes in heterophoria under 3D conditions as compared with 2D conditions. However, there was appreciable variability in the magnitude of this adaptation among individuals, and no correlation between the amount of heterophoria change and visual discomfort change was observed. In the second experiment the two hypotheses tested were based on the vergence-accommodation mismatch theory, and the visual-vestibular mismatch theory. The vergence-accommodation mismatch theory predicts that a greater mismatch between the stimuli to accommodation and to vergence would produce greater symptoms in visual discomfort when viewing in 3D conditions than when viewing in 2D conditions. An increase of visual discomfort change in the 3D condition in comparison with the 2D condition was indeed found; however the magnitude of visual discomfort reported did not correlate with the mismatch present during the watching of 3D stereoscopic stimuli. The visual-vestibular mismatch theory predicts that viewing a stimulus stereoscopically will produce a greater sense of vection than viewing it in 2D. This will increase the conflict between the signals from the visual and vestibular systems, producing greater VIMS (Visually- Induced Motion Sickness) symptoms. Participants did indeed report an increase in motion sickness symptoms in the 3D condition. Furthermore, participants with closer seating positions reported more VIMS than participants sitting farther away whilst viewing 3D stimuli. This suggests that the amount of visual field stimulated during 3D presentation affects VIMS, and is an important factor in terms of viewing comfort. In the study more younger viewers (21 to 39 years old) than older viewers (40 years old and older) reported a greater change in visual discomfort during the 3D condition than the 2D condition. This suggests that the visual system s response to a stimulus, rather than the stimulus itself, is a reason for discomfort. No influence of gender on viewing comfort was found. In the next experiment participants fusion capability, as measured by their fusional reserves, was examined to determine whether this component has an impact on reported discomfort during the watching of movies in the 3D condition versus the 2D condition. It was hypothesised that participants with limited fusional range would experience more visual discomfort than participants with a wide fusion range. The hypothesis was confirmed but only in the case of convergent and not divergent eye movement. This observation illustrates that participants capability to convergence has a significant impact on visual comfort. The aim of the last experiment was to examine responses of the accommodation system to changes in 3D stimulus position and to determine whether discrepancies in these responses (i.e. accommodation overshoot, accommodation undershoot) could account for visual discomfort experienced during 3D stereoscopic viewing. It was found that accommodation discrepancy was larger for perceived forwards movement than for perceived backwards movement. The discrepancy was slightly higher in the group susceptible to visual discomfort than in the group not susceptible to visual discomfort, but this difference was not statistically significant. When considering the research findings as a whole it was apparent that not all participants experienced more discomfort whilst watching 3D stereoscopic stimuli than whilst watching 2D stimuli. More visual discomfort in the 3D condition than in the 2D condition was reported by 35% of the participants, whilst 24% of the participants reported more headaches and 17% of the participants reported more VIMS. The research indicates that multiple causative factors have an impact on reported symptoms. The analysis of the data suggests that discomfort experienced by people during 3D stereoscopic stimulation may reveal binocular vision problems. This observation suggests that 3D technology could be used as a screening method to diagnose un-treated binocular vision disorder. Additionally, this work shows that 3D stereoscopic technology can be easily adopted to binocular vision measurement. The conclusion of this thesis is that many people do not suffer adverse symptoms when viewing 3D stereoscopic displays, but that if adverse symptoms are present they can be caused either by the conflict in the stimulus, or by the heightened experience of self-motion which leads to Visually-Induced Motion Sickness (VIMS)

    Stereoscopic 3D Technologies for Accurate Depth Tasks: A Theoretical and Empirical Study

    Get PDF
    In the last decade an increasing number of application fields, including medicine, geoscience and bio-chemistry, have expressed a need to visualise and interact with data that are inherently three-dimensional. Stereoscopic 3D technologies can offer a valid support for these operations thanks to the enhanced depth representation they can provide. However, there is still little understanding of how such technologies can be used effectively to support the performance of visual tasks based on accurate depth judgements. Existing studies do not provide a sound and complete explanation of the impact of different visual and technical factors on depth perception in stereoscopic 3D environments. This thesis presents a new interpretative and contextualised analysis of the vision science literature to clarify the role of di®erent visual cues on human depth perception in such environments. The analysis identifies luminance contrast, spatial frequency, colour, blur, transparency and depth constancies as influential visual factors for depth perception and provides the theoretical foundation for guidelines to support the performance of accurate stereoscopic depth tasks. A novel assessment framework is proposed and used to conduct an empirical study to evaluate the performance of four distinct classes of 3D display technologies. The results suggest that 3D displays are not interchangeable and that the depth representation provided can vary even between displays belonging to the same class. The study also shows that interleaved displays may suffer from a number of aliasing artifacts, which in turn may affect the amount of perceived depth. The outcomes of the analysis of the influential visual factors for depth perception and the empirical comparartive study are used to propose a novel universal 3D cursor prototype suitable to support depth-based tasks in stereoscopic 3D environments. The contribution includes a number of both qualitative and quantitative guidelines that aim to guarantee a correct perception of depth in stereoscopic 3D environments and that should be observed when designing a stereoscopic 3D cursor

    Depth, shading, and stylization in stereoscopic cinematography

    Get PDF
    Due to the constantly increasing focus of the entertainment industry on stereoscopic imaging, techniques and tools that enable precise control over the depth impression and help to overcome limitations of the current stereoscopic hardware are gaining in importance. In this dissertation, we address selected problems encountered during stereoscopic content production, with a particular focus on stereoscopic cinema. First, we consider abrupt changes of depth, such as those induced by cuts in films. We derive a model predicting the time the visual system needs to adapt to such changes and propose how to employ this model for film cut optimization. Second, we tackle the issue of discrepancies between the two views of a stereoscopic image due to view-dependent shading of glossy materials. The suggested solution eliminates discomfort caused by non-matching specular highlights while preserving the perception of gloss. Last, we deal with the problem of filmgrainmanagement in stereoscopic productions and propose a new method for film grain application that reconciles visual comfort with the idea of medium-scene separation.Aufgrund der ständig steigenden Beachtung der stereoskopische Abbildung durch die Unterhaltungsindustrie, gewinnen Techniken und Werkzeuge an Bedeutung, die eine präzise Steuerung der Tiefenwahrnehmung ermöglichen und Einschränkungen der gegenwärtigen stereoskopischen Geräte überwinden. In dieser Dissertation adressieren wir ausgewählte Probleme, die während der Erzeugung von stereoskopischen Inhalten auftreten, mit besonderem Schwerpunkt auf der stereoskopischen Kinematographie. Zuerst betrachten wir abrupte Tiefenänderungen, wie sie durch Filmschnitte hervergerufen werden. Wir leiten ein Modell her, das die Zeit vorhersagt, die für das menschliche Sehsystem notwendig ist, um sich an solche Änderungen der Tiefe zu adaptieren, und schlagen vor wie dieses Modell für Schnittoptimierung angewendet werden kann. Danach gehen wir das Problem der Unstimmigkeiten zwischen den zwei Ansichten eines stereoskopischen Bildes, infolge der sichtabhängigen Schattierung von glänzenden Materialien, an. Die vorgeschlagene Lösung eliminiert das visuelle Unbehagen, welches von nicht zusammenpassenden Glanzlichtern verursacht wird, indessen bewahrt sie die Glanzwahrnehmung. Zuletzt behandeln wir das Problem des Filmkornsmanagements in stereoskopischen Produktionen und schlagen eine neue Methode für das Hinzufügen vom Filmkorn vor, die die visuelle Behaglichkeit mit der Idee der Medium-Szenen-Trennung in Einklang bringt

    Explaining Self-Motion Perception using Virtual Reality in Patients with Ocular Disease

    Full text link
    Safe mobility requires accurate object and self-motion perception. This involves processing retinal motion generated by optic flow (which change with eye and head movements) and correctly integrating this with vestibular and proprioceptive cues. Poor sensory feedback of self-motion can lead to increased risks of accidents which impacts quality of life. This is further problematic for those with visual deficits, such as central or peripheral vision loss or impaired binocular vision. The expansion of healthcare into using virtual reality (VR) has allowed the assessment of sensory and motor performance in a safe environment. An advantage of VR is its ability to generate vection (perceived illusory self-motion) and presence (sense of being ‘there’). However, a limitation is the potential to develop cybersickness. Initially, the project examined how binocular vision influences vection in a virtual environment. Observers with or without stereopsis (ability to judge depth binocularly) were asked to compare their perceptual experiences based on psychophysical judgements of magnitude estimation. The findings suggest that the absence of stereopsis impairs accurate judgement of self-motion and reduces perceived presence, however, it was protective for cybersickness. The project then examined the impact of central and peripheral vision loss on self-motion perception by comparing those with age-related macular degeneration (AMD) and glaucoma respectively. Effects of these visual deficits on sensory conflicts involving visual-vestibular interactions was then assessed. Sensory conflict was imposed by altering the gain of simulated head linear head position and angular orientation to be either compatible or incompatible with head movement in two separate experiments. Fixation was used to control gaze during changes in angular head orientation. Vection and presence was higher in those with AMD, compared with those with glaucoma, indicating the importance of regional specificity in visual deficits on self-motion perception. Across studies, vection and presence were predominantly visually mediated despite changes in visual-vestibular sensory conflict. The vestibular system, however, appeared to play a larger role in developing cybersickness. The altered perception of self-motion may worsen mobility, particularly with disease progression. We therefore provide a framework and recommendations for a multidisciplinary patient-centric model of care to maximise quality of life

    Binocular Interactions In The Human Visual Evoked Potential.

    Get PDF

    Stereoscopic high dynamic range imaging

    Get PDF
    Two modern technologies show promise to dramatically increase immersion in virtual environments. Stereoscopic imaging captures two images representing the views of both eyes and allows for better depth perception. High dynamic range (HDR) imaging accurately represents real world lighting as opposed to traditional low dynamic range (LDR) imaging. HDR provides a better contrast and more natural looking scenes. The combination of the two technologies in order to gain advantages of both has been, until now, mostly unexplored due to the current limitations in the imaging pipeline. This thesis reviews both fields, proposes stereoscopic high dynamic range (SHDR) imaging pipeline outlining the challenges that need to be resolved to enable SHDR and focuses on capture and compression aspects of that pipeline. The problems of capturing SHDR images that would potentially require two HDR cameras and introduce ghosting, are mitigated by capturing an HDR and LDR pair and using it to generate SHDR images. A detailed user study compared four different methods of generating SHDR images. Results demonstrated that one of the methods may produce images perceptually indistinguishable from the ground truth. Insights obtained while developing static image operators guided the design of SHDR video techniques. Three methods for generating SHDR video from an HDR-LDR video pair are proposed and compared to the ground truth SHDR videos. Results showed little overall error and identified a method with the least error. Once captured, SHDR content needs to be efficiently compressed. Five SHDR compression methods that are backward compatible are presented. The proposed methods can encode SHDR content to little more than that of a traditional single LDR image (18% larger for one method) and the backward compatibility property encourages early adoption of the format. The work presented in this thesis has introduced and advanced capture and compression methods for the adoption of SHDR imaging. In general, this research paves the way for a novel field of SHDR imaging which should lead to improved and more realistic representation of captured scenes

    Une méthode pour l'évaluation de la qualité des images 3D stéréoscopiques.

    Get PDF
    Dans le contexte d'un intérêt grandissant pour les systèmes stéréoscopiques, mais sans méthodes reproductible pour estimer leur qualité, notre travail propose une contribution à la meilleure compréhension des mécanismes de perception et de jugement humains relatifs au concept multi-dimensionnel de qualité d'image stéréoscopique. Dans cette optique, notre démarche s'est basée sur un certain nombre d'outils : nous avons proposé un cadre adapté afin de structurer le processus d'analyse de la qualité des images stéréoscopiques, nous avons implémenté dans notre laboratoire un système expérimental afin de conduire plusieurs tests, nous avons crée trois bases de données d'images stéréoscopiques contenant des configurations précises et enfin nous avons conduit plusieurs expériences basées sur ces collections d'images. La grande quantité d'information obtenue par l'intermédiaire de ces expérimentations a été utilisée afin de construire un premier modèle mathématique permettant d'expliquer la perception globale de la qualité de la stéréoscopie en fonction des paramètres physiques des images étudiée.In a context of ever-growing interest in stereoscopic systems, but where no standardized algorithmic methods of stereoscopic quality assessment exist, our work stands as a step forward in the understanding of the human perception and judgment mechanisms related to the multidimensional concept of stereoscopic image quality. We used a series of tools in order to perform in-depth investigations in this direction: we proposed an adapted framework to structure the process of stereoscopic quality assessment, we implemented a stereoscopic system in our laboratory for performing various tests, we created three stereoscopic datasets with precise structures, and we performed several experimental studies using these datasets. The numerous experimental data obtained were used in order to propose a first mathematical framework for explaining the overall percept of stereoscopic quality in function of the physical parameters of the stereoscopic images under study.SAVOIE-SCD - Bib.électronique (730659901) / SudocGRENOBLE1/INP-Bib.électronique (384210012) / SudocGRENOBLE2/3-Bib.électronique (384219901) / SudocSudocFranceF

    Ocular asymmetries and binocular vision

    Get PDF
    This study was undertaken to investigate ocular asymmetries in binocular vision using several dichoptic and binocular viewing paradigms. The literature on eye dominance was reviewed and it revealed that little emphasis both theoretically and experimentally had been placed on binocular viewing situations. The nature of the eye dominance tests and the dichotomous classification of the results suggested that one eye's image was competing against the other. The relationship between the different eye-dominance tests was not clear. A new approach to the study of ocular dominance has been developed in this thesis with specific attention to binocular vision and viewing situations. The term eye dominance has been replaced by the term ocular asymmetries to describe the results and measures derived from these procedures and the nature of the binocular visual approach. The experimental work is divided into three sections. Section one, is concerned with a binocular rivalry procedure using real images and afterimages. Section two, involves a stereoscopic viewing procedure and depth discrimination task with selective attenuation of the stereo-displays. Section three, investigates the interocular transfer of the spatial frequency shift. Measures of ocular asymmetry were derived, from all three procedures and the three sets of scores were positively related. This measure gives both the direction and the degree of the ocular asymmetry. The results indicate that ocular asymmetries are a valid feature of binocular vision. The new measure derived from the depth discrimination experiment provides a quantitative and consistent measure of ocular asymmetry. Special attention has been directed at the involvement of eye movements in all three paradigms and as the underlying factor in the asymmetry results. On the basis of the findings it was suggested that the asymmetry may reside in the binocular system controlling eye movements or reflect an asymmetry in processing speeds of the images from the two eyes arriving at the binocular site. The ocular asymmetry measures do not necessarily indicate eye movements are asymmetrical. It is recommended that ocular asymmetry is a variable to be studied in other investigations of binocular vision and binocular interactions
    • …
    corecore