4,011 research outputs found

    QT interval variability in body surface ECG: measurement, physiological basis, and clinical value: position statement and consensus guidance endorsed by the European Heart Rhythm Association jointly with the ESCWorking Group on Cardiac Cellular Electrophysiology

    Get PDF
    This consensus guideline discusses the electrocardiographic phenomenon of beat-to-beat QT interval variability (QTV) on surface electrocardiograms. The text covers measurement principles, physiological basis, and clinical value of QTV. Technical considerations include QT interval measurement and the relation between QTV and heart rate variability. Research frontiers of QTV include understanding of QTV physiology, systematic evaluation of the link between QTV and direct measures of neural activity, modelling of the QTV dependence on the variability of other physiological variables, distinction between QTV and general T wave shape variability, and assessing of the QTV utility for guiding therapy. Increased QTV appears to be a risk marker of arrhythmic and cardiovascular death. It remains to be established whether it can guide therapy alone or in combination with other risk factors. QT interval variability has a possible role in non-invasive assessment of tonic sympathetic activity

    QT variability calculation using a template matching algorithm and power spectral analysis

    Get PDF
    ECG interval measurement and variability analysis has proven to be a useful tool in investigating autonomic nervous system function. Traditionally, the R to R interval has been the thrust of research conducted in this field. QT variability is another topic on which little research has been done. This thesis uses an algorithm proposed by Dr. Berger, published in 2003. The algorithm stretches the template in the time domain, and composes a sum-squared error function, which is minimized to find the scaling factor for that beat. These scaling factors are compiled into an array, and an interpolated signal is generated of QT interval times. Using Lab VIEW and MATLAB, the algorithm was put into place, and frequency spectral analysis conducted on patients with normal sinus rhythm and those with arrhythmias. This system has been tested statistically, showing a less than 10 percent deviation from a standardized database of QT interval lengths (Physionet MIT/BIH databases) in all cases and less than 5 percent in most. In addition, power spectral analysis was conducted on patients with normal sinus rhythms and those with arrhythmias. However, major differences between patient populations were not observed with the performed techniques

    Diagnosis and treatment of atrial arrhythmias in horses

    Get PDF

    Realtime Multichannel System for Beat to Beat QT Interval Variability

    Get PDF
    The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results

    The 38th International Congress on Electrocardiology

    Get PDF

    Repolarization Changes Induced by Air Pollution in Ischemic Heart Disease Patients

    Get PDF
    Epidemiologic studies report associations between particulate air pollution and cardiovascular morbidity and mortality, but the underlying pathophysiologic mechanisms are still unclear. We tested the hypothesis that patients with preexisting coronary heart disease experience changes in the repolarization parameters in association with rising concentrations of air pollution. A prospective panel study was conducted in Erfurt, East Germany, with 12 repeated electrocardiogram (ECG) recordings in 56 males with ischemic heart disease. Hourly particulate and gaseous air pollution and meteorologic data were acquired. The following ECG parameters reflecting myocardial substrate and vulnerability were measured: QT duration, T-wave amplitude, T-wave complexity, and variability of T-wave complexity. Fixed effect regression analysis was used adjusting for subject, trend, weekday, and meteorology. The analysis showed a significant increase in QT duration in response to exposure to organic carbon; a significant decrease in T-wave amplitude with exposure to ultrafine, accumulation mode, and PM(2.5) particles (particles < 2.5 μm in aerodynamic diameter); and a corresponding significant increase of T-wave complexity in association with PM(2.5) particles for the 24 hr before ECG recordings. Variability of T-wave complexity showed a significant increase with organic and elemental carbon in the same time interval. This study provides evidence suggesting an immediate effect of air pollution on repolarization duration, morphology, and variability representing myocardial substrate and vulnerability, key factors in the mechanisms of cardiac death

    Diagnosing Long-QT Syndrome, Simple but not easy

    Get PDF

    High-Septal Pacing Reduces Ventricular Electrical Remodeling and Proarrhythmia in Chronic Atrioventricular Block Dogs

    Get PDF
    ObjectivesThis study was designed to analyze the relevance of ventricular activation patterns for ventricular electrical remodeling after atrioventricular (AV) block in dogs.BackgroundBradycardia is thought to be the main contributor to ventricular electrical remodeling after complete AV block. However, an altered ventricular activation pattern or AV dyssynchrony may also contribute.MethodsFor 4 weeks, AV block dogs were either paced from the high-ventricular septum near the His bundle at lowest captured rate (n = 9, high-septal pacing [HSP]) or kept at idioventricular rate without controlled activation (n = 14, chronic AV block [CAVB]). Multiple electrocardiographic and electrophysiological parameters were measured under anesthesia at 0 and 4 weeks. Proarrhythmia was tested at 4 weeks by IKrblock (25 μg/kg dofetilide intravenous).ResultsAt 0 weeks, the 2 groups were comparable, whereas after 4 weeks of similar bradycardia, QT duration at unpaced conditions had increased from 300 ± 5 to 395 ± 18 ms in CAVB (+32 ± 6%) and from 307 ± 8 ms to 357 ± 11 ms in HSP (+17 ± 4%; p < 0.05). Frequency dependency of repolarization was less steep in HSP compared to CAVB dogs after 4 weeks remodeling. Beat-to-beat variability of repolarization, a proarrhythmic parameter, increased only in CAVB from 0 to 4 weeks. Torsades de pointes arrhythmias were induced at 4 weeks in 44% HSP versus 78% CAVB dogs (p = 0.17). Cumulative duration of arrhythmias per inducible dog was 87 ± 36 s in CAVB and 30 ± 21 s in HSP (p < 0.05).ConclusionsHigh-septal pacing reduces the magnitude of ventricular electrical remodeling and proarrhythmia in AV block dogs, suggesting a larger role for altered ventricular activation pattern in the generation of ventricular electrical remodeling than previously assumed

    Estimation of potassium levels in hemodialysis patients by T wave nonlinear dynamics and morphology markers

    Get PDF
    Noninvasive screening of hypo- and hyperkalemia can prevent fatal arrhythmia in end-stage renal disease (ESRD) patients, but current methods for monitoring of serum potassium (K+) have important limitations. We investigated changes in nonlinear dynamics and morphology of the T wave in the electrocardiogram (ECG) of ESRD patients during hemodialysis (HD), assessing their relationship with K+ and designing a K+ estimator. Methods: ECG recordings from twenty-nine ESRD patients undergoing HD were processed. T waves in 2-min windows were extracted at each hour during an HD session as well as at 48 h after HD start. T wave nonlinear dynamics were characterized by two indices related to the maximum Lyapunov exponent (¿t, ¿wt) and a divergence-related index (¿). Morphological variability in the T wave was evaluated by three time warping-based indices (dw, reflecting morphological variability in the time domain, and da and daNL, in the amplitude domain). K+was measured from blood samples extracted during and after HD. Stage-specific and patient-specific K+ estimators were built based on the quantified indices and leave-one-out cross-validation was performed separately for each of the estimators. Results: The analyzed indices showed high inter-individual variability in their relationship with K+. Nevertheless, all of them had higher values at the HD start and 48 h after it, corresponding to the highest K+. The indices ¿ and dw were the most strongly correlated with K+ (median Pearson correlation coefficient of 0.78 and 0.83, respectively) and were used in univariable and multivariable linear K+ estimators. Agreement between actual and estimated K+ was confirmed, with averaged errors over patients and time points being 0.000 ± 0.875 mM and 0.046 ± 0.690 mM for stage-specific and patient-specific multivariable K+ estimators, respectively.ariability allow noninvasive monitoring of [K+] in ESRD patients. Significance: ECG markers have the potential to be used for hypo- and hyperkalemia screening in ESRD patient
    corecore