2,198 research outputs found
Vessel tractography using an intensity based tensor model with branch detection
In this paper, we present a tubular structure seg- mentation method that utilizes a second order tensor constructed from directional intensity measurements, which is inspired from diffusion tensor image (DTI) modeling. The constructed anisotropic tensor which is fit inside a vessel drives the segmen- tation analogously to a tractography approach in DTI. Our model is initialized at a single seed point and is capable of capturing whole vessel trees by an automatic branch detection algorithm developed in the same framework. The centerline of the vessel as well as its thickness is extracted. Performance results within the Rotterdam Coronary Artery Algorithm Evaluation framework are provided for comparison with existing techniques. 96.4% average overlap with ground truth delineated by experts is obtained in addition to other measures reported in the paper. Moreover, we demonstrate further quantitative results over synthetic vascular datasets, and we provide quantitative experiments for branch detection on patient Computed Tomography Angiography (CTA) volumes, as well as qualitative evaluations on the same CTA datasets, from visual scores by a cardiologist expert
Automated quantification and evaluation of motion artifact on coronary CT angiography images
Abstract Purpose
This study developed and validated a Motion Artifact Quantification algorithm to automatically quantify the severity of motion artifacts on coronary computed tomography angiography (CCTA) images. The algorithm was then used to develop a Motion IQ Decision method to automatically identify whether a CCTA dataset is of sufficient diagnostic image quality or requires further correction. Method
The developed Motion Artifact Quantification algorithm includes steps to identify the right coronary artery (RCA) regions of interest (ROIs), segment vessel and shading artifacts, and to calculate the motion artifact score (MAS) metric. The segmentation algorithms were verified against groundâtruth manual segmentations. The segmentation algorithms were also verified by comparing and analyzing the MAS calculated from groundâtruth segmentations and the algorithmâgenerated segmentations. The Motion IQ Decision algorithm first identifies slices with unsatisfactory image quality using a MAS threshold. The algorithm then uses an artifactâlength threshold to determine whether the degraded vessel segment is large enough to cause the dataset to be nondiagnostic. An observer study on 30 clinical CCTA datasets was performed to obtain the groundâtruth decisions of whether the datasets were of sufficient image quality. A fiveâfold crossâvalidation was used to identify the thresholds and to evaluate the Motion IQ Decision algorithm. Results
The automated segmentation algorithms in the Motion Artifact Quantification algorithm resulted in Dice coefficients of 0.84 for the segmented vessel regions and 0.75 for the segmented shading artifact regions. The MAS calculated using the automated algorithm was within 10% of the values obtained using groundâtruth segmentations. The MAS threshold and artifactâlength thresholds were determined by the ROC analysis to be 0.6 and 6.25 mm by all folds. The Motion IQ Decision algorithm demonstrated 100% sensitivity, 66.7% ± 27.9% specificity, and a total accuracy of 86.7% ± 12.5% for identifying datasets in which the RCA required correction. The Motion IQ Decision algorithm demonstrated 91.3% sensitivity, 71.4% specificity, and a total accuracy of 86.7% for identifying CCTA datasets that need correction for any of the three main vessels. Conclusion
The Motion Artifact Quantification algorithm calculated accurate
Vessel tractography using an intensity based tensor model
In this paper, we propose a novel tubular structure segmen- tation method, which is based on an intensity-based tensor that fits to a vessel. Our model is initialized with a single seed point and it is ca- pable of capturing whole vessel tree by an automatic branch detection algorithm. The centerline of the vessel as well as its thickness is extracted. We demonstrated the performance of our algorithm on 3 complex contrast varying tubular structured synthetic datasets for quantitative validation. Additionally, extracted arteries from 10 CTA (Computed Tomography An- giography) volumes are qualitatively evaluated by a cardiologist expertâs visual scores
Automatic segmentation of multiple cardiovascular structures from cardiac computed tomography angiography images using deep learning.
OBJECTIVES:To develop, demonstrate and evaluate an automated deep learning method for multiple cardiovascular structure segmentation. BACKGROUND:Segmentation of cardiovascular images is resource-intensive. We design an automated deep learning method for the segmentation of multiple structures from Coronary Computed Tomography Angiography (CCTA) images. METHODS:Images from a multicenter registry of patients that underwent clinically-indicated CCTA were used. The proximal ascending and descending aorta (PAA, DA), superior and inferior vena cavae (SVC, IVC), pulmonary artery (PA), coronary sinus (CS), right ventricular wall (RVW) and left atrial wall (LAW) were annotated as ground truth. The U-net-derived deep learning model was trained, validated and tested in a 70:20:10 split. RESULTS:The dataset comprised 206 patients, with 5.130 billion pixels. Mean age was 59.9 ± 9.4 yrs., and was 42.7% female. An overall median Dice score of 0.820 (0.782, 0.843) was achieved. Median Dice scores for PAA, DA, SVC, IVC, PA, CS, RVW and LAW were 0.969 (0.979, 0.988), 0.953 (0.955, 0.983), 0.937 (0.934, 0.965), 0.903 (0.897, 0.948), 0.775 (0.724, 0.925), 0.720 (0.642, 0.809), 0.685 (0.631, 0.761) and 0.625 (0.596, 0.749) respectively. Apart from the CS, there were no significant differences in performance between sexes or age groups. CONCLUSIONS:An automated deep learning model demonstrated segmentation of multiple cardiovascular structures from CCTA images with reasonable overall accuracy when evaluated on a pixel level
Joint segmentation and classification of retinal arteries/veins from fundus images
Objective Automatic artery/vein (A/V) segmentation from fundus images is
required to track blood vessel changes occurring with many pathologies
including retinopathy and cardiovascular pathologies. One of the clinical
measures that quantifies vessel changes is the arterio-venous ratio (AVR) which
represents the ratio between artery and vein diameters. This measure
significantly depends on the accuracy of vessel segmentation and classification
into arteries and veins. This paper proposes a fast, novel method for semantic
A/V segmentation combining deep learning and graph propagation.
Methods A convolutional neural network (CNN) is proposed to jointly segment
and classify vessels into arteries and veins. The initial CNN labeling is
propagated through a graph representation of the retinal vasculature, whose
nodes are defined as the vessel branches and edges are weighted by the cost of
linking pairs of branches. To efficiently propagate the labels, the graph is
simplified into its minimum spanning tree.
Results The method achieves an accuracy of 94.8% for vessels segmentation.
The A/V classification achieves a specificity of 92.9% with a sensitivity of
93.7% on the CT-DRIVE database compared to the state-of-the-art-specificity and
sensitivity, both of 91.7%.
Conclusion The results show that our method outperforms the leading previous
works on a public dataset for A/V classification and is by far the fastest.
Significance The proposed global AVR calculated on the whole fundus image
using our automatic A/V segmentation method can better track vessel changes
associated to diabetic retinopathy than the standard local AVR calculated only
around the optic disc.Comment: Preprint accepted in Artificial Intelligence in Medicin
Automation Process for Morphometric Analysis of Volumetric CT Data from Pulmonary Vasculature in Rats
With advances in medical imaging scanners, it has become commonplace to generate large multidimensional datasets. These datasets require tools for a rapid, thorough analysis. To address this need, we have developed an automated algorithm for morphometric analysis incorporating A Visualization Workshop computational and image processing libraries for three-dimensional segmentation, vascular tree generation and structural hierarchical ordering with a two-stage numeric optimization procedure for estimating vessel diameters. We combine this new technique with our mathematical models of pulmonary vascular morphology to quantify structural and functional attributes of lung arterial trees. Our physiological studies require repeated measurements of vascular structure to determine differences in vessel biomechanical properties between animal models of pulmonary disease. Automation provides many advantages including significantly improved speed and minimized operator interaction and biasing. The results are validated by comparison with previously published rat pulmonary arterial micro-CT data analysis techniques, in which vessels were manually mapped and measured using intense operator intervention
Coronary Artery Centerline Extraction in Cardiac CT Angiography Using a CNN-Based Orientation Classifier
Coronary artery centerline extraction in cardiac CT angiography (CCTA) images
is a prerequisite for evaluation of stenoses and atherosclerotic plaque. We
propose an algorithm that extracts coronary artery centerlines in CCTA using a
convolutional neural network (CNN).
A 3D dilated CNN is trained to predict the most likely direction and radius
of an artery at any given point in a CCTA image based on a local image patch.
Starting from a single seed point placed manually or automatically anywhere in
a coronary artery, a tracker follows the vessel centerline in two directions
using the predictions of the CNN. Tracking is terminated when no direction can
be identified with high certainty.
The CNN was trained using 32 manually annotated centerlines in a training set
consisting of 8 CCTA images provided in the MICCAI 2008 Coronary Artery
Tracking Challenge (CAT08). Evaluation using 24 test images of the CAT08
challenge showed that extracted centerlines had an average overlap of 93.7%
with 96 manually annotated reference centerlines. Extracted centerline points
were highly accurate, with an average distance of 0.21 mm to reference
centerline points. In a second test set consisting of 50 CCTA scans, 5,448
markers in the coronary arteries were used as seed points to extract single
centerlines. This showed strong correspondence between extracted centerlines
and manually placed markers. In a third test set containing 36 CCTA scans,
fully automatic seeding and centerline extraction led to extraction of on
average 92% of clinically relevant coronary artery segments.
The proposed method is able to accurately and efficiently determine the
direction and radius of coronary arteries. The method can be trained with
limited training data, and once trained allows fast automatic or interactive
extraction of coronary artery trees from CCTA images.Comment: Accepted in Medical Image Analysi
Automatic segmentation of coronary angiograms based on fuzzy inferring and probabilistic tracking
<p>Abstract</p> <p>Background</p> <p>Segmentation of the coronary angiogram is important in computer-assisted artery motion analysis or reconstruction of 3D vascular structures from a single-plan or biplane angiographic system. Developing fully automated and accurate vessel segmentation algorithms is highly challenging, especially when extracting vascular structures with large variations in image intensities and noise, as well as with variable cross-sections or vascular lesions.</p> <p>Methods</p> <p>This paper presents a novel tracking method for automatic segmentation of the coronary artery tree in X-ray angiographic images, based on probabilistic vessel tracking and fuzzy structure pattern inferring. The method is composed of two main steps: preprocessing and tracking. In preprocessing, multiscale Gabor filtering and Hessian matrix analysis were used to enhance and extract vessel features from the original angiographic image, leading to a vessel feature map as well as a vessel direction map. In tracking, a seed point was first automatically detected by analyzing the vessel feature map. Subsequently, two operators [e.g., a probabilistic tracking operator (PTO) and a vessel structure pattern detector (SPD)] worked together based on the detected seed point to extract vessel segments or branches one at a time. The local structure pattern was inferred by a multi-feature based fuzzy inferring function employed in the SPD. The identified structure pattern, such as crossing or bifurcation, was used to control the tracking process, for example, to keep tracking the current segment or start tracking a new one, depending on the detected pattern.</p> <p>Results</p> <p>By appropriate integration of these advanced preprocessing and tracking steps, our tracking algorithm is able to extract both vessel axis lines and edge points, as well as measure the arterial diameters in various complicated cases. For example, it can walk across gaps along the longitudinal vessel direction, manage varying vessel curvatures, and adapt to varying vessel widths in situations with arterial stenoses and aneurysms.</p> <p>Conclusions</p> <p>Our algorithm performs well in terms of robustness, automation, adaptability, and applicability. In particular, the successful development of two novel operators, namely, PTO and SPD, ensures the performance of our algorithm in vessel tracking.</p
- âŠ