    The MSFC vector magnetograph

    Get PDF
    The NASA/Marshall Space Flight Center's solar vector magnetograph system allows measurements of all components of the Sun's photospheric magnetic field over a 5 x 5 or 2.5 x 2.5 arc min square field of view with an optimum time resolution of approximately 100 sec and an optimum signal-to-noise of approximately 1000. The basic system components are described, including the optics, detector, digital system, and associated electronics. Automatic sequencing and control functions are outlined as well as manual selections of system parameters which afford unique system flexibility. Results of system calibration and performance are presented, including linearity, dynamic range, uniformity, spatial and spectral resolutions, signal-to-noise, electro-optical retardation and polarization calibration

    Analog sinewave signal generators for mixed-signal built-in test applications

    Get PDF
    This work presents a technique for the generation of analog sinusoidal signals with high spectral quality and reduced circuitry resources. Two integrated demonstrators are presented to show the feasibility of the approach. The proposed generation technique is based on a modified analog filter that provides a sinusoidal output as the response to a DC input. It has the attributes of digital programming and control, low area overhead, and low design effort, which make this approach very suitable as test stimulus generator for built-in test applications. The demonstrators—a continuous-time generator and a discrete-time one—have been integrated in a standard 0.35 μm CMOS technology. Simulation results and experimental measurements in the lab are provided, and the obtained performance is compared to current state-of-the-art on-chip generation strategies.Gobierno de España TEC2007-68072/MIC, TSI-020400-2008-71/MEDEA+2A105, CATRENE CT302Junta de Andalucía P09-TIC-538

    Development of microwave NDT inspection techniques for large solid propellant rocket motors Final report

    Get PDF
    Microwave nondestructive testing techniques for large solid propellant rocket engine

    A BIST solution for frequency domain characterization of analog circuits

    Get PDF
    This work presents an efficient implementation of a BIST solution for frequency characterization of analog systems. It allows a complete characterization in terms of magnitude and phase, including also harmonic distortion and offset measurements. Signal generation is performed using a modified filter, while response evaluation is based on 1storder ÓÄ modulation and very simple digital processing. The signal generator and the response analyzer have been implemented using the Switched-Capacitor (SC) technique in a standard 0.35ìm-3.3V CMOS technology. Both circuits have been separately validated, and an on-board prototype of the complete test system for frequency characterization has been implemented. Experimental results verify the functionality of the proposed approach, and a dynamic range of [email protected] (1MHz clock) has been demonstrated.Gobierno de España TEC2007-68072/MIC, TSI 020400- 2008-71Catrene European Project 2A105SR

    Analog-to-digital conversion techniques for precision photometry

    Get PDF
    Three types of analog-to-digital converters are described: parallel, successive-approximation, and integrating. The functioning of comparators and sample-and-hold amplifiers is explained. Differential and integral linearity are defined, and good and bad examples are illustrated. The applicability and relative advantages of the three types of converters for precision astronomical photometric measurements are discussed. For most measurements, integral linearity is more important than differential linearity. Successive-approximation converters should be used with multielement solid state detectors because of their high speed, but dual slope integrating converters may be superior for use with single element solid state detectors where speed of digitization is not a factor. In all cases, the input signal should be tailored so that they occupy the upper part of the converter's dynamic range; this can be achieved by providing adjustable gain, or better by varying the integration time of the observation if possible

    Index to 1981 NASA Tech Briefs, volume 6, numbers 1-4

    Get PDF
    Short announcements of new technology derived from the R&D activities of NASA are presented. These briefs emphasize information considered likely to be transferrable across industrial, regional, or disciplinary lines and are issued to encourage commercial application. This index for 1981 Tech Briefs contains abstracts and four indexes: subject, personal author, originating center, and Tech Brief Number. The following areas are covered: electronic components and circuits, electronic systems, physical sciences, materials, life sciences, mechanics, machinery, fabrication technology, and mathematics and information sciences

    Index to NASA Tech Briefs, 1975

    Get PDF
    This index contains abstracts and four indexes--subject, personal author, originating Center, and Tech Brief number--for 1975 Tech Briefs

    An embedded tester core for mixed-signal System-on-Chip circuits

    Get PDF

    The 30 GHz solid state amplifier for low cost low data rate ground terminals

    Get PDF
    This report details the development of a 20-W solid state amplifier operating near 30 GHz. The IMPATT amplifier not only met or exceeded all the program objectives, but also possesses the ability to operate in the pulse mode, which was not called for in the original contract requirements. The ability to operate in the pulse mode is essential for TDMA (Time Domain Multiple Access) operation. An output power of 20 W was achieved with a 1-dB instantaneous bandwidth of 260 MHz. The amplifier has also been tested in pulse mode with 50% duty for pulse lengths ranging from 200 ns to 2 micro s with 10 ns rise and fall times and no degradation in output power. This pulse mode operation was made possible by the development of a stable 12-diode power combiner/amplifier and a single-diode pulsed driver whose RF output power was switched on and off by having its bias current modulated via a fast-switching current pulse modulator. Essential to the overall amplifier development was the successful development of state-of-the-art silicon double-drift IMPATT diodes capable of reproducible 2.5 W CW output power with 12% dc-to-RF conversion efficiency. Output powers of as high as 2.75 W has been observed. Both the device and circuit design are amenable to low cost production

    Advanced measurement systems based on digital processing techniques for superconducting LHC magnets

    Get PDF
    The Large Hadron Collider (LHC), a particle accelerator aimed at exploring deeper into matter than ever before, is currently being constructed at CERN. Beam optics of the LHC, requires stringent control of the field quality of about 8400 superconducting magnets, including 1232 main dipoles and 360 main quadrupoles to assure the correct machine operation. The measurement challenges are various: accuracy on the field strength measurement up to 50 ppm, harmonics in the ppm range, measurement equipment robustness, low measurement times to characterize fast field phenomena. New magnetic measurement systems, principally based on analog solutions, have been developed at CERN to achieve these goals. This work proposes the introduction of digital technologies to improve measurement performance of three systems, aimed at different measurement target and characterized by different accuracy levels. The high accuracy measurement systems, based on rotating coils, exhibit high performance in static magnetic field. With varying magnetic field the system accuracy gets worse, independently from coil speed, due to the limited resolution of the digital integrator currently used, and the restrictions of the standard analysis. A new integrator based on ADC conversion and numerical integration is proposed. The experimental concept validation by emulating the proposed approach on a PXI platform is detailed along with the improvements with respect to the old integrators. Two new analysis algorithms to reduce the errors in dynamic measurements are presented. The first combines quadrature detection and short time Fourier transform (STFT) of the acquired magnetic flux samples; the second approach is based on the extrapolation of the magnetic flux samples. Unlike other algorithms presented in the literature, both the proposals do not require the information about the magnet current and are able to work in real time so, can be easily implemented in firmware on DSP. The performance of the new proposals are assessed in simulation. As far as medium accuracy systems are concerned, at CERN was originally developed a probe to measure the sextupolar and decapolar field harmonics of the superconducting dipoles using a suitable Hall plates arrangement for the bucking of the main dipolar field, which is, 4 orders of magnitude higher than the measurement target. The output signals of each Hall plate belonging to the same measurement ring are mixed using analog cards. The resultant signal is proportional to the field harmonic to measure. A complete metrological characterization of this sensor was carried out, showing the limitation of a fully analog solution. The main problems found were the instability of the analog compensation cards and the impossibility to correct the non linearity effects beyond the first order. An automatic calibration procedure implemented in the new instrument software is presented to guarantee measurement repeatability. In alternative a digital bucking solution, namely the compensation of the main field after the sampling of each hall plate signal by means of numerical sum, is proposed. An implementation of this approach, based on 18 bit ADC converter, over-sampling and dithering techniques as well as compensation of the Hall plates non linearity in real time is analyzed. Finally, as far as the low accuracy measurement systems are concerned, the design of an instrument based on a rotating Hall plate to check the polarity of all LHC magnets is presented. Even if this architecture is characterized by low accuracy in the measurement of field strength and phase, the results are sufficient to identify main harmonic order, type and polarity with practically no errors, thanks to an accurate definition of the measurement algorithm. A complete metrological characterization of the prototype developed and a correction of all the systematic measurement errors was carried out. This instrument, integrated in a test bench developed ad hoc, is become the standard at CERN for the polarity test of all the magnets will compose the machine
    corecore