1,053 research outputs found

    Automated Detection of External Ventricular and Lumbar Drain-Related Meningitis Using Laboratory and Microbiology Results and Medication Data

    Get PDF
    OBJECTIVE: Monitoring of healthcare-associated infection rates is important for infection control and hospital benchmarking. However, manual surveillance is time-consuming and susceptible to error. The aim was, therefore, to develop a prediction model to retrospectively detect drain-related meningitis (DRM), a frequently occurring nosocomial infection, using routinely collected data from a clinical data warehouse. METHODS: As part of the hospital infection control program, all patients receiving an external ventricular (EVD) or lumbar drain (ELD) (2004 to 2009; n = 742) had been evaluated for the development of DRM through chart review and standardized diagnostic criteria by infection control staff; this was the reference standard. Children, patients dying <24 hours after drain insertion or with <1 day follow-up and patients with infection at the time of insertion or multiple simultaneous drains were excluded. Logistic regression was used to develop a model predicting the occurrence of DRM. Missing data were imputed using multiple imputation. Bootstrapping was applied to increase generalizability. RESULTS: 537 patients remained after application of exclusion criteria, of which 82 developed DRM (13.5/1000 days at risk). The automated model to detect DRM included the number of drains placed, drain type, blood leukocyte count, C-reactive protein, cerebrospinal fluid leukocyte count and culture result, number of antibiotics started during admission, and empiric antibiotic therapy. Discriminatory power of this model was excellent (area under the ROC curve 0.97). The model achieved 98.8% sensitivity (95% CI 88.0% to 99.9%) and specificity of 87.9% (84.6% to 90.8%). Positive and negative predictive values were 56.9% (50.8% to 67.9%) and 99.9% (98.6% to 99.9%), respectively. Predicted yearly infection rates concurred with observed infection rates. CONCLUSION: A prediction model based on multi-source data stored in a clinical data warehouse could accurately quantify rates of DRM. Automated detection using this statistical approach is feasible and could be applied to other nosocomial infections

    Information technology aspects of large-scale implementation of automated surveillance of healthcare-associated infections

    Get PDF
    PRAISE network: Maaike S. M. van Mourik, Stephanie M.van Rooden, Mohamed Abbas, Olov Aspevall, Pascal Astagneau, Marc J. M. Bonten, Elena Carrara, Aina Gomila-Grange, Sabine C. de Greeff , Sophie Gubbels, Wendy Harrison, Hilary Humphreys, Anders Johansson, Mayke B. G. Koek, Brian Kristensen, Alain Lepape, Jean-Christophe Lucet, Siddharth Mookerjee, Pontus Naucler, Zaira R. Palacios-Baena, Elisabeth Presterl, Miquel Pujol, Jacqui Reilly, Christopher Roberts, Evelina Tacconelli, Daniel Teixeira, Thomas Tängdén, John Karlsson Valik, Michael Behnke, PetraGastmeier.[Introduction] Healthcare-associated infections (HAI) are a major public health concern. Monitoring of HAI rates, with feedback, is a core component of infection prevention and control programmes. Digitalization of healthcare data has created novel opportunities for automating the HAI surveillance process to varying degrees. However, methods are not standardized and vary widely between different healthcare facilities. Most current automated surveillance (AS) systems have been confined to local settings, and practical guidance on how to implement large-scale AS is needed.[Methods] This document was written by a task force formed in March 2019 within the PRAISE network (Providing a Roadmap for Automated Infection Surveillance in Europe), gathering experts in HAI surveillance from ten European countries.[Results] The document provides an overview of the key e-health aspects of implementing an AS system of HAI in a clinical environment to support both the infection prevention and control team and information technology (IT) departments. The focus is on understanding the basic principles of storage and structure of healthcare data, as well as the general organization of IT infrastructure in surveillance networks and participating healthcare facilities. The fundamentals of data standardization, interoperability and algorithms in relation to HAI surveillance are covered. Finally, technical aspects and practical examples of accessing, storing and sharing healthcare data within a HAI surveillance network, as well as maintenance and quality control of such a system, are discussed.[Conclusions] With the guidance given in this document, along with the PRAISE roadmap and governance documents, readers will find comprehensive support to implement large-scale AS in a surveillance network.This network has been supported under the 7th transnational call within the Joint Programming Initiative on Antimicrobial Resistance (JPIAMR), Network Call on Surveillance (2018) and was thereby funded by ZonMw (grant 549007001). This project also received support from the COMBACTE MAGNET EPI-Net project funded by the Innovative Medicines Initiative Joint Undertaking under grant agreement 115523 | 115620 | 115737 | 777362, resources of which are composed of financial contribution from the European Union Seventh Framework Programme (FP7/2007-2013) and EFPIA companies in kind contribution. J.K.V. was supported by grants from Region Stockholm and Vinnova.Peer reviewe

    A Fuzzy Inference System for the Assessment of Indoor Air Quality in an Operating Room to Prevent Surgical Site Infection

    Get PDF
    Indoor air quality in hospital operating rooms is of great concern for the prevention of surgical site infections (SSI). A wide range of relevant medical and engineering literature has shown that the reduction in air contamination can be achieved by introducing a more efficient set of controls of HVAC systems and exploiting alarms and monitoring systems that allow having a clear report of the internal air status level. In this paper, an operating room air quality monitoring system based on a fuzzy decision support system has been proposed in order to help hospital staff responsible to guarantee a safe environment. The goal of the work is to reduce the airborne contamination in order to optimize the surgical environment, thus preventing the occurrence of SSI and reducing the related mortality rate. The advantage of FIS is that the evaluation of the air quality is based on easy-to-find input data established on the best combination of parameters and level of alert. Compared to other literature works, the proposed approach based on the FIS has been designed to take into account also the movement of clinicians in the operating room in order to monitor unauthorized paths. The test of the proposed strategy has been executed by exploiting data collected by ad-hoc sensors placed inside a real operating block during the experimental activities of the “Bacterial Infections Post Surgery” Project (BIPS). Results show that the system is capable to return risk values with extreme precision

    Electronically assisted surveillance systems of healthcare-associated infections:a systematic review

    Get PDF
    Background: Surveillance of healthcare-associated infections (HAI) is the basis of each infection control programme and, in case of acute care hospitals, should ideally include all hospital wards, medical specialties as well as all types of HAI. Traditional surveillance is labour intensive and electronically assisted surveillance systems (EASS) hold the promise to increase efficiency. Objectives: To give insight in the performance characteristics of different approaches to EASS and the quality of the studies designed to evaluate them. Methods: In this systematic review, online databases were searched and studies that compared an EASS with a traditional surveillance method were included. Two different indicators were extracted from each study, one regarding the quality of design (including reporting efficiency) and one based on the performance (e.g. specificity and sensitivity) of the EASS presented. Results: A total of 78 studies were included. The majority of EASS (n = 72) consisted of an algorithm-based selection step followed by confirmatory assessment. The algorithms used different sets of variables. Only a minority (n = 7) of EASS were hospital- wide and designed to detect all types of HAI. Sensitivity of EASS was generally high (> 0.8), but specificity varied (0.37-1). Less than 20% (n = 14) of the studies presented data on the efficiency gains achieved. Conclusions: Electronically assisted surveillance of HAI has yet to reach a mature stage and to be used routinely in healthcare settings. We recommend that future studies on the development and implementation of EASS of HAI focus on thorough validation, reproducibility, standardised datasets and detailed information on efficiency

    Electronically assisted surveillance systems of healthcare-associated infections: A systematic review

    Get PDF
    Background: Surveillance of healthcare-associated infections (HAI) is the basis of each infection control programme and, in case of acute care hospitals, should ideally include all hospital wards, medical specialties as well as all types of HAI. Traditional surveillance is labour intensive and electronically assisted surveillance systems (EASS) hold the promise to increase efficiency. Objectives: To give insight in the performance characteristics of different approaches to EASS and the quality of the studies designed to evaluate them. Methods: In this systematic review, online databases were searched and studies that compared an EASS with a traditional surveillance method were included. Two different indicators were extracted from each study, one regarding the quality of design (including reporting efficiency) and one based on the performance (e.g. specificity and sensitivity) of the EASS presented. Results: A total of 78 studies were included. The majority of EASS (n = 72) consisted of an algorithm-based selection step followed by confirmatory assessment. The algorithms used different sets of variables. Only a minority (n = 7) of EASS were hospital-wide and designed to detect all types of HAI. Sensitivity of EASS was generally high (> 0.8), but specificity varied (0.37 1). Less than 20% (n = 14) of the studies presented data on the efficiency gains achieved. Conclusions: Electronically assisted surveillance of HAI has yet to reach a mature stage and to be used routinely in healthcare settings. We recommend that future studies on the development and implementation of EASS of HAI focus on thorough validation, reproducibility, standardised datasets and detailed information on efficiency

    Electronically assisted surveillance systems of healthcare-associated infections: a systematic review

    Get PDF
    BackgroundSurveillance of healthcare-associated infections (HAI) is the basis of each infection control programme and, in case of acute care hospitals, should ideally include all hospital wards, medical specialties as well as all types of HAI. Traditional surveillance is labour intensive and electronically assisted surveillance systems (EASS) hold the promise to increase efficiency.ObjectivesTo give insight in the performance characteristics of different approaches to EASS and the quality of the studies designed to evaluate them.MethodsIn this systematic review, online databases were searched and studies that compared an EASS with a traditional surveillance method were included. Two different indicators were extracted from each study, one regarding the quality of design (including reporting efficiency) and one based on the performance (e.g. specificity and sensitivity) of the EASS presented.ResultsA total of 78 studies were included. The majority of EASS (n = 72) consisted of an algorithm-based selection step followed by confirmatory assessment. The algorithms used different sets of variables. Only a minority (n = 7) of EASS were hospital-wide and designed to detect all types of HAI. Sensitivity of EASS was generally high (> 0.8), but specificity varied (0.37-1). Less than 20% (n = 14) of the studies presented data on the efficiency gains achieved.ConclusionsElectronically assisted surveillance of HAI has yet to reach a mature stage and to be used routinely in healthcare settings. We recommend that future studies on the development and implementation of EASS of HAI focus on thorough validation, reproducibility, standardised datasets and detailed information on efficiency

    Comparison of Automated Strategies for Surveillance of Nosocomial Bacteremia

    Get PDF
    Objective. Surveillance of nosocomial bloodstream infection (BSI) is recommended, but time-consuming. We explored strategies for automated surveillance. Methods. Cohort study. We prospectively processed microbiological and administrative patient data with computerized algorithms to identify contaminated blood cultures, community-acquired BSI, and hospital-acquired BSI and used algorithms to classify the latter on the basis of whether it was a catheter-associated infection. We compared the automatic classification with an assessment (71% prospective) of clinical data. Setting. An 850-bed university hospital. Participants. All adult patients admitted to general surgery, internal medicine, a medical intensive care unit, or a surgical intensive care unit over 3 years. Results. The results of the automated surveillance were 95% concordant with those of classical surveillance based on the assessment of clinical data in distinguishing contamination, community-acquired BSI, and hospital-acquired BSI in a random sample of 100 cases of bacteremia. The two methods were 74% concordant in classifying 351 consecutive episodes of nosocomial BSI with respect to whether the BSI was catheter-associated. Prolonged episodes of BSI, mostly fungemia, that were counted multiple times and incorrect classification of BSI clinically imputable to catheter infection accounted for 81% of the misclassifications in automated surveillance. By counting episodes of fungemia only once per hospital stay and by considering all cases of coagulase-negative staphylococcal BSI to be catheter-related, we improved concordance with clinical assessment to 82%. With these adjustments, automated surveillance for detection of catheter-related BSI had a sensitivity of 78% and a specificity of 93%; for detection of other types of nosocomial BSI, the sensitivity was 98% and the specificity was 69%. Conclusion. Automated strategies are convenient alternatives to manual surveillance of nosocomial BS

    Managing Quality in Health Care

    Get PDF
    • …
    corecore