7,437 research outputs found

    Automated detection of epileptic ripples in MEG using beamformer-based virtual sensors

    Get PDF
    Objective. In epilepsy, high-frequency oscillations (HFOs) are expressively linked to the seizure onset zone (SOZ). The detection of HFOs in the noninvasive signals from scalp electroencephalography (EEG) and magnetoencephalography (MEG) is still a challenging task. The aim of this study was to automate the detection of ripples in MEG signals by reducing the high-frequency noise using beamformer-based virtual sensors (VSs) and applying an automatic procedure for exploring the time-frequency content of the detected events. Approach. Two-hundred seconds of MEG signal and simultaneous iEEG were selected from nine patients with refractory epilepsy. A two-stage algorithm was implemented. Firstly, beamforming was applied to the whole head to delimitate the region of interest (ROI) within a coarse grid of MEG-VS. Secondly, a beamformer using a finer grid in the ROI was computed. The automatic detection of ripples was performed using the time-frequency response provided by the Stockwell transform. Performance was evaluated through comparisons with simultaneous iEEG signals. Main results. ROIs were located within the seizure-generating lobes in the nine subjects. Precision and sensitivity values were 79.18% and 68.88%, respectively, by considering iEEG-detected events as benchmarks. A higher number of ripples were detected inside the ROI compared to the same region in the contralateral lobe. Significance. The evaluation of interictal ripples using non-invasive techniques can help in the delimitation of the epileptogenic zone and guide placement of intracranial electrodes. This is the first study that automatically detects ripples in MEG in the time domain located within the clinically expected epileptic area taking into account the time-frequency characteristics of the events through the whole signal spectrum. The algorithm was tested against intracranial recordings, the current gold standard. Further studies should explore this approach to enable the localization of noninvasively recorded HFOs to help during pre-surgical planning and to reduce the need for invasive diagnostics.Peer ReviewedPostprint (author's final draft

    Detection and Magnetic Source Imaging of Fast Oscillations (40–160 Hz) Recorded with Magnetoencephalography in Focal Epilepsy Patients

    Get PDF
    We present a framework to detect fast oscillations (FOs) in magnetoencephalography (MEG) and to perform magnetic source imaging (MSI) to determine the location and extent of their generators in the cortex. FOs can be of physiologic origin associated to sensory processing and memory consolidation. In epilepsy, FOs are of pathologic origin and biomarkers of the epileptogenic zone. Seventeen patients with focal epilepsy previously confirmed with identified FOs in scalp electroencephalography (EEG) were evaluated. To handle data deriving from large number of sensors (275 axial gradiometers) we used an automatic detector with high sensitivity. False positives were discarded by two human experts. MSI of the FOs was performed with the wavelet based maximum entropy on the mean method. We found FOs in 11/17 patients, in only one patient the channel with highest FO rate was not concordant with the epileptogenic region and might correspond to physiologic oscillations. MEG FOs rates were very low: 0.02–4.55 per minute. Compared to scalp EEG, detection sensitivity was lower, but the specificity higher in MEG. MSI of FOs showed concordance or partial concordance with proven generators of seizures and epileptiform activity in 10/11 patients. We have validated the proposed framework for the non-invasive study of FOs with MEG. The excellent overall concordance with other clinical gold standard evaluation tools indicates that MEG FOs can provide relevant information to guide implantation for intracranial EEG pre-surgical evaluation and for surgical treatment, and demonstrates the important added value of choosing appropriate FOs detection and source localization methods.Facultad de IngenieríaInstituto de Investigaciones en Electrónica, Control y Procesamiento de Señale

    Automatic detection and visualisation of MEG ripple oscillations in epilepsy

    Get PDF
    High frequency oscillations (HFOs, 80–500 Hz) in invasive EEG are a biomarker for the epileptic focus. Ripples (80–250 Hz) have also been identified in non-invasive MEG, yet detection is impeded by noise, their low occurrence rates, and the workload of visual analysis. We propose a method that identifies ripples in MEG through noise reduction, beamforming and automatic detection with minimal user effort. We analysed 15 min of presurgical resting-state interictal MEG data of 25 patients with epilepsy. The MEG signal-to-noise was improved by using a cross-validation signal space separation method, and by calculating ~ 2400 beamformer-based virtual sensors in the grey matter. Ripples in these sensors were automatically detected by an algorithm optimized for MEG. A small subset of the identified ripples was visually checked. Ripple locations were compared with MEG spike dipole locations and the resection area if available. Running the automatic detection algorithm resulted in on average 905 ripples per patient, of which on average 148 ripples were visually reviewed. Reviewing took approximately 5 min per patient, and identified ripples in 16 out of 25 patients. In 14 patients the ripple locations showed good or moderate concordance with the MEG spikes. For six out of eight patients who had surgery, the ripple locations showed concordance with the resection area: 4/5 with good outcome and 2/3 with poor outcome. Automatic ripple detection in beamformer-based virtual sensors is a feasible non-invasive tool for the identification of ripples in MEG. Our method requires minimal user effort and is easily applicable in a clinical setting

    SGM: a novel time-frequency algorithm based on unsupervised learning improves high-frequency oscillation detection in epilepsy

    Get PDF
    Objective. We propose a novel automated method called the S-Transform Gaussian Mixture detection algorithm (SGM) to detect high-frequency oscillations (HFO) combining the strengths of different families of previously published detectors. Approach. This algorithm does not depend on parameter tuning on a subject (or database) basis, uses time-frequency characteristics, and relies on non-supervised classification to determine if the events standing out from the baseline activity are HFO or not. SGM consists of three steps: the first stage computes the signal baseline using the entropy of the autocorrelation; the second uses the S-Transform to obtain several time-frequency features (area, entropy, and time and frequency widths); and in the third stage Gaussian mixture models cluster time-frequency features to decide if events correspond to HFO-like activity. To validate the SGM algorithm we tested its performance in simulated and real environments. Main results. We assessed the algorithm on a publicly available simulated stereoelectroencephalographic (SEEG) database with varying signal-to-noise ratios (SNR), obtaining very good results for medium and high SNR signals. We further tested the SGM algorithm on real signals from patients with focal epilepsy, in which HFO detection was performed visually by experts, yielding a high agreement between experts and SGM. Significance. The SGM algorithm displayed proper performance in simulated and real environments and therefore can be used for non-supervised detection of HFO. This non-supervised algorithm does not require previous labelling by experts or parameter adjustment depending on the subject or database considered. SGM is not a computationally intensive algorithm, making it suitable to detect and characterize HFO in long-term SEEG recordings.Peer ReviewedPostprint (published version

    Analytical methods and experimental approaches for electrophysiological studies of brain oscillations

    Get PDF
    Brain oscillations are increasingly the subject of electrophysiological studies probing their role in the functioning and dysfunction of the human brain. In recent years this research area has seen rapid and significant changes in the experimental approaches and analysis methods. This article reviews these developments and provides a structured overview of experimental approaches, spectral analysis techniques and methods to establish relationships between brain oscillations and behaviour

    Detection of pathological high-frequency oscillations in refractory epilepsy patients undergoing simultaneous stereo-electroencephalography and magnetoencephalography

    Get PDF
    BACKGROUND: Stereo-electroencephalography (SEEG) and magnetoencephalography (MEG) have generally been used independently as part of the pre-surgical evaluation of drug-resistant epilepsy (DRE) patients. However, the possibility of simultaneously employing these recording techniques to determine whether MEG has the potential of offering the same information as SEEG less invasively, or whether it could offer a greater spatial indication of the epileptogenic zone (EZ) to aid surgical planning, has not been previously evaluated. METHODS: Data from 24 paediatric and adult DRE patients, undergoing simultaneous SEEG and MEG as part of their pre-surgical evaluation, was analysed employing manual and automated high-frequency oscillations (HFOs) detection, and spectral and source localisation analyses. RESULTS: Twelve patients (50%) were included in the analysis (4 males; mean age=25.08 years) and showed interictal SEEG and MEG HFOs. HFOs detection was concordant between the two recording modalities, but SEEG displayed higher ability of differentiating between deep and superficial epileptogenic sources. Automated HFO detector in MEG recordings was validated against the manual MEG detection method. Spectral analysis revealed that SEEG and MEG detect distinct epileptic events. The EZ was well correlated with the simultaneously recorded data in 50% patients, while 25% patients displayed poor correlation or discordance. CONCLUSIONS: MEG recordings can detect HFOs, and simultaneous use of SEEG and MEG HFO identification facilitates EZ localisation during the presurgical planning stage for DRE patients. Further studies are necessary to validate these findings and support the translation of automated HFO detectors into routine clinical practice
    corecore