155 research outputs found

    Imaging of Osteoarthritis and Rheumatoid Arthritis in Hand Joints

    Get PDF

    Deep learning-based fully automatic segmentation of wrist cartilage in MR images

    Full text link
    The study objective was to investigate the performance of a dedicated convolutional neural network (CNN) optimized for wrist cartilage segmentation from 2D MR images. CNN utilized a planar architecture and patch-based (PB) training approach that ensured optimal performance in the presence of a limited amount of training data. The CNN was trained and validated in twenty multi-slice MRI datasets acquired with two different coils in eleven subjects (healthy volunteers and patients). The validation included a comparison with the alternative state-of-the-art CNN methods for the segmentation of joints from MR images and the ground-truth manual segmentation. When trained on the limited training data, the CNN outperformed significantly image-based and patch-based U-Net networks. Our PB-CNN also demonstrated a good agreement with manual segmentation (Sorensen-Dice similarity coefficient (DSC) = 0.81) in the representative (central coronal) slices with large amount of cartilage tissue. Reduced performance of the network for slices with a very limited amount of cartilage tissue suggests the need for fully 3D convolutional networks to provide uniform performance across the joint. The study also assessed inter- and intra-observer variability of the manual wrist cartilage segmentation (DSC=0.78-0.88 and 0.9, respectively). The proposed deep-learning-based segmentation of the wrist cartilage from MRI could facilitate research of novel imaging markers of wrist osteoarthritis to characterize its progression and response to therapy

    Imaging of Osteoarthritis and Rheumatoid Arthritis in Hand Joints

    Get PDF

    DeepRA: Predicting Joint Damage From Radiographs Using CNN with Attention

    Full text link
    Joint damage in Rheumatoid Arthritis (RA) is assessed by manually inspecting and grading radiographs of hands and feet. This is a tedious task which requires trained experts whose subjective assessment leads to low inter-rater agreement. An algorithm which can automatically predict the joint level damage in hands and feet can help optimize this process, which will eventually aid the doctors in better patient care and research. In this paper, we propose a two-staged approach which amalgamates object detection and convolution neural networks with attention which can efficiently and accurately predict the overall and joint level narrowing and erosion from patients radiographs. This approach has been evaluated on hands and feet radiographs of patients suffering from RA and has achieved a weighted root mean squared error (RMSE) of 1.358 and 1.404 in predicting joint level narrowing and erosion Sharp van der Heijde (SvH) scores which is 31% and 19% improvement with respect to the baseline SvH scores, respectively. The proposed approach achieved a weighted absolute error of 1.456 in predicting the overall damage in hands and feet radiographs for the patients which is a 79% improvement as compared to the baseline. Our method also provides an inherent capability to provide explanations for model predictions using attention weights, which is essential given the black box nature of deep learning models. The proposed approach was developed during the RA2 Dream Challenge hosted by Dream Challenges and secured 4th and 8th position in predicting overall and joint level narrowing and erosion SvH scores from radiographs

    Segmentation of bones in magnetic resonance images of the wrist

    Get PDF
    PURPOSE:   Rheumatoid arthritis (RA) is a disease characterized by progressive and irreversible destruction of bones and joints. According to current recommendations, magnetic resonance imaging (MRI) is used to asses three main signs of RA based on manual evaluation of MR images: synovitis, bone edema and bone erosions. The key feature of a future computer-assisted diagnostic system for evaluation RA lesions is accurate segmentation of 15 wrist bones. In the present paper, we focus on developing a wrist bones segmentation framework. METHOD:    The segmentation procedure consisted of three stages: segmentation of the distal parts of ulna and radius, segmentation of the proximal parts of metacarpal bones and segmentation of carpal bones. At every stage, markers of bones were determined first, using an atlas-based approach. Then, given markers of bones and a marker of background, a watershed from markers algorithm was applied to find the final segmentation. RESULTS:   The MR data for 37 cases were analyzed. The automated segmentation results were compared with gold-standard manual segmentations using a few well-established metrics: area under ROC curve AUC, mean similarity MS and mean absolute distance MAD. The mean (standard deviation) values of AUC, MS and MAD were 0.97 (0.04), 0.93 (0.09) and 1.23 (0.28), respectively. CONCLUSION:   The results of the present study demonstrate that automated segmentation of wrist bones is feasible. The proposed algorithm can be the first stage for the detection of early lesions like bone edema or synovitis

    Automatic radiographic quantification of hand osteoarthritis; accuracy and sensitivity to change in joint space width in a phantom and cadaver study

    Get PDF
    This is the final version of the article. Available from Springer Verlag via the DOI in this record.OBJECTIVE: To validate a newly developed quantification method that automatically detects and quantifies the joint space width (JSW) in hand radiographs. Repeatability, accuracy and sensitivity to changes in JSW were determined. The influence of joint location and joint shape on the measurements was tested. METHODS: A mechanical micrometer set-up was developed to define and adjust the true JSW in an acrylic phantom joint and in human cadaver-derived phalangeal joints. Radiographic measurements of the JSW were compared to the true JSW. Repeatability, systematic error (accuracy) and sensitivity (defined as the smallest detectable difference (SDD)) were determined. The influence of joint position on the JSW measurement was assessed by varying the location of the acrylic phantom on the X-ray detector with respect to the X-ray beam and the influence of joint shape was determined by using morphologically different human cadaver joints. RESULTS: The mean systematic error was 0.052 mm in the phantom joint and 0.210 mm in the cadaver experiment. In the phantom experiments, the repeatability was high (SDD = 0.028 mm), but differed slightly between joint locations (p = 0.046), and a change in JSW of 0.037 mm could be detected. Dependent of the joint shape in the cadaver hand, a change in JSW between 0.018 and 0.047 mm could be detected. CONCLUSIONS: The automatic quantification method is sensitive to small changes in JSW. Considering the published data of JSW decline in the normal and osteoarthritic population, the first signs of OA progression with this method can be detected within 1 or 2 years.This work was funded by the Dutch Arthritis Association (Reumafonds). The study sponsor had no involvement in study design, data collection, data analysis, or interpretation of the results
    • …
    corecore