Deep learning for image-based liver analysis — A comprehensive review focusing on malignant lesions
Deep learning-based methods, in particular, convolutional neural networks and fully convolutional networks are now widely used in the medical image analysis domain. The scope of this review focuses on the analysis using deep learning of focal liver lesions, with a special interest in hepatocellular carcinoma and metastatic cancer; and structures like the parenchyma or the vascular system. Here, we address several neural network architectures used for analyzing the anatomical structures and lesions in the liver from various imaging modalities such as computed tomography, magnetic resonance imaging and ultrasound. Image analysis tasks like segmentation, object detection and classification for the liver, liver vessels and liver lesions are discussed. Based on the qualitative search, 91 papers were filtered out for the survey, including journal publications and conference proceedings. The papers reviewed in this work are grouped into eight categories based on the methodologies used. By comparing the evaluation metrics, hybrid models performed better for both the liver and the lesion segmentation tasks, ensemble classifiers performed better for the vessel segmentation tasks and combined approach performed better for both the lesion classification and detection tasks. The performance was measured based on the Dice score for the segmentation, and accuracy for the classification and detection tasks, which are the most commonly used metrics.publishedVersio
3D Imaging for Planning of Minimally Invasive Surgical Procedures
Novel minimally invasive surgeries are used for treating cardiovascular diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with fluoroscopic images for intraprocedural guidance is of clinical interest. Registration may be facilitated by rotating the C-arm to acquire 3D C-arm CT images. This dissertation describes the development of optimal scan and contrast parameters for C-arm CT in 6 swine. A 5-s ungated C-arm CT acquisition during rapid ventricular pacing with aortic root injection using minimal contrast (36 mL), producing high attenuation (1226), few artifacts (2.0), and measurements similar to those from MDCT (p\u3e0.05) was determined optimal. 3D MDCT and C-arm CT images were registered to overlay the aortic structures from MDCT onto fluoroscopic images for guidance in placing the prosthesis. This work also describes the development of a methodology to develop power equation (R2\u3e0.998) for estimating dose with C-arm CT based on applied tube voltage. Application in 10 patients yielded 5.48┬▒177 2.02 mGy indicating minimal radiation burden. For postprocedural follow-up, combinations of non-contrast, arterial, venous single energy CT (SECT) scans are used to monitor patients at multiple time intervals resulting in high cumulative radiation dose. Employing a single dual-energy CT (DECT) scan to replace two SECT scans can reduce dose. This work focuses on evaluating the feasibility of DECT imaging in the arterial phase. The replacement of non-contrast and arterial SECT acquisitions with one arterial DECT acquisition in 30 patients allowed generation of virtual non-contrast (VNC) images with 31 dose savings. Aortic luminal attenuation in VNC (32┬▒177 2 HU) was similar to true non-contrast images (35┬▒177 4 HU) indicating presence of unattenuated blood. To improve discrimination between c
3D Imaging for Planning of Minimally Invasive Surgical Procedures
Novel minimally invasive surgeries are used for treating cardiovascular diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with fluoroscopic images for intraprocedural guidance is of clinical interest. Registration may be facilitated by rotating the C-arm to acquire 3D C-arm CT images. This dissertation describes the development of optimal scan and contrast parameters for C-arm CT in 6 swine. A 5-s ungated C-arm CT acquisition during rapid ventricular pacing with aortic root injection using minimal contrast (36 mL), producing high attenuation (1226), few artifacts (2.0), and measurements similar to those from MDCT (p\u3e0.05) was determined optimal. 3D MDCT and C-arm CT images were registered to overlay the aortic structures from MDCT onto fluoroscopic images for guidance in placing the prosthesis. This work also describes the development of a methodology to develop power equation (R2\u3e0.998) for estimating dose with C-arm CT based on applied tube voltage. Application in 10 patients yielded 5.48┬▒177 2.02 mGy indicating minimal radiation burden. For postprocedural follow-up, combinations of non-contrast, arterial, venous single energy CT (SECT) scans are used to monitor patients at multiple time intervals resulting in high cumulative radiation dose. Employing a single dual-energy CT (DECT) scan to replace two SECT scans can reduce dose. This work focuses on evaluating the feasibility of DECT imaging in the arterial phase. The replacement of non-contrast and arterial SECT acquisitions with one arterial DECT acquisition in 30 patients allowed generation of virtual non-contrast (VNC) images with 31 dose savings. Aortic luminal attenuation in VNC (32┬▒177 2 HU) was similar to true non-contrast images (35┬▒177 4 HU) indicating presence of unattenuated blood. To improve discrimination between c
Recommended from our members
Photoacoustic image guidance and tissue characterization in cardiovascular applications
Collectively, cardiovascular diseases continue to be the leading cause of death, across nations and across decades. Improved diagnostic imaging methods offer promise to alleviate the morbidity associated with these diseases. Photoacoustic (PA) imaging is one such method, poised to make a significant impact on cardiovascular imaging, both as a research tool, as well as a clinical imaging modality. Offering the potential of molecular imaging in real-time, PA methods have been demonstrated in proof-of-concept studies tracking myocyte calcium dynamics. These results open the door to non-invasive longitudinal assessment of cardiac electrophysiological function, with implications for drug and contrast agent development. PA image guidance has also been extended to the characterization of cardiac radiofrequency ablation lesions. This method has been demonstrated to utilize endogenous chromophore changes resulting from ablation for the generation of depth-resolved tissue characterization maps, capable of assessing lesion extent. The technique has been subsequently validated by assessing high-intensity focused ultrasound ablation lesions in myocardium, with the hope for offering thermographic capabilities as well. While PA imaging offers such promise in cardiac ablation procedures, it is also in the process of clinical translation for image guidance and characterization in coronary artery disease applications. Research has shown, using Monte Carlo optical modeling, that using a simple dual-wavelength PA imaging technique has great potential for successful visualization of atherosclerotic plaques across multiple tissue types and at clinically relevant multiple millimeters of depth. Collectively these results offer a suite of PA imaging tools with the potential for molecular and thermographic imaging across a broad range of cardiovascular applications.Biomedical Engineerin
Characterization of alar ligament on 3.0T MRI: a cross-sectional study in IIUM Medical Centre, Kuantan
INTRODUCTION: The main purpose of the study is to compare the normal anatomy of alar
ligament on MRI between male and female. The specific objectives are to assess the prevalence
of alar ligament visualized on MRI, to describe its characteristics in term of its course, shape and
signal homogeneity and to find differences in alar ligament signal intensity between male and
female. This study also aims to determine the association between the heights of respondents
with alar ligament signal intensity and dimensions.
MATERIALS & METHODS: 50 healthy volunteers were studied on 3.0T MR scanner
Siemens Magnetom Spectra using 2-mm proton density, T2 and fat-suppression sequences. Alar
ligament is depicted in 3 planes and the visualization and variability of the ligament courses,
shapes and signal intensity characteristics were determined. The alar ligament dimensions were
also measured.
RESULTS: Alar ligament was best depicted in coronal plane, followed by sagittal and axial
planes. The orientations were laterally ascending in most of the subjects (60%), predominantly
oval in shaped (54%) and 67% showed inhomogenous signal. No significant difference of alar
ligament signal intensity between male and female respondents. No significant association was
found between the heights of the respondents with alar ligament signal intensity and dimensions.
CONCLUSION: Employing a 3.0T MR scanner, the alar ligament is best portrayed on coronal
plane, followed by sagittal and axial planes. However, tremendous variability of alar ligament as
depicted in our data shows that caution needs to be exercised when evaluating alar ligament,
especially during circumstances of injury
Case series of breast fillers and how things may go wrong: radiology point of view
INTRODUCTION: Breast augmentation is a procedure opted by women to overcome sagging
breast due to breastfeeding or aging as well as small breast size. Recent years have shown the
emergence of a variety of injectable materials on market as breast fillers. These injectable
breast fillers have swiftly gained popularity among women, considering the minimal
invasiveness of the procedure, nullifying the need for terrifying surgery. Little do they know
that the procedure may pose detrimental complications, while visualization of breast
parenchyma infiltrated by these fillers is also deemed substandard; posing diagnostic
challenges. We present a case series of three patients with prior history of hyaluronic acid and
collagen breast injections.
REPORT: The first patient is a 37-year-old lady who presented to casualty with worsening
shortness of breath, non-productive cough, central chest pain; associated with fever and chills
for 2-weeks duration. The second patient is a 34-year-old lady who complained of cough, fever
and haemoptysis; associated with shortness of breath for 1-week duration. CT in these cases
revealed non thrombotic wedge-shaped peripheral air-space densities.
The third patient is a 37‐year‐old female with right breast pain, swelling and redness for 2-
weeks duration. Previous collagen breast injection performed 1 year ago had impeded
sonographic visualization of the breast parenchyma. MRI breasts showed multiple non-
enhancing round and oval shaped lesions exhibiting fat intensity.
CONCLUSION: Radiologists should be familiar with the potential risks and hazards as well
as limitations of imaging posed by breast fillers such that MRI is required as problem-solving
tool