566 research outputs found

    3D cine DENSE MRI: ventricular segmentation and myocardial stratin analysis

    Get PDF
    Includes abstract. Includes bibliographical references

    Towards automating cine DENSE MRI image analysis : segmentation, tissue tracking and strain computation

    Get PDF
    Includes bibliographical references (p. 192-206).Over the past two decades, magnetic resonance imaging (MRI) has developed into a powerful imaging tool for the heart. Imaging cardiac morphology is now commonplace in clinical practice, and a plethora of quantitative techniques have also arisen on the research front. Myocardial tagging is an established quantitative cardiac MRI method that involves magnetically tagging the heart with a set of saturated bands, and monitoring the deformation of these bands as the heart contracts

    VALIDATION, OPTIMIZATION, AND IMAGE PROCESSING OF SPIRAL CINE DENSE MAGNETIC RESONANCE IMAGING FOR THE QUANTIFICATION OF LEFT AND RIGHT VENTRICULAR MECHANICS

    Get PDF
    Recent evidence suggests that cardiac mechanics (e.g. cardiac strains) are better measures of heart function compared to common clinical metrics like ejection fraction. However, commonly-used parameters of cardiac mechanics remain limited to just a few measurements averaged over the whole left ventricle. We hypothesized that recent advances in cardiac magnetic resonance imaging (MRI) could be extended to provide measures of cardiac mechanics throughout the left and right ventricles (LV and RV, respectively). Displacement Encoding with Stimulated Echoes (DENSE) is a cardiac MRI technique that has been validated for measuring LV mechanics at a magnetic field strength of 1.5 T but not at higher field strengths such as 3.0 T. However, it is desirable to perform DENSE at 3.0 T, which would yield a better signal to noise ratio for imaging the thin RV wall. Results in Chapter 2 support the hypothesis that DENSE has similar accuracy at 1.5 and 3.0 T. Compared to standard, clinical cardiac MRI, DENSE requires more expertise to perform and is not as widely used. If accurate mechanics could be measured from standard MRI, the need for DENSE would be reduced. However, results from Chapter 3 support the hypothesis that measured cardiac mechanics from standard MRI do not agree with, and thus cannot be used in place of, measurements from DENSE. Imaging the thin RV wall with its complex contraction pattern requires both three-dimensional (3D) measures of myocardial motion and higher resolution imaging. Results from Chapter 4 support the hypothesis that a lower displacement-encoding frequency can be used to allow for easier processing of 3D DENSE images. Results from Chapter 5 support the hypothesis that images with higher resolution (decreased blurring) can be achieved by using more spiral interleaves during the DENSE image acquisition. Finally, processing DENSE images to yield measures of cardiac mechanics in the LV is relatively simple due to the LV’s mostly cylindrical geometry. Results from Chapter 6 support the hypothesis that a local coordinate system can be adapted to the geometry of the RV to quantify mechanics in an equivalent manner as the LV. In summary, cardiac mechanics can now be quantified throughout the left and right ventricles using DENSE cardiac MRI

    Image based approach for early assessment of heart failure.

    Get PDF
    In diagnosing heart diseases, the estimation of cardiac performance indices requires accurate segmentation of the left ventricle (LV) wall from cine cardiac magnetic resonance (CMR) images. MR imaging is noninvasive and generates clear images; however, it is impractical to manually process the huge number of images generated to calculate the performance indices. In this dissertation, we introduce a novel, fast, robust, bi-directional coupled parametric deformable models that are capable of segmenting the LV wall borders using first- and second-order visual appearance features. These features are embedded in a new stochastic external force that preserves the topology of the LV wall to track the evolution of the parametric deformable models control points. We tested the proposed segmentation approach on 15 data sets in 6 infarction patients using the Dice similarity coefficient (DSC) and the average distance (AD) between the ground truth and automated segmentation contours. Our approach achieves a mean DSC value of 0.926±0.022 and mean AD value of 2.16±0.60 mm compared to two other level set methods that achieve mean DSC values of 0.904±0.033 and 0.885±0.02; and mean AD values of 2.86±1.35 mm and 5.72±4.70 mm, respectively. Also, a novel framework for assessing both 3D functional strain and wall thickening from 4D cine cardiac magnetic resonance imaging (CCMR) is introduced. The introduced approach is primarily based on using geometrical features to track the LV wall during the cardiac cycle. The 4D tracking approach consists of the following two main steps: (i) Initially, the surface points on the LV wall are tracked by solving a 3D Laplace equation between two subsequent LV surfaces; and (ii) Secondly, the locations of the tracked LV surface points are iteratively adjusted through an energy minimization cost function using a generalized Gauss-Markov random field (GGMRF) image model in order to remove inconsistencies and preserve the anatomy of the heart wall during the tracking process. Then the circumferential strains are straight forward calculated from the location of the tracked LV surface points. In addition, myocardial wall thickening is estimated by co-allocation of the corresponding points, or matches between the endocardium and epicardium surfaces of the LV wall using the solution of the 3D laplace equation. Experimental results on in vivo data confirm the accuracy and robustness of our method. Moreover, the comparison results demonstrate that our approach outperforms 2D wall thickening estimation approaches

    Quantification in cardiac MRI: advances in image acquisition and processing

    Get PDF
    Cardiac magnetic resonance (CMR) imaging enables accurate and reproducible quantification of measurements of global and regional ventricular function, blood flow, perfusion at rest and stress as well as myocardial injury. Recent advances in MR hardware and software have resulted in significant improvements in image quality and a reduction in imaging time. Methods for automated and robust assessment of the parameters of cardiac function, blood flow and morphology are being developed. This article reviews the recent advances in image acquisition and quantitative image analysis in CMR

    Motion tracking tMRI datasets to quantify abnormal left ventricle motion using finite element modelling

    Get PDF
    According to `The Atlas of Heart Disease and Stroke'[MMMG04] published by the World Health Organization, heart disease accounts for nearly half the deaths in both the developed and developing countries and is the world's single biggest killer. However, early detection of a diseased heart condition can prevent many of these fatalities. Regional wall motion abnormalities of the heart precede both ECG abnormalities and chest pain as an indicator of myocardial ischaemia and are an excellent indicator of coronary stenosis [GZM97]. These motion abnormalities of the heart muscle are difficult to observe and track, because the heart is a relatively smooth organ with few landmarks and non-rigid motion with a twisting motion or tangential component. The MRI tissue-tagging technique gives researchers the first glimpse into how the heart actually beats. This research uses the tagged MRI images of the heart to create a three dimensional model of a beating heart indicating the stress of a region. Tagged MRI techniques are still developing and vary vastly, meaning that there needs to be a methodology that can adapt to these changes rapidly and effectively, to meet the needs of the evolving technology. The focus of this research is to develop and test such a methodology by the means of a Strain Estimation Pipeline along with an effective way of validating any changes made to the individual processes that it comprises of

    Myocardial tagging by Cardiovascular Magnetic Resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications

    Get PDF
    Cardiovascular magnetic resonance (CMR) tagging has been established as an essential technique for measuring regional myocardial function. It allows quantification of local intramyocardial motion measures, e.g. strain and strain rate. The invention of CMR tagging came in the late eighties, where the technique allowed for the first time for visualizing transmural myocardial movement without having to implant physical markers. This new idea opened the door for a series of developments and improvements that continue up to the present time. Different tagging techniques are currently available that are more extensive, improved, and sophisticated than they were twenty years ago. Each of these techniques has different versions for improved resolution, signal-to-noise ratio (SNR), scan time, anatomical coverage, three-dimensional capability, and image quality. The tagging techniques covered in this article can be broadly divided into two main categories: 1) Basic techniques, which include magnetization saturation, spatial modulation of magnetization (SPAMM), delay alternating with nutations for tailored excitation (DANTE), and complementary SPAMM (CSPAMM); and 2) Advanced techniques, which include harmonic phase (HARP), displacement encoding with stimulated echoes (DENSE), and strain encoding (SENC). Although most of these techniques were developed by separate groups and evolved from different backgrounds, they are in fact closely related to each other, and they can be interpreted from more than one perspective. Some of these techniques even followed parallel paths of developments, as illustrated in the article. As each technique has its own advantages, some efforts have been made to combine different techniques together for improved image quality or composite information acquisition. In this review, different developments in pulse sequences and related image processing techniques are described along with the necessities that led to their invention, which makes this article easy to read and the covered techniques easy to follow. Major studies that applied CMR tagging for studying myocardial mechanics are also summarized. Finally, the current article includes a plethora of ideas and techniques with over 300 references that motivate the reader to think about the future of CMR tagging
    corecore