5 research outputs found
Automated Anomaly Detection in Distribution Grids Using uPMU Measurements
The impact of Phasor Measurement Units (PMUs) for providing situational awareness to transmission system operators \ has been widely documented. Micro-PMUs (uPMUs) \ are an emerging sensing technology that can provide similar \ benefits to Distribution System Operators (DSOs), enabling a \ level of visibility into the distribution grid that was previously \ unattainable. In order to support the deployment of these \ high resolution sensors, the automation of data analysis and \ prioritizing communication to the DSO becomes crucial. In this \ paper, we explore the use of uPMUs to detect anomalies on \ the distribution grid. Our methodology is motivated by growing \ concern about failures and attacks to distribution automation \ equipment. The effectiveness of our approach is demonstrated \ through both real and simulated data
Security Analysis of Interdependent Critical Infrastructures: Power, Cyber and Gas
abstract: Our daily life is becoming more and more reliant on services provided by the infrastructures
power, gas , communication networks. Ensuring the security of these
infrastructures is of utmost importance. This task becomes ever more challenging as
the inter-dependence among these infrastructures grows and a security breach in one
infrastructure can spill over to the others. The implication is that the security practices/
analysis recommended for these infrastructures should be done in coordination.
This thesis, focusing on the power grid, explores strategies to secure the system that
look into the coupling of the power grid to the cyber infrastructure, used to manage
and control it, and to the gas grid, that supplies an increasing amount of reserves to
overcome contingencies.
The first part (Part I) of the thesis, including chapters 2 through 4, focuses on
the coupling of the power and the cyber infrastructure that is used for its control and
operations. The goal is to detect malicious attacks gaining information about the
operation of the power grid to later attack the system. In chapter 2, we propose a
hierarchical architecture that correlates the analysis of high resolution Micro-Phasor
Measurement Unit (microPMU) data and traffic analysis on the Supervisory Control
and Data Acquisition (SCADA) packets, to infer the security status of the grid and
detect the presence of possible intruders. An essential part of this architecture is
tied to the analysis on the microPMU data. In chapter 3 we establish a set of anomaly
detection rules on microPMU data that
flag "abnormal behavior". A placement strategy
of microPMU sensors is also proposed to maximize the sensitivity in detecting anomalies.
In chapter 4, we focus on developing rules that can localize the source of an events
using microPMU to further check whether a cyber attack is causing the anomaly, by
correlating SCADA traffic with the microPMU data analysis results. The thread that
unies the data analysis in this chapter is the fact that decision are made without fully estimating the state of the system; on the contrary, decisions are made using
a set of physical measurements that falls short by orders of magnitude to meet the
needs for observability. More specifically, in the first part of this chapter (sections 4.1-
4.2), using microPMU data in the substation, methodologies for online identification of
the source Thevenin parameters are presented. This methodology is used to identify
reconnaissance activity on the normally-open switches in the substation, initiated
by attackers to gauge its controllability over the cyber network. The applications
of this methodology in monitoring the voltage stability of the grid is also discussed.
In the second part of this chapter (sections 4.3-4.5), we investigate the localization
of faults. Since the number of PMU sensors available to carry out the inference
is insufficient to ensure observability, the problem can be viewed as that of under-sampling
a "graph signal"; the analysis leads to a PMU placement strategy that can
achieve the highest resolution in localizing the fault, for a given number of sensors.
In both cases, the results of the analysis are leveraged in the detection of cyber-physical
attacks, where microPMU data and relevant SCADA network traffic information
are compared to determine if a network breach has affected the integrity of the system
information and/or operations.
In second part of this thesis (Part II), the security analysis considers the adequacy
and reliability of schedules for the gas and power network. The motivation for
scheduling jointly supply in gas and power networks is motivated by the increasing
reliance of power grids on natural gas generators (and, indirectly, on gas pipelines)
as providing critical reserves. Chapter 5 focuses on unveiling the challenges and
providing solution to this problem.Dissertation/ThesisDoctoral Dissertation Electrical Engineering 201
Wireless Sensor Data Transport, Aggregation and Security
abstract: Wireless sensor networks (WSN) and the communication and the security therein have been gaining further prominence in the tech-industry recently, with the emergence of the so called Internet of Things (IoT). The steps from acquiring data and making a reactive decision base on the acquired sensor measurements are complex and requires careful execution of several steps. In many of these steps there are still technological gaps to fill that are due to the fact that several primitives that are desirable in a sensor network environment are bolt on the networks as application layer functionalities, rather than built in them. For several important functionalities that are at the core of IoT architectures we have developed a solution that is analyzed and discussed in the following chapters.
The chain of steps from the acquisition of sensor samples until these samples reach a control center or the cloud where the data analytics are performed, starts with the acquisition of the sensor measurements at the correct time and, importantly, synchronously among all sensors deployed. This synchronization has to be network wide, including both the wired core network as well as the wireless edge devices. This thesis studies a decentralized and lightweight solution to synchronize and schedule IoT devices over wireless and wired networks adaptively, with very simple local signaling. Furthermore, measurement results have to be transported and aggregated over the same interface, requiring clever coordination among all nodes, as network resources are shared, keeping scalability and fail-safe operation in mind. Furthermore ensuring the integrity of measurements is a complicated task. On the one hand Cryptography can shield the network from outside attackers and therefore is the first step to take, but due to the volume of sensors must rely on an automated key distribution mechanism. On the other hand cryptography does not protect against exposed keys or inside attackers. One however can exploit statistical properties to detect and identify nodes that send false information and exclude these attacker nodes from the network to avoid data manipulation. Furthermore, if data is supplied by a third party, one can apply automated trust metric for each individual data source to define which data to accept and consider for mentioned statistical tests in the first place. Monitoring the cyber and physical activities of an IoT infrastructure in concert is another topic that is investigated in this thesis.Dissertation/ThesisDoctoral Dissertation Electrical Engineering 201