418 research outputs found

    Spatio-chromatic vision with multifocal diffractive intraocular lens

    Get PDF
    Background This study aims to detect alterations in the spatio-chromatic pseudophakic vision produced by multifocal diffractive intraocular lenses (IOLs) and provides a physical interpretation. Methods In vitro characterization of the imaging performance of two diffractive IOLs: AT LISA Tri (Zeiss) and FineVision (PhysIOL) in on-bench model eye illuminated with red (R, 625 nm), green (G, 530 nm) and blue (B, 455 nm) lights. We used the metrics: energy efficiency (EE), area under the modulation transfer function, longitudinal chromatic aberration (LCA), and halo intensity. Through-focus (TF) analysis and calculation of the expected defocus curve under white (W) daylight were included. In vivo visual acuity (VA) of 50 pseudophakics (60 eyes) was assessed under W, R, G, B lights at far and near. Two clinical experiments evaluated LCA and R, G, B TF-EE effects on pseudophakic vision and their relative importance. Results Clinical mean VA values under W light agreed with the predicted values at far and near for both IOLs. LCA measurements and R, G, B TF-EE curves were consistent with their lens design based on the 0th and 1st diffraction orders operative for far and near vision, respectively. LCA effects were compensated at near but noticed at far (-¿0.75 D under B light). We detected strong asymmetry in visual resolution depending on the object distance and the illuminating wavelength—red predominance at far, blue predominance at near—in consistency with the TF-EE measurements. Conclusions Diffractive multifocal IOL designs produce asymmetries in the spatio-chromatic vision of pseudophakics beyond the alterations strictly due to LCA. VA asymmetry for far/near object distance under R and B illumination is clinically detectable in subjects implanted with IOLs with 0th and 1st diffraction orders for far and near vision, respectively. Such VA asymmetry cannot be explained solely from the influence of defocus, as would be derived from a chromatic difference of power, but mainly from the wavelength dependence of the EE.Agencia Estatal de Investigación from Spanish Government (Grant No. PID2020-114582RB-I00/AEI/10. 13039/501100011033).Peer ReviewedPostprint (published version

    Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling

    Get PDF
    Intraocular lenses (IOLs) are used in the cataract treatment for surgical replacement of the opacified crystalline lens. Before being implanted they have to pass the strict quality control to guarantee a good biomechanical stability inside the capsular bag, avoiding the rotation, and to provide a good optical quality. The goal of this study was to investigate the influence of the material and haptic design on the behavior of the IOLs under dynamic compression condition. For this purpose, the strain-stress characteristics of the hydrophobic and hydrophilic materials were estimated experimentally. Next, these data were used as the input for a finite-element model (FEM) to analyze the stability of different IOL haptic designs, according to the procedure described by the ISO standards. Finally, the simulations of the effect of IOL tilt and decentration on the optical performance were performed in an eye model using a ray-tracing software. The results suggest the major importance of the haptic design rather than the material on the postoperative behavior of an IOL. FEM appears to be a powerful tool for numerical studies of the biomechanical properties of IOLs and it allows one to help in the design phase to the manufacturers

    Straylight as additional indicator for visual function assessment and clinical decision making

    Get PDF

    Straylight as additional indicator for visual function assessment and clinical decision making

    Get PDF

    Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients

    Get PDF
    This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R2 > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability

    Evaluation of modern intraocular lenses

    Get PDF
    Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A standardised defocus area metric and reading performance index metric were devised for the evaluation of the range of focus and the reading ability of subjects implanted with presbyopic correcting IOLs. The range of clear vision after implantation of an MIOL is extended by a second focal point; however, this results in the prevalence of dysphotopsia. A bespoke halometer was designed and validated to assess this photopic phenomenon. There is a lack of standardisation in the methods used for determining IOL orientation and thus rotation. A repeatable, objective method was developed to allow the accurate assessment of IOL rotation, which was used to determine the rotational and positional stability of a closed loop haptic IOL. A new commercially available biometry device was validated for use with subjects prior to cataract surgery. The optical low coherence reflectometry instrument proved to be a valid method for assessing ocular biometry and covered a wider range of ocular parameters in comparison with previous instruments. The advantages of MIOLs were shown to include an extended range of clear vision translating into greater reading ability. However, an increased prevalence of dysphotopsia was shown with a bespoke halometer, which was dependent on the MIOL optic design. Implantation of a single optic accommodating IOL did not improve reading ability but achieved high subjective ratings of near vision. The closed-loop haptic IOL displayed excellent rotational stability in the late period but relatively poor rotational stability in the early period post implantation. The orientation error was compounded by the high frequency of positional misalignment leading to an extensive overall misalignment of the IOL. This thesis demonstrates the functionality of new IOL lens designs and the importance of standardised testing methods, thus providing a greater understanding of the consequences of implanting these IOLs. Consequently, the findings of the thesis will influence future designs of IOLs and testing methods

    Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design

    Get PDF
    The optical quality of a set of IOLs (modeling set: one monofocal and two bifocals) was assessed through focus by the area under the modulation transfer function (MTFa) metric and related to the visual acuity (VA) defocus curves of pseudophakic patients implanted with said IOLs. A non-linear relationship between the MTFa and clinical VA was obtained with an asymptotic limit found to be the best VA achievable by the patients. Two mathematical fitting functions between clinical VA and MTFa were derived with high correlation coefficients (R-2 >= 0.85). They were applied to the MTFa obtained from a different set of IOLs with advanced designs (trial set: one extended range of vision -ERV-, one trifocal ERV and one trifocal apodized) to predict VA versus defocus of patients implanted with these IOLs. Differences between the calculated VA and the clinical VA for both fitting models were within the standard deviation of the clinical measurements in the range of -3.00 D to 0.00 D defocus. thus proving the suitability of the MTFa metric to predict clinical VA performance of new IOL designs. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreemen

    Full OCT anterior segment biometry: An application in cataract surgery

    Get PDF
    In vivo three-dimensional (3-D) anterior segment biometry before and after cataract surgery was analyzed by using custom highresolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT). The system was provided with custom algorithms for denoising, segmentation, full distortion correction (fan and optical) and merging of the anterior segment volumes (cornea, iris, and crystalline lens or IOL), to provide fully quantitative data of the anterior segment of the eye. The method was tested on an in vitro artificial eye with known surfaces geometry at different orientations and demonstrated on an aging cataract patient in vivo. Biometric parameters CCT, ACD/ILP, CLT/ILT Tilt and decentration are retrieved with a very high degree of accuracy. IOL was placed 400 οm behind the natural crystalline lens, The IOL was aligned with a similar orientation of the natural lens (2.47 deg superiorly), but slightly lower amounts (0.77 deg superiorly). The IOL was decentered superiorly (0.39 mm) and nasally (0.26 mm). © 2013 Optical Society of America.This study has been funded by Spanish Government Grant FIS2011-25637 and European Research Council Grant ERC-2011-AdG-294099 to S. Marcos.Peer Reviewe
    • …
    corecore