490 research outputs found

    Distribution power loss minimization via distributed generation, capacitor and network reconfiguration

    Get PDF
    This paper presents a solution to solve the network reconfiguration, DG coordination (location and size) and capacitor coordination (location and size), simultaneously. The proposed solution will be determined by using Artificial Bee Colony (ABC). Various case studies are presented to see the impact on the test system, in term of power loss reduction and also voltage profiles. The proposed approach is applied to a 33-bus test system and simulate by using MATLAB programming. The simulation results show that combination of DG, capacitor and network reconfiguration gives a positive impact on total power losses minimization as well as voltage profile improvement compared to other case studies

    Optimal Capacitor Placement in Radial Distribution Systems using Artificial Bee Colony (ABC) Algorithm

    Get PDF
    This paper presents a new method which applies an artificial bee colony algorithm (ABC) for capacitor placement in distribution systems with an objective of improving the voltage profile and reduction of power loss. The solution methodology has two parts: in part one the loss sensitivity factors are used to select the candidate locations for the capacitor placement and in part two a new algorithm called Artificial Bee Colony Algorithm(ABC) is used to estimate the optimal size of capacitors at the optimal buses determined in part one. The ABC algorithm is a new population based meta heuristic approach inspired by intelligent foraging behavior of honeybee swarm. The advantage of ABC algorithm is that it does not require external parameters such as cross over rate and mutation rate as in case of genetic algorithm and differential evolution and it is hard to determine these parameters in prior. The other advantage is that the global search ability in the algorithm is implemented by introducing neighborhood source production mechanism which is a similar to mutation process. To demonstrate the validity of the proposed algorithm, computer simulations are carried out on 34-bus system and compared the results with the other approach available in the literature. The proposed method has outperformed the other methods in terms of the quality of solution and computational efficiency

    A Novel Analytical Technique for Optimal Allocation of Capacitors in Radial Distribution Systems

    Get PDF
    In this paper, a novel analytical technique is proposed to determine the optimal size and location of shunt capacitor units in radial distribution systems. An objective function is formulated to reduce real power loss, to improve thevoltage profile and to increase annual cost savings. A new constant, the Loss Sensitivity Constant (LSC), is proposed here. The value of LSC decides the location and size of candidate buses. The technique is demonstrated on an IEEE-33 bus system at different load levels and the 130-bus distribution system of Jamawa Ramgarh village, Jaipur city. The obtained results are compared with the latest optimization techniques to show the effectiveness and robustness of the proposed technique

    Genetic-Moth Swarm Algorithm for Optimal Placement and Capacity of Renewable DG Sources in Distribution Systems

    Get PDF
    This paper presents a hybrid approach based on the Genetic Algorithm (GA) and Moth Swarm Algorithm (MSA), namely Genetic Moth Swarm Algorithm (GMSA), for determining the optimal location and sizing of renewable distributed generation (DG) sources on radial distribution networks (RDN). Minimizing the electrical power loss within the framework of system operation and under security constraints is the main objective of this study. In the proposed technique, the global search ability has been regulated by the incorporation of GA operations with adaptive mutation operator on the reconnaissance phase using genetic pathfinder moths. In addition, the selection of artificial light sources has been expanded over the swarm. The representation of individuals within the three phases of MSA has been modified in terms of quality and ratio. Elite individuals have been used to play different roles in order to reduce the design space and thus increase the exploitation ability. The developed GMSA has been applied on different scales of standard RDN of the (33 and 69-bus) power systems. Firstly, the most adequate buses for installing DGs are suggested using Voltage Stability Index (VSI). Then the proposed GMSA is applied to reduce real power generation, power loss, and total system cost, in addition, to improve the minimum bus voltage and the annual net saving by selecting the DGs size and their locations. Furthermore, GMSA is compared with other literature methods under several power system constraints and conditions, in single and multi-objective optimization space. The computational results prove the effectiveness and superiority of the GMSA with respect to power loss reduction and voltage profile enhancement using a minimum size of renewable DG units

    Optimal Allocation of Capacitor Bank in Radial Distribution System using Analytical Approach

    Get PDF
    In this paper, a novel analytical technique is proposed for optimal allocation of shunt capacitor bank in radial distribution system. An objective function is formulated to determine the optimal size, number and location of capacitor bank for real & reactive power loss reduction, voltage profile enhancement and annual cost saving. A new constant, Power Voltage Sensitivity Constant (PVSC), has been proposed here. The value of PVSC constant decides the candidate bus location and size. The achievability of the proposed method has been demonstrated on IEEE-69 bus and real distribution system of Jamawaramgarh, Jaipur city. The obtained results are compared with latest optimization techniques to show the effectiveness and robustness of the proposed technique

    Improvement of voltage profile for large scale power system using soft computing approach

    Get PDF
    In modern power system operation and planning, reactive power is an important part of power system operation to supply electrical load such as an electric motor. However, the reactive current that flows from the generator to load demand can cause voltage drop and active power loss. Hence, it is essential to install a compensating device such as a shunt capacitor close to the load bus to reduce the total power loss of the transmission line and improve the voltage stability of the system. This paper presents the application of a genetic algorithm (GA), particle swarm optimization (PSO), and artificial bee colony (ABC)) to obtain the optimal size of the shunt capacitor where those capacitors are located on the critical bus. To examine the efficacy of the proposed algorithm, Java-Madura-Bali (JAMALI) 500kV power system grid is used as the test system. From the simulation results, the use of PSO and ABC algorithms to obtain the sizing of the capacitor’s capacity can reduce the power loss of around 15.873 MW. Moreover, a different result is showed by the GA approach where the power loss in the JAMALI 500kV power grid can be compressed only up to 15.54 MW or 11.38% from the power system operation without a shunt capacitor. The three soft computing techniques could also maintain the voltage profile within 1.05 p.u and 0.95 p.u

    Assessment of renewable distributed generation in green building rating system for public hospital

    Get PDF
    This paper presents an optimization solution for renewable Distributed Generation (DG), as imposed in the Green Building Rating System (GBRS) for a public hospital. Solar photovoltaic DG unit (PV-DG) is identified as a type of DG used in this paper. The proposed optimization via PV-DG coordination will improve the sustainable energy performance of the green building by power loss reduction within accepted lower losses region using Artificial Bee Colony (ABC) algorithm. The setup input data from one of Malaysian public hospitals’ power distribution system is been adopted and simulation results via MATLAB programming show that the optimization of DG forming into bigger-scale imposed system provides a better outcome in minimization of total power losses within appropriate voltage profile as compared to current PV-DG imposed in GBRS. The objective function representing total power losses which also supported by related literature give a measure that forming sufficient and optimal PV-DG assessment criteria is highly important, thus, current PV-DG assessment in GBRS is proposed to be reviewed into new parameter setting for public hospital due to its’ high energy demand and distinctive electrical load profile

    Distribution power loss minimization via optimal sizing and placement of shunt capacitor and distributed generator with network reconfiguration

    Get PDF
    The population is speeding up and the demands for electrical energy are clearly increasing, this growth in load leads to higher power loss and Voltage drop. This paper is focused on a method to decrease the power losses and voltage profile improvement. The first suggested technique binary particle swarm optimization BPSO is utilized for solving the problem of the power loss minimization in network distribution. This work based on optimum position and sizing of the distribution generation (DG) units, shunt capacitor (SC) with network reconfiguration is applied to show the improvement of the network distribution efficiency. The MATLAB programming part and software package MATPOWER7 are used to simulate 69-bus and 33-bus test system with three different cases of loads and different number of DG and SC. The result showed a positive impact on system efficiency in comparison with other previous studies. This paper showed that increase of DG and capacitor does not usually give the best result although the increase of system cost, maintenance, and the units' distance for gas supplying
    • …
    corecore