1,937 research outputs found
Arrhythmia Evaluation in Wearable ECG Devices
This study evaluates four databases from PhysioNet: The American Heart Association database (AHADB), Creighton University Ventricular Tachyarrhythmia database (CUDB), MIT-BIH Arrhythmia database (MITDB), and MIT-BIH Noise Stress Test database (NSTDB). The ANSI/AAMI EC57:2012 is used for the evaluation of the algorithms for the supraventricular ectopic beat (SVEB), ventricular ectopic beat (VEB), atrial fibrillation (AF), and ventricular fibrillation (VF) via the evaluation of the sensitivity, positive predictivity and false positive rate. Sample entropy, fast Fourier transform (FFT), and multilayer perceptron neural network with backpropagation training algorithm are selected for the integrated detection algorithms. For this study, the result for SVEB has some improvements compared to a previous study that also utilized ANSI/AAMI EC57. In further, VEB sensitivity and positive predictivity gross evaluations have greater than 80%, except for the positive predictivity of the NSTDB database. For AF gross evaluation of MITDB database, the results show very good classification, excluding the episode sensitivity. In advanced, for VF gross evaluation, the episode sensitivity and positive predictivity for the AHADB, MITDB, and CUDB, have greater than 80%, except for MITDB episode positive predictivity, which is 75%. The achieved results show that the proposed integrated SVEB, VEB, AF, and VF detection algorithm has an accurate classification according to ANSI/AAMI EC57:2012. In conclusion, the proposed integrated detection algorithm can achieve good accuracy in comparison with other previous studies. Furthermore, more advanced algorithms and hardware devices should be performed in future for arrhythmia detection and evaluation.Cal-Comp Electronics & Communications Co., Ltd.; Kinpo Electronics, Inc. New Taipei City, Taiwan. Innovation Center for Big Data and Digital Convergence; Yuan Ze University, Taiwan
Unsupervised Heart-rate Estimation in Wearables With Liquid States and A Probabilistic Readout
Heart-rate estimation is a fundamental feature of modern wearable devices. In
this paper we propose a machine intelligent approach for heart-rate estimation
from electrocardiogram (ECG) data collected using wearable devices. The novelty
of our approach lies in (1) encoding spatio-temporal properties of ECG signals
directly into spike train and using this to excite recurrently connected
spiking neurons in a Liquid State Machine computation model; (2) a novel
learning algorithm; and (3) an intelligently designed unsupervised readout
based on Fuzzy c-Means clustering of spike responses from a subset of neurons
(Liquid states), selected using particle swarm optimization. Our approach
differs from existing works by learning directly from ECG signals (allowing
personalization), without requiring costly data annotations. Additionally, our
approach can be easily implemented on state-of-the-art spiking-based
neuromorphic systems, offering high accuracy, yet significantly low energy
footprint, leading to an extended battery life of wearable devices. We
validated our approach with CARLsim, a GPU accelerated spiking neural network
simulator modeling Izhikevich spiking neurons with Spike Timing Dependent
Plasticity (STDP) and homeostatic scaling. A range of subjects are considered
from in-house clinical trials and public ECG databases. Results show high
accuracy and low energy footprint in heart-rate estimation across subjects with
and without cardiac irregularities, signifying the strong potential of this
approach to be integrated in future wearable devices.Comment: 51 pages, 12 figures, 6 tables, 95 references. Under submission at
Elsevier Neural Network
Design and evaluation of a person-centric heart monitoring system over fog computing infrastructure
Heart disease and stroke are becoming the leading cause of death worldwide. Electrocardiography monitoring devices (ECG) are the only tool that helps physicians diagnose cardiac abnormalities. Although the design of ECGs has followed closely the electronics miniaturization evolution over the years, existing wearable ECG have limited accuracy and rely on external resources to analyze the signal and evaluate heart activity. In this paper, we work towards empowering the wearable device with processing capabilities to locally analyze the signal and identify abnormal behavior. The ability to differentiate between normal and abnormal heart activity significantly reduces (a) the need to store the signals, (b) the data transmitted to the cloud and (c) the overall power consumption. Based on this concept, the HEART platform is presented that combines wearable embedded devices, mobile edge devices, and cloud services to provide on-the-spot, reliable, accurate and instant monitoring of the heart. The performance of the system is evaluated concerning the accuracy of detecting abnormal events and the power consumption of the wearable device. Results indicate that a very high percentage of success can be achieved in terms of event detection ratio and the device being operative up to a several days without the need for a recharge
Fog Computing in Medical Internet-of-Things: Architecture, Implementation, and Applications
In the era when the market segment of Internet of Things (IoT) tops the chart
in various business reports, it is apparently envisioned that the field of
medicine expects to gain a large benefit from the explosion of wearables and
internet-connected sensors that surround us to acquire and communicate
unprecedented data on symptoms, medication, food intake, and daily-life
activities impacting one's health and wellness. However, IoT-driven healthcare
would have to overcome many barriers, such as: 1) There is an increasing demand
for data storage on cloud servers where the analysis of the medical big data
becomes increasingly complex, 2) The data, when communicated, are vulnerable to
security and privacy issues, 3) The communication of the continuously collected
data is not only costly but also energy hungry, 4) Operating and maintaining
the sensors directly from the cloud servers are non-trial tasks. This book
chapter defined Fog Computing in the context of medical IoT. Conceptually, Fog
Computing is a service-oriented intermediate layer in IoT, providing the
interfaces between the sensors and cloud servers for facilitating connectivity,
data transfer, and queryable local database. The centerpiece of Fog computing
is a low-power, intelligent, wireless, embedded computing node that carries out
signal conditioning and data analytics on raw data collected from wearables or
other medical sensors and offers efficient means to serve telehealth
interventions. We implemented and tested an fog computing system using the
Intel Edison and Raspberry Pi that allows acquisition, computing, storage and
communication of the various medical data such as pathological speech data of
individuals with speech disorders, Phonocardiogram (PCG) signal for heart rate
estimation, and Electrocardiogram (ECG)-based Q, R, S detection.Comment: 29 pages, 30 figures, 5 tables. Keywords: Big Data, Body Area
Network, Body Sensor Network, Edge Computing, Fog Computing, Medical
Cyberphysical Systems, Medical Internet-of-Things, Telecare, Tele-treatment,
Wearable Devices, Chapter in Handbook of Large-Scale Distributed Computing in
Smart Healthcare (2017), Springe
Detecting and monitoring arrhythmia recurrence following catheter ablation of atrial fibrillation.
Atrial fibrillation (AF) is the most common arrhythmia prompting clinical presentation, is associated with significant morbidity and mortality. The incidence and prevalence of this arrhythmia is expected to grow significantly in the coming decades. Of the available pharmacologic and non-pharmacologic treatment options, the fastest growing and most intensely studied is catheter-based ablation therapy for AF. Given the varying success rates for AF ablation, the increasingly complex factors that need to be taken into account when deciding to proceed with ablation, as well as varying definitions of procedural success, accurate detection of arrhythmia recurrence and its burden is of significance. Detecting and monitoring AF recurrence following catheter ablation is therefore an important consideration. Multiple studies have demonstrated the close relationship between the intensity of rhythm monitoring with wearable ambulatory cardiac monitors, or implantable cardiac rhythm monitors and the detection of arrhythmia recurrence. Other studies have employed algorithms dependent on intensive monitoring and arrhythmia detection in the decision tree on whether to proceed with repeat ablation or medical therapy. In this review, we discuss these considerations, types of monitoring devices, and implications for monitoring AF recurrence following catheter ablation
On the Deployment of Healthcare Applications over Fog Computing Infrastructure
Fog computing is considered as the most promising enhancement of the traditional cloud computing paradigm in order to handle potential issues introduced by the emerging Interned of Things (IoT) framework at the network edge. The heterogeneous nature, the extensive distribution and the hefty number of deployed IoT nodes will disrupt existing functional models, creating confusion. However, IoT will facilitate the rise of new applications, with automated healthcare monitoring platforms being amongst them. This paper presents the pillars of design for such applications, along with the evaluation of a working prototype that collects ECG traces from a tailor-made device and utilizes the patient's smartphone as a Fog gateway for securely sharing them to other authorized entities. This prototype will allow patients to share information to their physicians, monitor their health status independently and notify the authorities rapidly in emergency situations. Historical data will also be available for further analysis, towards identifying patterns that may improve medical diagnoses in the foreseeable future
- …