1,474 research outputs found

    DeSyRe: on-Demand System Reliability

    No full text
    The DeSyRe project builds on-demand adaptive and reliable Systems-on-Chips (SoCs). As fabrication technology scales down, chips are becoming less reliable, thereby incurring increased power and performance costs for fault tolerance. To make matters worse, power density is becoming a significant limiting factor in SoC design, in general. In the face of such changes in the technological landscape, current solutions for fault tolerance are expected to introduce excessive overheads in future systems. Moreover, attempting to design and manufacture a totally defect and fault-free system, would impact heavily, even prohibitively, the design, manufacturing, and testing costs, as well as the system performance and power consumption. In this context, DeSyRe delivers a new generation of systems that are reliable by design at well-balanced power, performance, and design costs. In our attempt to reduce the overheads of fault-tolerance, only a small fraction of the chip is built to be fault-free. This fault-free part is then employed to manage the remaining fault-prone resources of the SoC. The DeSyRe framework is applied to two medical systems with high safety requirements (measured using the IEC 61508 functional safety standard) and tight power and performance constraints

    Compiler-Aided Methodology for Low Overhead On-line Testing

    Get PDF
    Reliability is emerging as an important design criterion in modern systems due to increasing transient fault rates. Hardware fault-tolerance techniques, commonly used to address this, introduce high design costs. As alternative, software Signature-Monitoring (SM) schemes based on compiler assertions are an efficient method for control-flow-error detection. Existing SM techniques do not consider application-specific-information causing unnecessary overheads. In this paper, compile-time Control-Flow-Graph (CFG) topology analysis is used to place best-suited assertions at optimal locations of the assembly code to reduce overheads. Our evaluation with representative workloads shows fault-coverage increase with overheads close to Assertion- based Control-Flow Correction (ACFC), the method with lowest overhead. Compared to ACFC, our technique improves (on average) fault coverage by 17%, performance overhead by 5% and power-consumption by 3% with equal code-size overhead

    Front-End Monitoring of Multiple Loads in Wireless Power Transfer Systems Without Wireless Communication Systems

    Get PDF
    5siThis paper describes a method for monitoring multiple loads from the front end of a wireless power transfer system without using any wireless communication systems. A mathematical approach based on scanning the frequency around the resonant frequency has been developed for deriving the load conditions. The proposal requires only information of the input voltage and current, thereby eliminating the requirements of using wireless communication systems for feedback control. The proposal has been practically confirmed in hardware prototype with good results.reservedmixedYin, J.; Lin, D.; Lee, C. K.; Parisini, T.; Hui, S. Y. R.Yin, J.; Lin, D.; Lee, C. K.; Parisini, Thomas; Hui, S. Y. R

    Conception pour la testabilité des systèmes biomédicaux implantables

    Get PDF
    Architecture générale des systèmes implantables -- Principes de stimulation électrique -- Champs d'application des systèmes implantables -- Les particularités des circuits implantables -- Tendance future -- Conception pour la testabilité de la partie numérique des circuits implantables -- "Desigh and realization of an accurate built-in current sensor for Iddq testing and power dissipation measurement -- Conception pour la testabilité de la partie analogique des circuits implantables -- BIST for digital-to-analog and Analogo-to-digital converters -- Efficient and accurate testing of analog-to-digital converters using oscillation test method -- Design for testability of Embedded integrated operational amplifiers -- Vérification des interfaces bioélectroniques des systèmes implantables -- Monitorin the electrode and lead failures in implanted microstimulators and sensors -- Capteurs de température intégrés pour la vérification de l'état thermique des puces dédiées -- Built-in temperature sensors for on-line thermal monitoring of microelectronic structures -- Un protocole de communication fiable pour la programmation et la télémétrie des système implantables -- A reliable communication protoco for externally controlled biomedical implanted devices

    Custom Integrated Circuits

    Get PDF
    Contains reports on six research projects.U.S. Air Force - Office of Scientific Research (Grant AFOSR-86-0164)U.S. Navy - Office of Naval Research (Contract N00014-80-C-0622)National Science Foundation (Grant ECS-83-10941

    DeSyRe: On-demand system reliability

    Get PDF
    The DeSyRe project builds on-demand adaptive and reliable Systems-on-Chips (SoCs). As fabrication technology scales down, chips are becoming less reliable, thereby incurring increased power and performance costs for fault tolerance. To make matters worse, power density is becoming a significant limiting factor in SoC design, in general. In the face of such changes in the technological landscape, current solutions for fault tolerance are expected to introduce excessive overheads in future systems. Moreover, attempting to design and manufacture a totally defect-/fault-free system, would impact heavily, even prohibitively, the design, manufacturing, and testing costs, as well as the system performance and power consumption. In this context, DeSyRe delivers a new generation of systems that are reliable by design at well-balanced power, performance, and design costs. In our attempt to reduce the overheads of fault-tolerance, only a small fraction of the chip is built to be fault-free. This fault-free part is then employed to manage the remaining fault-prone resources of the SoC. The DeSyRe framework is applied to two medical systems with high safety requirements (measured using the IEC 61508 functional safety standard) and tight power and performance constraints. (C) 2013 Elsevier B.V. All rights reserved
    • …
    corecore