645 research outputs found
Home-based rehabilitation of the shoulder using auxiliary systems and artificial intelligence: an overview
Advancements in modern medicine have bolstered the usage of home-based rehabilitation services for patients, particularly those recovering from diseases or conditions that necessitate a structured rehabilitation process. Understanding the technological factors that can influence the efficacy of home-based rehabilitation is crucial for optimizing patient outcomes. As technologies continue to evolve rapidly, it is imperative to document the current state of the art and elucidate the key features of the hardware and software employed in these rehabilitation systems. This narrative review aims to provide a summary of the modern technological trends and advancements in home-based shoulder rehabilitation scenarios. It specifically focuses on wearable devices, robots, exoskeletons, machine learning, virtual and augmented reality, and serious games. Through an in-depth analysis of existing literature and research, this review presents the state of the art in home-based rehabilitation systems, highlighting their strengths and limitations. Furthermore, this review proposes hypotheses and potential directions for future upgrades and enhancements in these technologies. By exploring the integration of these technologies into home-based rehabilitation, this review aims to shed light on the current landscape and offer insights into the future possibilities for improving patient outcomes and optimizing the effectiveness of home-based rehabilitation programs.info:eu-repo/semantics/publishedVersio
Physical Diagnosis and Rehabilitation Technologies
The book focuses on the diagnosis, evaluation, and assistance of gait disorders; all the papers have been contributed by research groups related to assistive robotics, instrumentations, and augmentative devices
Instrumentation and validation of a robotic cane for transportation and fall prevention in patients with affected mobility
Dissertação de mestrado integrado em Engenharia Física, (especialização em Dispositivos, Microssistemas e Nanotecnologias)O ato de andar é conhecido por ser a forma primitiva de locomoção do ser humano, sendo que este
traz muitos benefícios que motivam um estilo de vida saudável e ativo. No entanto, há condições de saúde
que dificultam a realização da marcha, o que por consequência pode resultar num agravamento da saúde,
e adicionalmente, levar a um maior risco de quedas. Nesse sentido, o desenvolvimento de um sistema de
deteção e prevenção de quedas, integrado num dispositivo auxiliar de marcha, seria essencial para reduzir
estes eventos de quedas e melhorar a qualidade de vida das pessoas. Para ultrapassar estas necessidades
e limitações, esta dissertação tem como objetivo validar e instrumentar uma bengala robótica, denominada
Anti-fall Robotic Cane (ARCane), concebida para incorporar um sistema de deteção de quedas e um
mecanismo de atuação que possibilite a prevenção de quedas, ao mesmo tempo que assiste a marcha.
Para esse fim, foi realizada uma revisão do estado da arte em bengalas robóticas para adquirir um
conhecimento amplo e aprofundado dos componentes, mecanismos e estratégias utilizadas, bem como os
protocolos experimentais, principais resultados, limitações e desafios em dispositivos existentes.
Numa primeira fase, foi estipulado o objetivo de: (i) adaptar a missão do produto; (ii) estudar as
necessidades do consumidor; e (iii) atualizar as especificações alvo da ARCane, continuação do trabalho de
equipa, para obter um produto com design e engenharia compatível com o mercado. Foi depois estabelecida
a arquitetura de hardware e discutidos os componentes a ser instrumentados na ARCane. Em seguida foram
realizados testes de interoperabilidade a fim de validar o funcionamento singular e coletivo dos componentes.
Relativamente ao controlo de movimento, foi desenvolvido um sistema inovador, de baixo custo e
intuitivo, capaz de detetar a intenção do movimento e de reconhecer as fases da marcha do utilizador. Esta
implementação foi validada com seis voluntários saudáveis que realizaram testes de marcha com a ARCane
para testar sua operabilidade num ambiente de contexto real. Obteve-se uma precisão de 97% e de 90% em
relação à deteção da intenção de movimento e ao reconhecimento da fase da marcha do utilizador.
Por fim, foi projetado um método de deteção de quedas e mecanismo de prevenção de quedas para
futura implementação na ARCane. Foi ainda proposta uma melhoria do método de deteção de quedas, de
modo a superar as limitações associadas, bem como a proposta de dispositivos de deteção a serem
implementados na ARCane para obter um sistema completo de deteção de quedas.The act of walking is known to be the primitive form of the human being, and it brings many benefits
that motivate a healthy and active lifestyle. However, there are health conditions that make walking difficult,
which, consequently, can result in worse health and, in addition, lead to a greater risk of falls. Thus, the
development of a fall detection and prevention system integrated with a walking aid would be essential to
reduce these fall events and improve people quality of life. To overcome these needs and limitations, this
dissertation aims to validate and instrument a cane-type robot, called Anti-fall Robotic Cane (ARCane),
designed to incorporate a fall detection system and an actuation mechanism that allow the prevention of
falls, while assisting the gait. Therefore, a State-of-the-Art review concerning robotic canes was carried out to
acquire a broad and in-depth knowledge of the used components, mechanisms and strategies, as well as
the experimental protocols, main results, limitations and challenges on existing devices.
On a first stage, it was set an objective to (i) enhance the product's mission statement; (ii) study the
consumer needs; and (iii) update the target specifications of the ARCane, extending teamwork, to obtain a
product with a market-compatible design and engineering that meets the needs and desires of the ARCane
users. It was then established the hardware architecture of the ARCane and discussed the electronic
components that will instrument the control, sensory, actuator and power units, being afterwards subjected
to interoperability tests to validate the singular and collective functioning of cane components altogether.
Regarding the motion control of robotic canes, an innovative, cost-effective and intuitive motion
control system was developed, providing user movement intention recognition, and identification of the user's
gait phases. This implementation was validated with six healthy volunteers who carried out gait trials with
the ARCane, in order to test its operability in a real context environment. An accuracy of 97% was achieved
for user motion intention recognition and 90% for user gait phase recognition, using the proposed motion
control system.
Finally, it was idealized a fall detection method and fall prevention mechanism for a future
implementation in the ARCane, based on methods applied to robotic canes in the literature. It was also
proposed an improvement of the fall detection method in order to overcome its associated limitations, as
well as detection devices to be implemented into the ARCane to achieve a complete fall detection system
Open electronics for medical devices: State-of-art and unique advantages
A wide range of medical devices have significant electronic components. Compared to open-source medical software, open (and open-source) electronic hardware has been less published in peer-reviewed literature. In this review, we explore the developments, significance, and advantages of using open platform electronic hardware for medical devices. Open hardware electronics platforms offer not just shorter development times, reduced costs, and customization; they also offer a key potential advantage which current commercial medical devices lack—seamless data sharing for machine learning and artificial intelligence. We explore how various electronic platforms such as microcontrollers, single board computers, field programmable gate arrays, development boards, and integrated circuits have been used by researchers to design medical devices. Researchers interested in designing low cost, customizable, and innovative medical devices can find references to various easily available electronic components as well as design methodologies to integrate those components for a successful design
Fiber Bragg Gratings as e-Health Enablers: An Overview for Gait Analysis Applications
Nowadays, the fast advances in sensing technologies and ubiquitous wireless networking are reflected in medical practice. It provides new healthcare advantages under the scope of e-Health applications, enhancing life quality of citizens. The increase of life expectancy of current population comes with its challenges and growing health risks, which include locomotive problems. Such impairments and its rehabilitation require a close monitoring and continuous evaluation, which add financial burdens on an already overloaded healthcare system. Analysis of body movements and gait pattern can help in the rehabilitation of such problems. These monitoring systems should be noninvasive and comfortable, in order to not jeopardize the mobility and the day-to-day activities of citizens. The use of fiber Bragg gratings (FBGs) as e-Health enablers has presented itself as a new topic to be investigated, exploiting the FBGs’ advantages over its electronic counterparts. Although gait analysis has been widely assessed, the use of FBGs in biomechanics and rehabilitation is recent, with a wide field of applications. This chapter provides a review of the application of FBGs for gait analysis monitoring, namely its use in topics such as the monitoring of plantar pressure, angle, and torsion and its integration in rehabilitation exoskeletons and for prosthetic control
- …