8,466 research outputs found

    Aptamers and Their Biological Applications

    Get PDF
    Recently, aptamers have attracted the attention of many scientists, because they not only have all of the advantages of antibodies, but also have unique merits, such as thermal stability, low cost, and unlimited applications. In this review, we present the reasons why aptamers are known as alternatives to antibodies. Furthermore, several types of in vitro selection processes, including nitrocellulose membrane filtration, affinity chromatography, magnetic bead, and capillary electrophoresis-based selection methods, are explained in detail. We also introduce various applications of aptamers for the diagnosis of diseases and detection of small molecules. Numerous analytical techniques, such as electrochemical, colorimetric, optical, and mass-sensitive methods, can be utilized to detect targets, due to convenient modifications and the stability of aptamers. Finally, several medical and analytical applications of aptamers are presented. In summary, aptamers are promising materials for diverse areas, not just as alternatives to antibodies, but as the core components of medical and analytical equipment

    Aptamer-based therapeutics and their potential in radiopharmaceutical design

    Get PDF
    Aptamers, short, single stranded oligonucleotide entities, have been developed in the past 15 years against a plethora of targets and for a variety of applications. These range from inhibition of receptors and enzymes to the identification of small molecules in sensor applications, and from the development of targeted therapeutic to the design of novel diagnostic and imaging agents. Furthermore, aptamers have been designed for targets that cover a wide range of diseases, from HIV to tropical diseases, cancer and inflammation. Their easy development and flexibility of use and manipulation, offers further potential. In this paper we review their selection and consider some of the recent applications of aptamers in the design of radiopharmaceuticals for the targeted radiotherapy and medical imaging of disease

    A new lab-on-chip transmitter for the detection of proteins using RNA aptamers

    Get PDF
    A new RNA aptamer based affinity biosensor for CReactive Protein (CRP), a risk marker for cardiovascular disease was developed using interdigitated capacitor (IDC), integrated in Voltage Controlled Oscillator (VCO) and output signal is amplified using Single Stage Power Amplifier (PA) for transmitting signal to receiver at Industrial, Scientific and Medical (ISM) band. The Lab-on-Chip transmitter design includes IDC, VCO and PA. The design was implemented in IHP 0.25μm SiGe BiCMOS process; post-CMOS process was utilized to increase the sensitivity of biosensor. The CRP was incubated between or on interdigitated electrodes and the changes in capacitance of IDC occurred. In blank measurements, the oscillation frequency was 2.464GHz whereas after RNA aptamers were immobilized on open aluminum areas of IDC and followed by binding reaction processed with 500pg/ml CRP solution, the capacitance shifted to 2.428GHz. Phase noise is changed from -114.3dBc/Hz to -116.5dBc/Hz

    Evaluating DFHBI-responsive RNA light-up aptamers as fluorescent reporters for gene expression

    Get PDF
    Protein-based fluorescent reporters have been widely used to characterize and localize biological processes in living cells. However, these reporters may have certain drawbacks for some applications, such as transcription-based studies or biological interactions with fast dynamics. In this context, RNA nanotechnology has emerged as a promising alternative, suggesting the use of functional RNA molecules as transcriptional fluorescent reporters. RNA-based aptamers can bind to nonfluorescent small molecules to activate their fluorescence. However, their performance as reporters of gene expression in living cells has not been fully characterized, unlike protein-based reporters. Here, we investigate the performance of three RNA light-up aptamers─F30-2xdBroccoli, tRNA-Spinach, and Tornado Broccoli─as fluorescent reporters for gene expression in Escherichia coli and compare them to a protein reporter. We examine the activation range and effect on the cell growth of RNA light-up aptamers in time-course experiments and demonstrate that these aptamers are suitable transcriptional reporters over time. Using flow cytometry, we compare the variability at the single-cell level caused by the RNA fluorescent reporters and protein-based reporters. We found that the expression of RNA light-up aptamers produced higher variability in a population than that of their protein counterpart. Finally, we compare the dynamical behavior of these RNA light-up aptamers and protein-based reporters. We observed that RNA light-up aptamers might offer faster dynamics compared to a fluorescent protein in E. coli. The implementation of these transcriptional reporters may facilitate transcription-based studies, gain further insights into transcriptional processes, and expand the implementation of RNA-based circuits in bacterial cells

    Programmable biomaterials for dynamic and responsive drug delivery

    Get PDF
    Biomaterials are continually being designed that enable new methods for interacting dynamically with cell and tissues, in turn unlocking new capabilities in areas ranging from drug delivery to regenerative medicine. In this review, we explore some of the recent advances being made in regards to programming biomaterials for improved drug delivery, with a focus on cancer and infection. We begin by explaining several of the underlying concepts that are being used to design this new wave of drug delivery vehicles, followed by examining recent materials systems that are able to coordinate the temporal delivery of multiple therapeutics, dynamically respond to changing tissue environments, and reprogram their bioactivity over time

    Aptamers for pharmaceuticals and their application in environmental analytics

    Get PDF
    Aptamers are single-stranded DNA or RNA oligonucleotides, which are able to bind with high affinity and specificity to their target. This property is used for a multitude of applications, for instance as molecular recognition elements in biosensors and other assays. Biosensor application of aptamers offers the possibility for fast and easy detection of environmental relevant substances. Pharmaceutical residues, deriving from human or animal medical treatment, are found in surface, ground, and drinking water. At least the whole range of frequently administered drugs can be detected in noticeable concentrations. Biosensors and assays based on aptamers as specific recognition elements are very convenient for this application because aptamer development is possible for toxic targets. Commonly used biological receptors for biosensors like enzymes or antibodies are mostly unavailable for the detection of pharmaceuticals. This review describes the research activities of aptamer and sensor developments for pharmaceutical detection, with focus on environmental applications

    Electrochemical Aptasensor for Detection of Dopamine

    Get PDF
    This work presents a proof of concept of a novel, simple, and sensitive method of detection of dopamine, a neurotransmitter within the human brain. We propose a simple electrochemical method for the detection of dopamine using a dopamine-specific aptamer labeled with an electrochemically active ferrocene tag. Aptamers immobilized on the surface of gold screen-printed gold electrodes via thiol groups can change their secondary structure by wrapping around the target molecule. As a result, the ferrocene labels move closer to the electrode surface and subsequently increase the electron transfer. The cyclic voltammograms and impedance spectra recorded on electrodes in buffer solutions containing different concentration of dopamine showed, respectively, the increase in both the anodic and cathodic currents and decrease in the double layer resistance upon increasing the concentration of dopamine from 0.1 to 10 nM L-1. The high affinity of aptamer-dopamine binding (KD ≈ 5 nM) was found by the analysis of the binding kinetics. The occurrence of aptamer-dopamine binding was directly confirmed with spectroscopic ellipsometry measurements
    corecore