630 research outputs found

    Faults Detection for Power Systems

    Get PDF
    Non

    Advances in Sensors and Sensing for Technical Condition Assessment and NDT

    Get PDF
    The adequate assessment of key apparatus conditions is a hot topic in all branches of industry. Various online and offline diagnostic methods are widely applied to provide early detections of any abnormality in exploitation. Furthermore, different sensors may also be applied to capture selected physical quantities that may be used to indicate the type of potential fault. The essential steps of the signal analysis regarding the technical condition assessment process may be listed as: signal measurement (using relevant sensors), processing, modelling, and classification. In the Special Issue entitled “Advances in Sensors and Sensing for Technical Condition Assessment and NDT”, we present the latest research in various areas of technology

    Classification and localization of electromagnetic and ultrasonic pulsed emitters

    Get PDF
    Mención Internacional en el título de doctorThe localization of radiative sources is very important in many fields of work such as: sonar, radar and underwater radar, indoor localization in wireless networks, earthquake epicenter localization, defective assets localization in electrical facilities and so forth. In the process of locating radiative sources exist many issues which can provoke errors in the localization. The signals acquired may belong to different sources or they can be mixed with environmental noise, then, their separation before using localization algorithms is of great interest to be efficient and accurate in the computational process. Furthermore, the geometry and radiation characteristics of the receivers, the nature of the signal or their measuring process may cause deviations in the signal onset calculus and therefore the source localization could be displaced from the actual position. In this thesis, there are three kinds of algorithms to undertake three steps in the emitter localization: signal separation, onset and time delay estimation of the signals and source localization. For each step, in order to reduce the error in the localization, several algorithms are analyzed and compared in each application, to choose the most reliable. As the first step, to separate different kinds of signals is of interest to facilitate further processing. In this thesis, different optimization techniques are presented over the power ratio (PR) maps method. The PR uses a selective spectral signal characterization to extract the features of the analyzed signals. The technique identifies automatically the most representative frequency bands which report a great separation of the different kinds of signals in the PR map. After separating and selecting the signals, it is of interest to compare the algorithms to calculate the onset and time delay of the pulsed signals to know their performance because the time variables are inputs to the most common triangulation algorithms to locate radiative and ultrasonic sources. An overview of the algorithms used to estimate the time of flight (ToF) and time differences of arrival (TDoA) of pulsed signals is done in this thesis. In the comparison, there is also a new algorithm based on statics of high order, which is proposed in this thesis. The survey of their performance is done applied to muscle deep estimation, localization in one dimension (1D), and for the localization of emitters in three dimensions (3D). The results show how the presented algorithm yields great results. As the last step in the radiative source localization, the formulation and principle of work of both iterative and non-iterative triangulation algorithms are presented. A new algorithm is presented as a combination of two already existing improving their performance when working alone. All the algorithms, the proposed and the previous which already exist, are compared in terms of accuracy and computational time. The proposed algorithm reports good results in terms of accuracy and it is one of the fastest in computational time. Once the localization is achieved, it is of great interest to understand how the errors in the determination of the onset of the signals are propagated in the emitter localization. The triangulation algorithms estimate the radiative source position using time variables as inputs: ToF, TDoA or pseudo time of flight (pToF) and the receiver positions. The propagation of the errors in the time variables to the radiative source localization is done in two dimensions (2D) and 3D. New spherical diagrams have been created to represent the directions where the localization is more or less sensible to the errors. This study and their sphere diagrams are presented for several antenna layouts. Finally, how the errors in the positioning of the receivers are propagated to the emitter localization is analyzed. In this study, the effect in the propagation of both the relative distance from the receivers to the emitter and the direction between them has been characterized. The propagation of the error considering the direction is also represented in spherical diagrams. For a preferred direction identified in the spheres, the propagated error in the source localization has been quantified regarding both the source distance and the magnitude of the errors in the receivers positioning.Programa Oficial de Doctorado en Ingeniería Eléctrica, Electrónica y AutomáticaPresidente: Andrea Cavallini.- Secretario: José Antonio García Souto.- Vocal: Iliana Portugués Peter

    PD Source Location Utilizing Acoustic TDOA Signals in Power Transformer by Fuzzy Adaptive Particle Swarm Optimization

    Get PDF
    Acoustic Emission Partial discharge (AEPD) Location is one of the techniques utilized by many transformer manufacturers and power utility engineers in routine and critical situation for optimal operation of the electrical power system as well as further risk management and repair planning. The PD detection is not enough to take solution so identification of PD source is essential to restore apparatus condition. This work aim is to localize the defect geometrically by means of time difference of arrival signals in order to accurately locate PD source in the power transformer. The solution for this PD source location is acquired by making these nonlinear equations as optimization problem. In the present work, the fuzzy adaptive particle swarm optimization (FAPSO) for partial discharge (PD) source localization in power transformer is proposed. In this technique, the inertia weight is effectively regulated by using conditional IF-THEN statements to improve the global optimal solution and impairs the local convergence problem and improves the accuracy in estimating the PD source location. The simulation results reveals that PD location accuracy with minimum of maximum deviation error, absolute error and relative error is better when compared to other constant parameter intelligent methods which were reported in the literature

    Selected Papers from 2020 IEEE International Conference on High Voltage Engineering (ICHVE 2020)

    Get PDF
    The 2020 IEEE International Conference on High Voltage Engineering (ICHVE 2020) was held on 6–10 September 2020 in Beijing, China. The conference was organized by the Tsinghua University, China, and endorsed by the IEEE Dielectrics and Electrical Insulation Society. This conference has attracted a great deal of attention from researchers around the world in the field of high voltage engineering. The forum offered the opportunity to present the latest developments and different emerging challenges in high voltage engineering, including the topics of ultra-high voltage, smart grids, and insulating materials

    Acoustic power distribution techniques for wireless sensor networks

    Get PDF
    Recent advancements in wireless power transfer technologies can solve several residual problems concerning the maintenance of wireless sensor networks. Among these, air-based acoustic systems are still less exploited, with considerable potential for powering sensor nodes. This thesis aims to understand the significant parameters for acoustic power transfer in air, comprehend the losses, and quantify the limitations in terms of distance, alignment, frequency, and power transfer efficiency. This research outlines the basic concepts and equations overlooking sound wave propagation, system losses, and safety regulations to understand the prospects and limitations of acoustic power transfer. First, a theoretical model was established to define the diffraction and attenuation losses in the system. Different off-the-shelf transducers were experimentally investigated, showing that the FUS-40E transducer is most appropriate for this work. Subsequently, different load-matching techniques are analysed to identify the optimum method to deliver power. The analytical results were experimentally validated, and complex impedance matching increased the bandwidth from 1.5 to 4 and the power transfer efficiency from 0.02% to 0.43%. Subsequently, a detailed 3D profiling of the acoustic system in the far-field region was provided, analysing the receiver sensitivity to disturbances in separation distance, receiver orientation and alignment. The measured effects of misalignment between the transducers are provided as a design graph, correlating the output power as a function of separation distance, offset, loading methods and operating frequency. Finally, a two-stage wireless power network is designed, where energy packets are inductively delivered to a cluster of nodes by a recharge vehicle and later acoustically distributed to devices within the cluster. A novel dynamic recharge scheduling algorithm that combines weighted genetic clustering with nearest neighbour search is developed to jointly minimise vehicle travel distance and power transfer losses. The efficacy and performance of the algorithm are evaluated in simulation using experimentally derived traces that presented 90% throughput for large, dense networks.Open Acces

    Characterization of Power Transformer Frequency Response Signature using Finite Element Analysis

    Get PDF
    Power transformers are a vital link in electrical transmission and distribution networks. Monitoring and diagnostic techniques are essential to decrease maintenance and improve the reliability of the equipment.This research has developed a novel, versatile, reliable and robust technique for modelling high frequency power transformers. The purpose of this modelling is to enable engineers to conduct sensitivity analyses of FRA in the course of evaluating mechanical defects of power transformer windings. The importance of this new development is that it can be applied successfully to industry transformers of real geometries

    Modern Applications of Electrostatics and Dielectrics

    Get PDF
    Electrostatics and dielectric materials have important applications in modern society. As such, they require improved characteristics. More and more equipment needs to operate at high frequency, high voltage, high temperature, and other harsh conditions. This book presents an overview of modern applications of electrostatics and dielectrics as well as research progress in the field
    • …
    corecore