469 research outputs found

    Course Description

    Get PDF

    Surgical Subtask Automation for Intraluminal Procedures using Deep Reinforcement Learning

    Get PDF
    Intraluminal procedures have opened up a new sub-field of minimally invasive surgery that use flexible instruments to navigate through complex luminal structures of the body, resulting in reduced invasiveness and improved patient benefits. One of the major challenges in this field is the accurate and precise control of the instrument inside the human body. Robotics has emerged as a promising solution to this problem. However, to achieve successful robotic intraluminal interventions, the control of the instrument needs to be automated to a large extent. The thesis first examines the state-of-the-art in intraluminal surgical robotics and identifies the key challenges in this field, which include the need for safe and effective tool manipulation, and the ability to adapt to unexpected changes in the luminal environment. To address these challenges, the thesis proposes several levels of autonomy that enable the robotic system to perform individual subtasks autonomously, while still allowing the surgeon to retain overall control of the procedure. The approach facilitates the development of specialized algorithms such as Deep Reinforcement Learning (DRL) for subtasks like navigation and tissue manipulation to produce robust surgical gestures. Additionally, the thesis proposes a safety framework that provides formal guarantees to prevent risky actions. The presented approaches are evaluated through a series of experiments using simulation and robotic platforms. The experiments demonstrate that subtask automation can improve the accuracy and efficiency of tool positioning and tissue manipulation, while also reducing the cognitive load on the surgeon. The results of this research have the potential to improve the reliability and safety of intraluminal surgical interventions, ultimately leading to better outcomes for patients and surgeons

    3D/4D printing of cellulose nanocrystals-based biomaterials: Additives for sustainable applications

    Get PDF
    Cellulose nanocrystals (CNCs) have gained significant attraction from both industrial and academic sectors, thanks to their biodegradability, non-toxicity, and renewability with remarkable mechanical characteristics. Desirable mechanical characteristics of CNCs include high stiffness, high strength, excellent flexibility, and large surface-to-volume ratio. Additionally, the mechanical properties of CNCs can be tailored through chemical modifications for high-end applications including tissue engineering, actuating, and biomedical. Modern manufacturing methods including 3D/4D printing are highly advantageous for developing sophisticated and intricate geometries. This review highlights the major developments of additive manufactured CNCs, which promote sustainable solutions across a wide range of applications. Additionally, this contribution also presents current challenges and future research directions of CNC-based composites developed through 3D/4D printing techniques for myriad engineering sectors including tissue engineering, wound healing, wearable electronics, robotics, and anti-counterfeiting applications. Overall, this review will greatly help research scientists from chemistry, materials, biomedicine, and other disciplines to comprehend the underlying principles, mechanical properties, and applications of additively manufactured CNC-based structures

    Bio-Inspired Soft Artificial Muscles for Robotic and Healthcare Applications

    Full text link
    Soft robotics and soft artificial muscles have emerged as prolific research areas and have gained substantial traction over the last two decades. There is a large paradigm shift of research interests in soft artificial muscles for robotic and medical applications due to their soft, flexible and compliant characteristics compared to rigid actuators. Soft artificial muscles provide safe human-machine interaction, thus promoting their implementation in medical fields such as wearable assistive devices, haptic devices, soft surgical instruments and cardiac compression devices. Depending on the structure and material composition, soft artificial muscles can be controlled with various excitation sources, including electricity, magnetic fields, temperature and pressure. Pressure-driven artificial muscles are among the most popular soft actuators due to their fast response, high exertion force and energy efficiency. Although significant progress has been made, challenges remain for a new type of artificial muscle that is easy to manufacture, flexible, multifunctional and has a high length-to-diameter ratio. Inspired by human muscles, this thesis proposes a soft, scalable, flexible, multifunctional, responsive, and high aspect ratio hydraulic filament artificial muscle (HFAM) for robotic and medical applications. The HFAM consists of a silicone tube inserted inside a coil spring, which expands longitudinally when receiving positive hydraulic pressure. This simple fabrication method enables low-cost and mass production of a wide range of product sizes and materials. This thesis investigates the characteristics of the proposed HFAM and two implementations, as a wearable soft robotic glove to aid in grasping objects, and as a smart surgical suture for perforation closure. Multiple HFAMs are also combined by twisting and braiding techniques to enhance their performance. In addition, smart textiles are created from HFAMs using traditional knitting and weaving techniques for shape-programmable structures, shape-morphing soft robots and smart compression devices for massage therapy. Finally, a proof-of-concept robotic cardiac compression device is developed by arranging HFAMs in a special configuration to assist in heart failure treatment. Overall this fundamental work contributes to the development of soft artificial muscle technologies and paves the way for future comprehensive studies to develop HFAMs for specific medical and robotic requirements

    Annotated Bibliography: Anticipation

    Get PDF

    1-D broadside-radiating leaky-wave antenna based on a numerically synthesized impedance surface

    Get PDF
    A newly-developed deterministic numerical technique for the automated design of metasurface antennas is applied here for the first time to the design of a 1-D printed Leaky-Wave Antenna (LWA) for broadside radiation. The surface impedance synthesis process does not require any a priori knowledge on the impedance pattern, and starts from a mask constraint on the desired far-field and practical bounds on the unit cell impedance values. The designed reactance surface for broadside radiation exhibits a non conventional patterning; this highlights the merit of using an automated design process for a design well known to be challenging for analytical methods. The antenna is physically implemented with an array of metal strips with varying gap widths and simulation results show very good agreement with the predicted performance

    Soft Robot-Assisted Minimally Invasive Surgery and Interventions: Advances and Outlook

    Get PDF
    Since the emergence of soft robotics around two decades ago, research interest in the field has escalated at a pace. It is fuelled by the industry's appreciation of the wide range of soft materials available that can be used to create highly dexterous robots with adaptability characteristics far beyond that which can be achieved with rigid component devices. The ability, inherent in soft robots, to compliantly adapt to the environment, has significantly sparked interest from the surgical robotics community. This article provides an in-depth overview of recent progress and outlines the remaining challenges in the development of soft robotics for minimally invasive surgery

    Beam scanning by liquid-crystal biasing in a modified SIW structure

    Get PDF
    A fixed-frequency beam-scanning 1D antenna based on Liquid Crystals (LCs) is designed for application in 2D scanning with lateral alignment. The 2D array environment imposes full decoupling of adjacent 1D antennas, which often conflicts with the LC requirement of DC biasing: the proposed design accommodates both. The LC medium is placed inside a Substrate Integrated Waveguide (SIW) modified to work as a Groove Gap Waveguide, with radiating slots etched on the upper broad wall, that radiates as a Leaky-Wave Antenna (LWA). This allows effective application of the DC bias voltage needed for tuning the LCs. At the same time, the RF field remains laterally confined, enabling the possibility to lay several antennas in parallel and achieve 2D beam scanning. The design is validated by simulation employing the actual properties of a commercial LC medium
    corecore