15,986 research outputs found

    Harmonic chirp imaging method for ultrasound contrast agent

    Get PDF
    Coded excitation is currently used in medical ultrasound to increase signal-to-noise ratio (SNR) and penetration depth. We propose a chirp excitation method\ud for contrast agents using the second harmonic component of the response. This method is based on a compression filter that selectively compresses and extracts the second harmonic component from the received echo signal. Simulations have shown a clear increase in response for chirp excitation\ud over pulse excitation with the same peak amplitude. This was confirmed by two-dimensional (2-D) optical observations of bubble response with a fast framing camera. To evaluate the harmonic compression method, we applied it to\ud simulated bubble echoes, to measured propagation harmonics, and to B-mode scans of a flow phantom and compared it to regular pulse excitation imaging. An increase of approximately 10 dB in SNR was found for chirp excitation. The\ud compression method was found to perform well in terms of resolution. Axial resolution was in all cases within 10% of the axial resolution from pulse excitation. Range side-lobe levels were 30 dB below the main lobe for the simulated bubble echoes and measured propagation harmonics. However,\ud side-lobes were visible in the B-mode contrast images

    Compressive Hyperspectral Imaging Using Progressive Total Variation

    Get PDF
    Compressed Sensing (CS) is suitable for remote acquisition of hyperspectral images for earth observation, since it could exploit the strong spatial and spectral correlations, llowing to simplify the architecture of the onboard sensors. Solutions proposed so far tend to decouple spatial and spectral dimensions to reduce the complexity of the reconstruction, not taking into account that onboard sensors progressively acquire spectral rows rather than acquiring spectral channels. For this reason, we propose a novel progressive CS architecture based on separate sensing of spectral rows and joint reconstruction employing Total Variation. Experimental results run on raw AVIRIS and AIRS images confirm the validity of the proposed system.Comment: To be published on ICASSP 2014 proceeding

    Breast compression – An exploration of problem solving and decision-making in mammography

    Get PDF
    Objective: Breast compression decreases radiation dose and reduces potential for motion and geometric unsharpness, yet there is variability in applied compression force within and between some centres. This article explores the problem solving process applied to the application of breast compression force from the mammography practitioners' perspective. Methods: A qualitative analysis was undertaken using an existing full data set of transcribed qualitative data collected in a phenomenological study of mammography practitioner values, behaviours and beliefs. The data emerged from focus groups conducted at six NHS breast screening centres in England (participant n = 41), and semi-structured interviews with mammography educators (n = 6). A researcher followed a thematic content analysis process to extract data related to mammography compression problem solving, developing a series of categories, themes and sub-themes. Emerging themes were then peer-validated by two other researchers, and developed into a model of practice. Results: Seven consecutive stages contributed towards compression force problem solving: assessing the request; first impressions; explanations and consent; handling the breast and positioning; applying compression force; final adjustments; feedback. The model captures information gathering, problem framing, problem solving and decision making which inform an ‘ideal’ compression scenario. Behavioural problem solving, heuristics and intuitive decision making are reflected within this model. Conclusion: The application of compression should no longer be considered as one single task within mammography, but is now recognised as a seven stage problem solving continuum. This continuum model is the first to be applied to mammography, and is adaptable and transferable to other radiography practice settings
    corecore