101 research outputs found

    Advanced image reconstruction in parallel magnetic resonance imaging : constraints and solutions.

    Get PDF
    Thesis (Ph. D.)--Harvard-MIT Division of Health Sciences and Technology, 2005.Includes bibliographical references.Imaging speed is a crucial consideration for magnetic resonance imaging (MRI). The speed of conventional MRI is limited by hardware performance and physiological safety measures. "Parallel" MRI is a new technique that circumvents these limitations by utilizing arrays of radiofrequency detector coils to acquire data in parallel, thereby enabling still higher imaging speeds. In parallel MRI, coil arrays are used to accomplish part of the spatial encoding that was traditionally performed by magnetic field gradients alone. MR signal data acquired with coil arrays are spatially encoded with the distinct reception patterns of the individual coil elements. T[he quality of parallel MR images is dictated by the accuracy and efficiency of an image reconstruction (decoding) strategy. This thesis formulates the spatial encoding and decoding of parallel MRI as a generalized linear inverse problem. Under this linear algebraic framework, theoretical and empirical limits on the performance of parallel MR image reconstructions are characterized, and solutions are proposed to facilitate routine clinical and research applications. Each research study presented in this thesis addresses one or more elements in the inverse problem, and the studies are collectively arranged to reflect three progressive stages in solving the inverse problem: 1) determining the encoding matrix, 2) computing a matrix inverse, 3) characterizing the error involved. First, a self-calibrating strategy is proposed which uses non-Cartesian trajectories to automatically determine coil sensitivities without the need of an external scan or modification of data acquisition, guaranteeing an accurate formulation of the encoding matrix.(cont.) Second, two matrix inversion strategies are presented which, respectively, exploit physical properties of coil encoding and the phase information of the magnetization. While the former allows stable and distributable matrix inversion using the k-space locality principle, the latter integrates parallel image reconstruction with conjugate symmetry. Third, a numerical strategy is presented for computing noise statistics of parallel MRI techniques which involve magnitude image combination, enabling quantitative image comparison. In addition, fundamental limits on the performance of parallel image reconstruction are derived using the Cramer-Rao bounds. Lastly, the practical applications of techniques developed in this thesis are demonstrated by a case study in improved coronary angiography.Ph.D

    Echocardiography

    Get PDF
    The book "Echocardiography - New Techniques" brings worldwide contributions from highly acclaimed clinical and imaging science investigators, and representatives from academic medical centers. Each chapter is designed and written to be accessible to those with a basic knowledge of echocardiography. Additionally, the chapters are meant to be stimulating and educational to the experts and investigators in the field of echocardiography. This book is aimed primarily at cardiology fellows on their basic echocardiography rotation, fellows in general internal medicine, radiology and emergency medicine, and experts in the arena of echocardiography. Over the last few decades, the rate of technological advancements has developed dramatically, resulting in new techniques and improved echocardiographic imaging. The authors of this book focused on presenting the most advanced techniques useful in today's research and in daily clinical practice. These advanced techniques are utilized in the detection of different cardiac pathologies in patients, in contributing to their clinical decision, as well as follow-up and outcome predictions. In addition to the advanced techniques covered, this book expounds upon several special pathologies with respect to the functions of echocardiography

    Development of a silicon photomultiplier based innovative and low cost positron emission tomography scanner.

    Get PDF
    The Silicon Photomultiplier (SiPM) is a state-of-the-art semiconductor photodetector consisting of a high density matrix (up to 104) of independent pixels of micro-metric dimension (from 10 \u3bcm to 100 \u3bcm) which form a macroscopic unit of 1 to 6 mm2 area. Each pixel is a single-photon avalanche diode operated with a bias voltage of a few volts above the breakdown voltage. When a charge carrier is generated in a pixel by an incoming photon or a thermal effect, a Geiger discharge confined to that pixel is initiated and an intrinsic gain of about 106 is obtained. The output signal of a pixel is the same regardless of the number of interacting photons and provide only a binary information. Since the pixels are arranged on a common Silicon substrate and are connected in parallel to the same readout line, the SiPM combined output response corresponds to the sum of all fired pixel currents. As a result, the SiPM as a whole is an analogue detector, which can measure the incoming light intensity. Nowadays a great number of companies are investing increasing efforts in SiPM detector performances and high quality mass production. SiPMs are in rapid evolution and benefit from the tremendous development of the Silicon technology in terms of cost production, design flexibility and performances. They have reached a high single photon detection sensitivity and photon detection efficiency, an excellent time resolution, an extended dynamic range. They require a low bias voltage and have a low power consumption, they are very compact, robust, flexible and cheap. Considering also their intrinsic insensitivity to magnetic field they result to have an extremely high potential in fundamental and applied science (particle and nuclear physics, astrophysics, biology, environmental science and nuclear medicine) and industry. The SiPM performances are influenced by some effects, as saturation, afterpulsing and crosstalk, which lead to an inherent non-proportional response with respect to the number of incident photons. Consequently, it is not trivial to relate the measured electronic signal to the corresponding light intensity. Since for most applications it is desirable to qualify the SiPM response (i.e in order to properly design a detector for a given application, perform corrections on measurements or on energy spectra, calibrate a SiPM for low light measurements, predict detector performance) the implementation of characterization procedures plays a key role. The SiPM field of application that has been considered in this thesis is the Positron Emission Tomography (PET). PET represents the most advanced in-vivo nuclear imaging modality: it provides functional information of the physiological and molecular processes of organs and tissues. Thanks to its diagnostic power, PET has a recognized superiority over all other imaging modalities in oncology, neurology and cardiology. SiPMs are usually successfully employed for the PET scanners because they allow the measurement of the Time Of Flight of the two coincidence photons to improve the signal to noise ratio of the reconstructed images. They also permit to perfectly combine the functional information with the anatomical one by inserting the PET scanner inside the Magnetic Resonance Imaging device. Recently, PET technology has also been applied to preclinical imaging to allow non invasive studies on small animals. The increasing demand for preclinical PET scanner is driven by the fact that small animals host a large number of human diseases. In-vivo imaging has the advantage to enable the measurement of the radiopharmaceutical distribution in the same animal for an extended period of time. As a result, PET represents a powerful research tool as it offers the possibility to study the abnormalities at the origin of a disease, understand its dynamics, evaluate the therapeutic response and develop new drugs and treatments. However, the cost and the complexity of the preclinical scanners are limiting factors for the spread of PET technology: 70-80% of small-animal PET is concentrated in academic or government research laboratories. The EasyPET concept proposed in this Thesis, protected under a patent filed by Aveiro University, aims to achieve a simple and affordable preclinical PET scanner. The innovative concept is based on a single pair of detector kept collinear during the whole data acquisition and a moving mechanism with two degrees of freedom to reproduce the functionalities of an entire PET ring. The main advantages are in terms of the reduction of the complexity and cost of the PET system. In addition the concept is bound to be robust against acollinear photoemission, scatter radiation and parallax error. The sensitivity is expected to represent a fragility due to the reduced geometrical acceptance. This drawback can be partially recovered by the possibility to accept Compton scattering events without introducing image degradation effects, thanks to the sensor alignment. A 2D imaging demonstrator has been realized in order to assess the EasyPET concept and its performance has been analyzed in this Thesis to verify the net balance between competing advantages and drawbacks. The demonstrator had a leading role in the outreach activity to promote the EasyPET concept and a significant outcome is represented by the new partners that recently joined the collaboration. The EasyPET has been licensed to Caen S.p.a. and, thanks to the participation of Nuclear Instruments to the electronic board re-designed, a new prototype has been realized with additional improvements concerning the mechanics and the control software. In this Thesis the prototype functionalities and performances are reported as a result of a commissioning procedure. The EasyPET will be commercialized by Caen S.p.a. as a product for the educational market and it will be addressed to high level didactic laboratories to show the operating principles and technology behind the PET imaging. The topics mentioned above will be examined in depth in the following Chapters according to the subsequent order. In Chapter 1 the Silicon Photomultiplier will be described in detail, from their operating principle to their main application fields passing through the advantages and the drawback effects connected with this type of sensor. Chapter 2 is dedicated to a SiPM standard characterization method based on the staircase and resolving power measurement. A more refined analysis involves the Multi-Photon spectrum, obtained by integrating the SiPM response to a light pulse. It exploits the SiPM single photon sensitivity and its photon number resolving capability to measure some of its properties of general interest for a multitude of potential applications, disentangling the features related to the statistics of the incident light. Chapter 3 reports another SiPM characterization method which implements a post-processing of the digitized SiPM waveforms with the aim of extracting a full picture of the sensor characteristics from a unique data-set. The procedure is very robust, effective and semi-automatic and suitable for sensors of various dimensions and produced by different vendors. Chapter 4 introduces the Positron Emission Tomography imaging: its principle, applications, related issues and state of the art of PET scanner will be explained. Chapter 5 deals with the preclinical PET, reporting the benefits and the technological challenges involved, the performance of the commercially available small animal PET scanners, the main applications and the frontier research in this field. In Chapter 6 the EasyPET concept is introduced. In particular, the basic idea behind the operating principle, the design layout and the image reconstruction will be illustrated and then assessed through the description and the performance analysis of the EasyPET proof of concept and demonstrator. The effect of the use of different sensor to improve the light collection and the coincidence detection efficiency, together with the analysis of the importance of the sensor and the crystal alignment will be reported in Chapter 7. The design, the functionalities and the commissioning of the EasyPET prototype addressed to the educational market will be defined in Chapter 8. Finally, Chapter 9 contains a summary of the conclusions and an outlook of the future research studies

    Preclinical MRI of the Kidney

    Get PDF
    This Open Access volume provides readers with an open access protocol collection and wide-ranging recommendations for preclinical renal MRI used in translational research. The chapters in this book are interdisciplinary in nature and bridge the gaps between physics, physiology, and medicine. They are designed to enhance training in renal MRI sciences and improve the reproducibility of renal imaging research. Chapters provide guidance for exploring, using and developing small animal renal MRI in your laboratory as a unique tool for advanced in vivo phenotyping, diagnostic imaging, and research into potential new therapies. Written in the highly successful Methods in Molecular Biology series format, chapters include introductions to their respective topics, lists of the necessary materials and reagents, step-by-step, readily reproducible laboratory protocols, and tips on troubleshooting and avoiding known pitfalls. Cutting-edge and thorough, Preclinical MRI of the Kidney: Methods and Protocols is a valuable resource and will be of importance to anyone interested in the preclinical aspect of renal and cardiorenal diseases in the fields of physiology, nephrology, radiology, and cardiology. This publication is based upon work from COST Action PARENCHIMA, supported by European Cooperation in Science and Technology (COST). COST (www.cost.eu) is a funding agency for research and innovation networks. COST Actions help connect research initiatives across Europe and enable scientists to grow their ideas by sharing them with their peers. This boosts their research, career and innovation. PARENCHIMA (renalmri.org) is a community-driven Action in the COST program of the European Union, which unites more than 200 experts in renal MRI from 30 countries with the aim to improve the reproducibility and standardization of renal MRI biomarkers
    • …
    corecore