576 research outputs found

    Design and performance of a compact and stationary microSPECT system

    Get PDF
    Purpose: Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial resolutions range from 0.58 to 0.76 mm while peak sensitivities vary from 0.06% to 0.4%. While pushing the limits of performance is of major importance, the authors believe that there is a need for smaller and less complex systems that bring along a reduced cost. While low footprint and low-cost systems can make microSPECT available to more researchers, the ease of operation and calibration and low maintenance cost are additional factors that can facilitate the use of microSPECT in molecular imaging. In this paper, the authors simulate the performance of a microSPECT imager that combines high space-bandwidth detectors and pinholes with truncated projection, resulting in a small and stationary system. Methods: A system optimization algorithm is used to determine the optimal SPECT systems, given our high resolutions detectors and a fixed field-of-view. These optimal system geometries are then used to simulate a Defrise disk phantom and a hot rod phantom. Finally, a MOBY mouse phantom, with realistic concentrations of Tc99m-tetrofosmin is simulated. Results: Results show that the authors can successfully reconstruct a Defrise disk phantom of 24 mm in diameter without any rotating system components or translation of the object. Reconstructed spatial resolution is approximately 800 mu m while the peak sensitivity is 0.23%. Finally, the simulation of the MOBY mouse phantom shows that the authors can accurately reconstruct mouse images. Conclusions: These results show that pinholes with truncated projections can be used in small magnification or minification mode to obtain a compact and stationary microSPECT system. The authors showed that they can reach state-of-the-art system performance and can successfully reconstruct images with realistic noise levels in a preclinical context. Such a system can be useful for dynamic SPECT imaging. 2013 American Association of Physicists in Medicine

    The clinical utilities of multi-pinhole single photon emission computed tomography

    Get PDF
    Single photon emission computed tomography (SPECT) is an important imaging modality for various applications in nuclear medicine. The use of multi-pinhole (MPH) collimators can provide superior resolution-sensitivity trade-off when imaging small field-of-view compared to conventional parallel-hole and fan-beam collimators. Besides the very successful application in small animal imaging, there has been a resurgence of the use of MPH collimators for clinical cardiac and brain studies, as well as other small field-of-view applications. This article reviews the basic principles of MPH collimators and introduces currently available and proposed clinical MPH SPECT systems

    Studying Flow Close to an Interface by Total Internal Reflection Fluorescence Cross Correlation Spectroscopy: Quantitative Data Analysis

    Full text link
    Total Internal Reflection Fluorescence Cross Correlation Spectroscopy (TIR-FCCS) has recently (S. Yordanov et al., Optics Express 17, 21149 (2009)) been established as an experimental method to probe hydrodynamic flows near surfaces, on length scales of tens of nanometers. Its main advantage is that fluorescence only occurs for tracer particles close to the surface, thus resulting in high sensitivity. However, the measured correlation functions only provide rather indirect information about the flow parameters of interest, such as the shear rate and the slip length. In the present paper, we show how to combine detailed and fairly realistic theoretical modeling of the phenomena by Brownian Dynamics simulations with accurate measurements of the correlation functions, in order to establish a quantitative method to retrieve the flow properties from the experiments. Firstly, Brownian Dynamics is used to sample highly accurate correlation functions for a fixed set of model parameters. Secondly, these parameters are varied systematically by means of an importance-sampling Monte Carlo procedure in order to fit the experiments. This provides the optimum parameter values together with their statistical error bars. The approach is well suited for massively parallel computers, which allows us to do the data analysis within moderate computing times. The method is applied to flow near a hydrophilic surface, where the slip length is observed to be smaller than 10nm, and, within the limitations of the experiments and the model, indistinguishable from zero.Comment: 18 pages, 12 figure

    Design of a static full-ring multi-pinhole collimator for brain SPECT

    Get PDF
    In clinical practice, brain SPECT is mostly performed using a dual-head SPECT scanner with fan-beam or parallel-beam collimators rotating around the patient's head. The resolution of such a system is typically about 6-8 mm, which is rather poor to image the complex structures of the human brain. We developed a non-rotating multi-pinhole collimator for brain SPECT imaging with a resolution of 4 mm. A full-ring geometry allows for complete transaxial sampling. This enables the use of a stationary collimator. The collimator is a tungsten ring with two rows of pinholes. Each pinhole can individually be opened or closed with shutters. A sequence of shutter movements is performed to obtain an acquisition setup that simulates a rotational movement. The collimator is designed for the LaPET system (a PET detector ring made of 24 LaBr 3 detectors) and is optimized to maximize the system performance, resulting in a collimator radius of 145 mm and a pinhole diameter of 2 mm. This system has a sensitivity that is 4 times lower than a dual-head system with LEHR parallel-beam collimators. However, the resolution is 2 times better, a trade-off that is supported by Muehllehner [1]. Monte-Carlo simulated projections of a resolution phantom are successfully reconstructed and the resulting image shows that a resolution of 4 mm is indeed achieved

    Preclinical SPECT imaging based on compact collimators and high resolution scintillation detectors

    Get PDF

    SPECT imaging with rotating slat collimator

    Get PDF

    Stationary, MR-compatible brain SPECT imaging based on multi-pinhole collimators

    Get PDF

    Relevance of accurate Monte Carlo modeling in nuclear medical imaging

    Get PDF
    Monte Carlo techniques have become popular in different areas of medical physics with advantage of powerful computing systems. In particular, they have been extensively applied to simulate processes involving random behavior and to quantify physical parameters that are difficult or even impossible to calculate by experimental measurements. Recent nuclear medical imaging innovations such as single-photon emission computed tomography (SPECT), positron emission tomography (PET), and multiple emission tomography (MET) are ideal for Monte Carlo modeling techniques because of the stochastic nature of radiation emission, transport and detection processes. Factors which have contributed to the wider use include improved models of radiation transport processes, the practicality of application with the development of acceleration schemes and the improved speed of computers. This paper presents derivation and methodological basis for this approach and critically reviews their areas of application in nuclear imaging. An overview of existing simulation programs is provided and illustrated with examples of some useful features of such sophisticated tools in connection with common computing facilities and more powerful multiple-processor parallel processing systems. Current and future trends in the field are also discussed

    A versatile imaging system for in vivo small animal research

    Get PDF
    In vivo small animal imaging has become an essential technique for molecular biology studies. However, requirements of spatial resolution, sensitivity and image quality are quite challenging for the development of small-animal imaging systems. The capabilities of the system are also significant for carrying out small animal imaging in a wide range of biological studies. The goal of this dissertation is to develop a high-performance imaging system that can readily meet a wide range of requirements for a variety of small animal imaging applications. Several achievements have been made in order to fulfill this goal.;To supplement our system for parallel-hole single photon emission computed tomography (SPECT) based upon a 110 mm diameter circular detector, we have developed novel compact gamma cameras suitable for imaging an entire mouse. These gamma cameras facilitate multi-head (\u3e2) parallel-hole SPECT with the mouse in close proximity to the detector face in order to preserve spatial resolution. Each compact gamma cameras incorporates pixellated Nal(Tl) scintillators and a pair of Hamamatsu H8500 position sensitive photomultiplier tubes (PSPMTs). Two types of copper-beryllium parallel-hole collimators have been designed. These provide high-sensitivity imaging of I-125 or excellent spatial resolution over a range of object-detector distances. Both phantom and animal studies have demonstrated that these gamma cameras perform well for planar scintigraphy and parallel-hole SPECT of mice.;To further address the resolution limitations in parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have developed novel multipinhole helical SPECT based upon a 110 mm diameter circular detector equipped with a pixellated Nal(Tl) scintillator array. A brass collimator has been designed and produced containing five 1 mm diameter pinholes. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using this new imaging technique.;These studies in small-animal imaging have been applied to in vivo biological studies related to human health issues including studies of the thyroid and breast cancer. A re-evaluation study of potassium iodide blocking efficiency in radioiodine uptake in mice suggests that the FDA-recommended human dose of stable potassium iodide may not be sufficient to effectively protect the thyroid from radioiodine contamination. Another recent study has demonstrated that multipinhole helical SPECT can resolve the fine structure of the mouse thyroid using a relatively low dose (200 muCi). Another preclinical study has focused on breast tumor imaging using a compact gamma camera and an endogenous reporter gene. In that ongoing study, mammary tumors are imaged at different stages. Preliminary results indicate different functional patterns in the uptake of radiotracers and their potential relationship with other tumor parameters such as tumor size.;In summary, we have developed a versatile imaging system suitable for in vivo small animal research as evidenced by a variety of applications. The modular construction of this system will allow expansion and further development as new needs and new opportunities arise
    • …
    corecore