    Remote Navigation and Contact-Force Control of Radiofrequency Ablation Catheters

    Get PDF
    Atrial fibrillation (AF), the most common and clinically significant heart rhythm disorder, is characterized by rapid and irregular electrical activity in the upper chambers resulting in abnormal contractions. Radiofrequency (RF) cardiac catheter ablation is a minimally invasive curative treatment that aims to electrically correct signal pathways inside the atria to restore normal sinus rhythm. Successful catheter ablation requires the complete and permanent elimination of arrhythmogenic signals by delivering transmural RF ablation lesions contiguously near and around key cardiac structures. These procedures are complex and technically challenging and, even when performed by the most skilled physician, nearly half of patients undergo repeat procedures due to incomplete elimination of the arrhythmogenic pathways. This thesis aims to incorporate innovative design to improve catheter stability and maneuverability through the development of robotic platforms that enable precise placement of reproducibly durable ablation lesions. The first part of this thesis deals with the challenges to lesion delivery imposed by cardiorespiratory motion. One of the main determinants of the delivery of durable and transmural RF lesions is the ability to define and maintain a constant contact force between the catheter tip electrode and cardiac tissue, which is hampered by the presence of cardiorespiratory motion. To address this need, I developed and evaluated a novel catheter contact-force control device. The compact electromechanical add-on tool monitors catheter-tissue contact force in real-time and simultaneously adjusts the position of a force-sensing ablation catheter within a steerable sheath to compensate for the change in contact force. In a series of in vitro and in vivo experiments, the contact-force control device demonstrated an ability to: a) maintain an average force to within 1 gram of a set level; b) reduce contact-force variation to below 5 grams (2-8-fold improvement over manual catheter intervention); c) ensure the catheter tip never lost contact with the tissue and never approached dangerous force levels; and importantly, d) deliver reproducible RF ablation lesions regardless of cardiac tissue motion, which were of the same depth and volume as lesions delivered in the absence of tissue motion. In the second part of the thesis, I describe a novel steerable sheath and catheter robotic navigation system, which incorporates the catheter contact-force controller. The robotic platform enables precise and accurate manipulation of a remote conventional steerable sheath and permits catheter-tissue contact-force control. The robotic navigation system was evaluated in vitro using a phantom that combines stationary and moving targets within an in vitro model representing a beating heart. An electrophysiologist used the robotic system to remotely navigate the sheath and catheter tip to select targets and compared the accuracy of reaching these targets performing the same tasks manually. Robotic intervention resulted in significantly higher accuracy and significantly improved the contact-force profile between the catheter tip and moving tissue-mimicking material. Our studies demonstrate that using available contact-force information within a robotic system can ensure precise and accurate placement of reliably transmural RF ablation lesions. These robotic systems can be valuable tools used to optimize RF lesion delivery techniques and ultimately improve clinical outcomes for AF ablation therapy

    Eliminating the effects of motion during radiofrequency lesion delivery using a novel contact-force controller.

    Get PDF
    INTRODUCTION: Catheter-tissue contact force is a determinant of radiofrequency (RF) ablation lesion effectiveness. However, ablation on a beating heart is subject to force variability, making it difficult to optimally deliver consistently durable and transmural lesions. This work evaluates improvements in contact force stability and lesion reproducibility by using a catheter contact-force controller (CFC) during lesion delivery in vitro and in vivo. METHODS AND RESULTS: Using a sheath and force-sensing catheter, an experienced operator attempted to maintain a constant force of 20 g at targets within the atria and left ventricle of a pig manually and using the CFC; the average force and contact-force variation (CFV) achieved using each approach were compared. Ablation lesions (20 W, 30 seconds, 17 mL/min irrigation) were created in bovine tissue samples mounted on a platform programmed to reproduce clinically relevant motion. CFC-assisted lesions were delivered to stationary and moving tissue with forces of 5 to 35  g. Mimicking manual intervention, lesions were also delivered to moving tissue while the CFC was disabled. Resultant lesion volumes were compared using two-way analysis of variance. When using the CFC, the average force was within 1 g of the set level, with a CFV less than 5 g, during both in vitro and in vivo experiments. Reproducible and statistically identical (P = .82) lesion volumes proportional to the set force were achieved in both stationary and moving tissue when the CFC was used. CONCLUSIONS: CFC assistance maintains constant force in vivo and removes effect of motion on lesion volume during RF lesion delivery

    Computer-Assisted Electroanatomical Guidance for Cardiac Electrophysiology Procedures

    Get PDF
    Cardiac arrhythmias are serious life-threatening episodes affecting both the aging population and younger patients with pre-existing heart conditions. One of the most effective therapeutic procedures is the minimally-invasive catheter-driven endovascular electrophysiology study, whereby electrical potentials and activation patterns in the affected cardiac chambers are measured and subsequent ablation of arrhythmogenic tissue is performed. Despite emerging technologies such as electroanatomical mapping and remote intraoperative navigation systems for improved catheter manipulation and stability, successful ablation of arrhythmias is still highly-dependent on the operator’s skills and experience. This thesis proposes a framework towards standardisation in the electroanatomical mapping and ablation planning by merging knowledge transfer from previous cases and patient-specific data. In particular, contributions towards four different procedural aspects were made: optimal electroanatomical mapping, arrhythmia path computation, catheter tip stability analysis, and ablation simulation and optimisation. In order to improve the intraoperative electroanatomical map, anatomical areas of high mapping interest were proposed, as learned from previous electrophysiology studies. Subsequently, the arrhythmic wave propagation on the endocardial surface and potential ablation points were computed. The ablation planning is further enhanced, firstly by the analysis of the catheter tip stability and the probability of slippage at sparse locations on the endocardium and, secondly, by the simulation of the ablation result from the computation of convolutional matrices which model mathematically the ablation process. The methods proposed by this thesis were validated on data from patients with complex congenital heart disease, who present unusual cardiac anatomy and consequently atypical arrhythmias. The proposed methods also build a generic framework for computer guidance of electrophysiology, with results showing complementary information that can be easily integrated into the clinical workflow.Open Acces

    Design and Evaluation of a Catheter Contact-Force Controller for Cardiac Ablation Therapy.

    Get PDF
    GOAL: Maintaining a constant contact force (CF) of an ablation catheter during cardiac catheter ablation therapy is clinically challenging due to inherent myocardial motion, often resulting in poor ablation of arrhythmogenic substrates. To enable a prescribed contact force to be applied during ablation, a catheter contact force controller (CCFC) was developed. METHODS: The system includes a hand-held device attached to a commercial catheter and steerable sheath. A compact linear motor assembly attaches to an ablation catheter and autonomously controls its relative position within the shaft of the steerable sheath. A closed-loop control system is implemented within embedded electronics to enable real-time catheter-tissue contact force control. To evaluate the performance of the CCFC, a linear motion phantom was used to impose a series of physiological CF profiles; lesion CF was controlled at prescribed levels ranging from 15 to 40 g. RESULTS: For a prescribed CF of 25 g, the CCFC was able to regulate the CF with a root mean squared error of 3.7 ± 0.7 g. The ability of the CCFC to retract the catheter upon sudden changes in tissue motion, which may have caused tissue damage, was also demonstrated. Finally, the device was able to regulate the CF for a predetermined amount of time according to a force-time integral model. CONCLUSION: The developed CCFC is capable of regulating catheter-tissue CF in a laboratory setting that mimics clinical ablation therapy. SIGNIFICANCE: Catheter-tissue CF control promises to improve the precision and success of ablation lesion delivery

    Cardiac Arrhythmias

    Get PDF
    This book is useful for physicians taking care of patients with cardiac arrhythmias and includes six chapters written by experts in their field. Chapter 1 discusses basic mechanisms of cardiac arrhythmias. Chapter 2 discusses the chronobiological aspects of the impact of apnoic episodes on ventricular arrhythmias. Chapter 3 discusses navigation, detection, and tracking during cardiac ablation interventions. Chapter 4 discusses epidemiology and pathophysiology of ventricular arrhythmias in several noncardiac diseases, methods used to assess arrhythmia risk, and their association with long-term outcomes. Chapter 5 discusses the treatment of ventricular arrhythmias including indications for implantation of an AICD for primary and for secondary prevention in patients with and without congestive heart failure. Chapter 6 discusses surgical management of atrial fibrillation

    Simultaneous left atrium anatomy and scar segmentations via deep learning in multiview information with attention

    Get PDF
    Three-dimensional late gadolinium enhanced (LGE) cardiac MR (CMR) of left atrial scar in patients with atrial fibrillation (AF) has recently emerged as a promising technique to stratify patients, to guide ablation therapy and to predict treatment success. This requires a segmentation of the high intensity scar tissue and also a segmentation of the left atrium (LA) anatomy, the latter usually being derived from a separate bright-blood acquisition. Performing both segmentations automatically from a single 3D LGE CMR acquisition would eliminate the need for an additional acquisition and avoid subsequent registration issues. In this paper, we propose a joint segmentation method based on multiview two-task (MVTT) recursive attention model working directly on 3D LGE CMR images to segment the LA (and proximal pulmonary veins) and to delineate the scar on the same dataset. Using our MVTT recursive attention model, both the LA anatomy and scar can be segmented accurately (mean Dice score of 93% for the LA anatomy and 87% for the scar segmentations) and efficiently (0.27 s to simultaneously segment the LA anatomy and scars directly from the 3D LGE CMR dataset with 60–68 2D slices). Compared to conventional unsupervised learning and other state-of-the-art deep learning based methods, the proposed MVTT model achieved excellent results, leading to an automatic generation of a patient-specific anatomical model combined with scar segmentation for patients in AF

    A statistical method for retrospective cardiac and respiratory motion gating of interventional cardiac x-ray images

    Get PDF
    Purpose: Image-guided cardiac interventions involve the use of fluoroscopic images to guide the insertion and movement of interventional devices. Cardiorespiratory gating can be useful for 3D reconstruction from multiple x-ray views and for reducing misalignments between 3D anatomical models overlaid onto fluoroscopy. Methods: The authors propose a novel and potentially clinically useful retrospective cardiorespiratory gating technique. The principal component analysis (PCA) statistical method is used in combination with other image processing operations to make our proposed masked-PCA technique suitable for cardiorespiratory gating. Unlike many previously proposed techniques, our technique is robust to varying image-content, thus it does not require specific catheters or any other optically opaque structures to be visible. Therefore, it works without any knowledge of catheter geometry. The authors demonstrate the application of our technique for the purposes of retrospective cardiorespiratory gating of normal and very low dose x-ray fluoroscopy images. Results: For normal dose x-ray images, the algorithm was validated using 28 clinical electrophysiology x-ray fluoroscopy sequences (2168 frames), from patients who underwent radiofrequency ablation (RFA) procedures for the treatment of atrial fibrillation and cardiac resynchronization therapy procedures for heart failure. The authors established end-systole, end-expiration, and end-inspiration success rates of 97.0%, 97.9%, and 97.0%, respectively. For very low dose applications, the technique was tested on ten x-ray sequences from the RFA procedures with added noise at signal to noise ratio (SNR) values of √50, √10, √8, √6, √5, √2 and √1 to simulate the image quality of increasingly lower dose x-ray images. Even at the low SNR value of √2, representing a dose reduction of more than 25 times, gating success rates of 89.1%, 88.8%, and 86.8% were established. Conclusions: The proposed technique can therefore extract useful information from interventional x-ray images while minimizing exposure to ionizing radiation. © 2014 American Association of Physicists in Medicine