7,863 research outputs found

    A comparative study of electric power distribution systems for spacecraft

    Get PDF
    The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems

    Issues concerning centralized versus decentralized power deployment

    Get PDF
    The results of a study of proposed lunar base architectures to identify issues concerning centralized and decentralized power system deployment options are presented. The power system consists of the energy producing system (power plant), the power conditioning components used to convert the generated power into the form desired for transmission, the transmission lines that conduct this power from the power sources to the loads, and the primary power conditioning hardware located at the user end. Three power system architectures, centralized, hybrid, and decentralized, were evaluated during the course of this study. Candidate power sources were characterized with respect to mass and radiator area. Two electrical models were created for each architecture to identify the preferred method of power transmission, dc or ac. Each model allowed the transmission voltage level to be varied at assess the impact on power system mass. The ac power system models also permitted the transmission line configurations and placements to determine the best conductor construction and installation location. Key parameters used to evaluate each configuration were power source and power conditioning component efficiencies, masses, and radiator areas; transmission line masses and operating temperatures; and total system mass

    Suppression of common-mode voltage in a PWM rectifier/inverter system

    Get PDF
    This paper proposes a PWM rectifier/inverter system capable of suppressing not only supply harmonic currents but also electromagnetic interference (EMI). An active common-noise canceler (ACC) developed for this system is characterized by sophisticated connection of a common-mode transformer which can compensate for common-mode voltages produced by both PWM rectifier and inverter. As a result, the size of the common-mode transformer can be reduced to 1/3, compared with the previously proposed ACC. A prototype PWM rectifier/inverter system (2.2 kW) has been implemented and tested. Some experimental results show reduction characteristics of the supply harmonic current and EMI</p

    Safety issues in PV systems: design choices for a secure fault detection and for preventing fire risk

    Get PDF
    Photovoltaic systems have played a key role over the last decade in the evolution of the electricity sector. In terms of safety design, it's important to consider that a PV plant constitutes a special system of generation, where the Direct Current (DC) presence results in changes to the technical rules. Moreover, if certain electrical faults occur, the plant is a possible source of fire. Choices regarding the grounding of the generator and its protection devices are fundamental for a design that evaluates fire risk. The subject of the article is the analysis of the relation between electrical phenomena in PV systems and the fire risk related to ensuring appropriate fault detection by the electrical protection system. A description of a grid-connected PV system is followed firstly by a comparison of the design solutions provided by international Standards, and secondly by an analysis of electrical phenomena which may trigger a fire. A study of two existing PV systems, where electrical faults have resulted in fires, is then presented. The study highlights the importance of checking all possible failure modes in a PV system design phase, to assess fire risk in advance. Some guidelines for the mitigation of electrical faults that may result in a fire are finally provided

    Power processor for a 30cm ion thruster

    Get PDF
    A thermal vacuum power processor for the NASA Lewis 30cm Mercury Ion Engine was designed, fabricated and tested to determine compliance with electrical specifications. The power processor breadboard used the silicon controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to an ion engine. The power processor includes a digital interface unit to process all input commands and internal telemetry signals so that operation is compatible with a central computer system. The breadboard was tested in a thermal vacuum environment. Integration tests were performed with the ion engine and demonstrate operational compatibility and reliable operation without any component failures. Electromagnetic interference data were also recorded on the design to provide information on the interaction with total spacecraft

    Power balancing and dc fault ride through in DC grids with dc hubs and wind farms

    Get PDF
    Acknowledgment This project was funded by European Research Council under the Ideas program in FP7; grant no 259328, 2010.Peer reviewedPostprin

    Development of a micrometeoroid accelerator Final report

    Get PDF
    Design and performance of arc plasma micrometeoroid accelerator system

    Current-Source DC-DC Converter for Fiber-Optic Communication Systems

    Get PDF
    In this thesis, a proof of concept for a current-source DC-DC converter for powering sensors used in an underwater communications system is presented. The proposed converter steps down an input current of 0.9 A to 0.625 A, while maintaining an output voltage of 24 V and output power of 15 W. The complete steady-state analysis and design of the proposed converter in its single-stage form is also explained in detail. Performance evaluation of the proposed converter was carried out using LTspice. Results of the simulation demonstrate that the design was able to produce average output current of 0.639 A at maximum output power of 15.292 W while maintaining 24.39 V regulated output voltage. The overall efficiency of the converter was determined to be 88.73% and the output voltage ripple was calculated to be 0.4%, meeting the original specifications of the design

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Optimised design of isolated industrial power systems and system harmonics

    Get PDF
    This work has focused on understanding the nature and impact of non-linear loads on isolated industrial power systems. The work was carried out over a period of 8 years on various industrial power systems: off-shore oil and gas facilities including an FPSO, a wellhead platform, gas production platforms, a mineral processing plant and an LNG plant. The observations regarding non-linear loads and electrical engineering work carried out on these facilities were incorporated into the report.A significant literature describing non-linear loads and system harmonics on industrial power systems was collected and reviewed. The literature was classified into five categories: industrial plants and system harmonics, non-linear loads as the source of current harmonics, practical issues with system harmonics, harmonic mitigation strategies and harmonic measurements.Off-shore oil and gas production facilities consist of a small compact power system. The power system incorporates either its own power generation or is supplied via subsea cable from a remote node. Voltage selection analysis and voltage drop calculation using commercially available power system analysis software are appropriate tools to analyse these systems. Non-linear loads comprise DC rectifiers, variable speed drives, UPS systems and thyristor controlled process heaters. All nonlinear loads produce characteristic and non-characteristic harmonics, while thyristor controlled process heaters generate inter-harmonics. Due to remote location, harmonic survey is not a common design practice. Harmonic current measurements during factory acceptance tests do not provide reliable information for accurate power system analysis.A typical mineral processing plant, located in a remote area includes its own power station. The power generation capacity of those systems is an order of magnitude higher than the power generation of a typical off-shore production facility. Those systems comprise large non-linear loads generating current and voltage interharmonics. Harmonic measurements and harmonic survey will provide a full picture of system harmonics on mineral processing plants which is the only practical way to determine system harmonics. Harmonic measurements on gearless mill drive at the factory are not possible as the GMD is assembled for the first time on site.LNG plants comprise large non-linear loads driving gas compressor, however those loads produce integer harmonics. Design by analysis process is an alternative to the current design process based on load lists. Harmonic measurements and harmonic survey provide a reliable method for determining power system harmonics in an industrial power system
    • …
    corecore