148 research outputs found

    On the Application of Mechanical Vibration in Robotics-Assisted Soft Tissue Intervention

    Get PDF
    Mechanical vibration as a way of transmitting energy has been an interesting subject to study. While cyclic oscillation is usually associated with fatigue effect, and hence a detrimental factor in failure of structures and machineries, by controlled transmission of vibration, energy can be transferred from the source to the target. In this thesis, the application of such mechanical vibration in a few surgical procedures is demonstrated. Three challenges associated with lung cancer diagnosis and treatment are chosen for this purpose, namely, Motion Compensation, tumor targeting in lung Needle Insertion and Soft Tissue Dissection: A robotic solution is proposed for compensating for the undesirable oscillatory motion of soft tissue (caused by heart beat and respiration) during needle insertion in the lung. An impedance control strategy based on a mechanical vibratory system is implemented to minimize the tissue deformation during needle insertion. A prototype was built to evaluate the proposed approach using: 1) two Mitsubishi PA10-7C robots, one for manipulating the macro part and the other for mimicking the tissue motion, 2) one motorized linear stage to handle the micro part, and 3) a Phantom Omni haptic device for remote manipulation. Experimental results are given to demonstrate the performance of the motion compensation system. A vibration-assisted needle insertion technique has been proposed in order to reduce needle–tissue friction. The LuGre friction model is employed as a basis for the study and the model is extended and analyzed to include the impact of high-frequency vibration on translational friction. Experiments are conducted to evaluate the role of insertion speed as well as vibration frequency on frictional effects. In the experiments conducted, an 18 GA brachytherapy needle was vibrated and inserted into an ex-vivo soft tissue sample using a pair of amplified piezoelectric actuators. Analysis demonstrates that the translational friction can be reduced by introducing a vibratory low-amplitude motion onto a regular insertion profile, which is usually performed at a constant rate. A robotics-assisted articulating ultrasonic surgical scalpel for minimally invasive soft tissue cutting and coagulation is designed and developed. For this purpose, the optimal design of a Langevin transducer with stepped horn profile is presented for internal-body applications. The modeling, optimization and design of the ultrasonic scalpel are performed through equivalent circuit theory and verified by finite element analysis. Moreover, a novel surgical wrist, compatible with the da Vinci® surgical system, with decoupled two degrees-of-freedom (DOFs) is developed that eliminates the strain of pulling cables and electrical wires. The developed instrument is then driven using the dVRK (da Vinci® research kit) and the Classic da Vinci® surgical system

    Prevalence of haptic feedback in robot-mediated surgery : a systematic review of literature

    Get PDF
    © 2017 Springer-Verlag. This is a post-peer-review, pre-copyedit version of an article published in Journal of Robotic Surgery. The final authenticated version is available online at: https://doi.org/10.1007/s11701-017-0763-4With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.Peer reviewe

    Comparative Review of Endoscopic Devices Articulations Technologies Developed for Minimally Invasive Medical Procedures

    Get PDF
    This study introduces a comparative performance analysis of the technological solutions that have been used to build distal active articulations for minimally invasive medical procedures. The aim is to provide a practical and concise database and classification tool for anyone that wants to learn more about the technologies involved in minimally invasive medical devices, or for any designer interested in further improving these devices. A review of the different articulations developed in this field is therefore performed and organized by both actuation technology and structural architecture. Details are presented concerning the mechanical structures as well as the actuation and the mechanical transmission technologies available. The solutions are evaluated keeping as a reference some chosen required performances and characteristics for minimally invasive surgical procedures. Finally, a quantified comparison chart of these devices is given regarding selected criteria of interest for minimally invasive surgical application

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    Flexible robotic device for spinal surgery

    No full text
    Surgical robots have proliferated in recent years, with well-established benefits including: reduced patient trauma, shortened hospitalisation, and improved diagnostic accuracy and therapeutic outcome. Despite these benefits, many challenges in their development remain, including improved instrument control and ergonomics caused by rigid instrumentation and its associated fulcrum effect. Consequently, it is still extremely challenging to utilise such devices in cases that involve complex anatomical pathways such as the spinal column. The focus of this thesis is the development of a flexible robotic surgical cutting device capable of manoeuvring around the spinal column. The target application of the flexible surgical tool is the removal of cancerous tumours surrounding the spinal column, which cannot be excised completely using the straight surgical tools in use today; anterior and posterior sections of the spine must be accessible for complete tissue removal. A parallel robot platform with six degrees of freedom (6 DoFs) has been designed and fabricated to direct a flexible cutting tool to produce the necessary range of movements to reach anterior and posterior sections of the spinal column. A flexible water jet cutting system and a flexible mechanical drill, which may be assembled interchangeably with the flexible probe, have been developed and successfully tested experimentally. A model predicting the depth of cut by the water jet was developed and experimentally validated. A flexion probe that is able to guide the surgical cutting device around the spinal column has been fabricated and tested with human lumber model. Modelling and simulations show the capacity for the flexible surgical system to enable entering the posterior side of the human lumber model and bend around the vertebral body to reach the anterior side of the spinal column. A computer simulation with a full Graphical User Interface (GUI) was created and used to validate the system of inverse kinematic equations for the robot platform. The constraint controller and the inverse kinematics relations are both incorporated into the overall positional control structure of the robot, and have successfully established a haptic feedback controller for the 6 DoFs surgical probe, and effectively tested in vitro on spinal mock surgery. The flexible surgical system approached the surgery from the posterior side of the human lumber model and bend around the vertebral body to reach the anterior side of the spinal column. The flexible surgical robot removed 82% of mock cancerous tissue compared to 16% of tissue removed by the rigid tool.Open Acces

    A cumulative index to the 1977 issues of a continuing bibliography on aerospace medicine and biology

    Get PDF
    This publication is a cumulative index to the abstracts contained in the Supplements 164 through 175 of Aerospace Medicine and Biology: A Continuing Bibliography. It includes three indexes-- subject, personal author, and corporate source

    Mechanical Manipulation and Characterization of Biological Cells

    Get PDF
    Mechanical manipulation and characterization of an individual biological cell is currently one of the most exciting research areas in the field of medical robotics. Single cell manipulation is an important process in intracytoplasmic sperm injection (ICSI), pro-nuclei DNA injection, gene therapy, and other biomedical areas. However, conventional cell manipulation requires long training and the success rate depends on the experience of the operator. The goal of this research is to address the drawbacks of conventional cell manipulation by using force and vision feedback for cell manipulation tasks. We hypothesize that force feedback plays an important role in cell manipulation and possibly helps in cell characterization. This dissertation will summarize our research on: 1) the development of force and vision feedback interface for cell manipulation, 2) human subject studies to evaluate the addition of force feedback for cell injection tasks, 3) the development of haptics-enabled atomic force microscope system for cell indentation tasks, 4) appropriate analytical model for characterizing the mechanical property of mouse embryonic stem cells (mESC) and 5) several indentation studies on mESC to determine the mechanical property of undifferentiated and early differentiating (6 days under differentiation conditions) mESC. Our experimental results on zebrafish egg cells show that a system with force feedback capability when combined with vision feedback can lead to potentially higher success rates in cell injection tasks. Using this information, we performed experiments on mESC using the AFM to understand their characteristics in the undifferentiated pluripotent state as well as early differentiating state. These experiments were done on both live as well as fixed cells to understand the correlation between the two during cell indentation studies. Our results show that the mechanical property of undifferentiated mESC differs from early differentiating (6th day) mESC in both live and fixed cells. Thus, we hypothesize that mechanical characterization studies will potentially pave the way for developing a high throughput system with force feedback capability, to understand and predict the differentiation path a particular pluripotent cell will follow. This finding could also be used to develop improved methods of targeted cellular differentiation of stem cells for therapeutic and regenerative medicine

    Technology 2001: The Second National Technology Transfer Conference and Exposition, volume 2

    Get PDF
    Proceedings of the workshop are presented. The mission of the conference was to transfer advanced technologies developed by the Federal government, its contractors, and other high-tech organizations to U.S. industries for their use in developing new or improved products and processes. Volume two presents papers on the following topics: materials science, robotics, test and measurement, advanced manufacturing, artificial intelligence, biotechnology, electronics, and software engineering

    Controlled surface manipulation at the nanometer scale based on the atomic force microscope

    Get PDF
    The object of this thesis is the development of theoretical and experimental methods for the controlled manipulation of surfaces at the nanometer scale, including the design, construction and experimental demonstration of an atomic force microscope (AFM) based manipulator. The transfer function description of an AFM system not only offers a theoretical dynamic characterization but, additionally, it is appropriate for the analysis of stability and controllability of different system configurations, i.e. different inputs and outputs. In this thesis, transfer functions are derived that correspond to a realistic model of the AFM sensor, including all its resonance modes and the tip-sample interaction. This theoretical description is then validated using the frequency response along an AFM cantilever. Different experimental and control techniques have been combined in the NanoManipulator system to optimize AFM lithography. Optical video microscopy allows a fast recognition of the sample and exact positioning of the AFM tip in the particular region of interest, while UV-laser ablation offers the possibility of noncontact manipulation of a wide range of materials, including biological specimens. Two different control approaches have been implemented in the NanoManipulator system: (i) automated control using a vector-scan module, and (ii) interactive control based on the use of a haptic interface. Using the NanoManipulator, the two different standard AFM lithography techniques based on dynamic methods (namely dynamic and modulated plowing) are compared by performing nanopatterning on thin resist films. The results reflect that modulated plowing, where the AFM tip is in permanent contact with the resist surface while the force is being modulated, offers the highest reliability, minimizing undesired side effects. The isolation and extraction of localized regions of human metaphase chromosomes represents a promising alternative to standard methods for the analysis of genetic material. The NanoManipulator is an excellent tool for such application, as it is here illustrated by comparing AFM based mechanical dissection and noncontact ablation on side by side chromosomes. The results are analyzed in situ using AFM imaging, revealing the high precision of mechanical dissection. Acoustical force nanolithography is a novel method for AFM based lithography where the cantilever is actuated using an acoustic wave coupled through the sample surface. The influence of acoustic wave frequency and magnitude, along with the preloading force of the cantilever are studied in detail. Acoustical force nanolithography can be used as a stand alone method or as a complement for the fine adjustment of manipulation forces
    corecore