397 research outputs found

    A reconfigurable medically cohesive biomedical front-end with ΣΔ ADC in 0.18µm CMOS

    Get PDF
    This paper presents a generic programmable analog front-end (AFE) for acquisition and digitization of various biopotential signals. This includes a lead-off detection circuit, an ultra-low current capacitively coupled signal conditioning stage with programmable gain and bandwidth, a new mixed signal automatic gain control (AGC) mechanism and a medically cohesive reconfigurable ΣΔ ADC. The full system is designed in UMC 0.18μm CMOS. The AFE achieves an overall linearity of more 10 bits with 0.47μW power consumption. The ADC provides 2nd order noise-shaping while using single integrator and an ENOB of ~11 bits with 5μW power consumption. The system was successfully verified for various ECG signals from PTB database. This system is intended for portable batteryless u-Healthcare devices

    Strategies towards high performance (high-resolution/linearity) time-to-digital converters on field-programmable gate arrays

    Get PDF
    Time-correlated single-photon counting (TCSPC) technology has become popular in scientific research and industrial applications, such as high-energy physics, bio-sensing, non-invasion health monitoring, and 3D imaging. Because of the increasing demand for high-precision time measurements, time-to-digital converters (TDCs) have attracted attention since the 1970s. As a fully digital solution, TDCs are portable and have great potential for multichannel applications compared to bulky and expensive time-to-amplitude converters (TACs). A TDC can be implemented in ASIC and FPGA devices. Due to the low cost, flexibility, and short development cycle, FPGA-TDCs have become promising. Starting with a literature review, three original FPGA-TDCs with outstanding performance are introduced. The first design is the first efficient wave union (WU) based TDC implemented in Xilinx UltraScale (20 nm) FPGAs with a bubble-free sub-TDL structure. Combining with other existing methods, the resolution is further enhanced to 1.23 ps. The second TDC has been designed for LiDAR applications, especially in driver-less vehicles. Using the proposed new calibration method, the resolution is adjustable (50, 80, and 100 ps), and the linearity is exceptionally high (INL pk-pk and INL pk-pk are lower than 0.05 LSB). Meanwhile, a software tool has been open-sourced with a graphic user interface (GUI) to predict TDCs’ performance. In the third TDC, an onboard automatic calibration (AC) function has been realized by exploiting Xilinx ZYNQ SoC architectures. The test results show the robustness of the proposed method. Without the manual calibration, the AC function enables FPGA-TDCs to be applied in commercial products where mass production is required.Time-correlated single-photon counting (TCSPC) technology has become popular in scientific research and industrial applications, such as high-energy physics, bio-sensing, non-invasion health monitoring, and 3D imaging. Because of the increasing demand for high-precision time measurements, time-to-digital converters (TDCs) have attracted attention since the 1970s. As a fully digital solution, TDCs are portable and have great potential for multichannel applications compared to bulky and expensive time-to-amplitude converters (TACs). A TDC can be implemented in ASIC and FPGA devices. Due to the low cost, flexibility, and short development cycle, FPGA-TDCs have become promising. Starting with a literature review, three original FPGA-TDCs with outstanding performance are introduced. The first design is the first efficient wave union (WU) based TDC implemented in Xilinx UltraScale (20 nm) FPGAs with a bubble-free sub-TDL structure. Combining with other existing methods, the resolution is further enhanced to 1.23 ps. The second TDC has been designed for LiDAR applications, especially in driver-less vehicles. Using the proposed new calibration method, the resolution is adjustable (50, 80, and 100 ps), and the linearity is exceptionally high (INL pk-pk and INL pk-pk are lower than 0.05 LSB). Meanwhile, a software tool has been open-sourced with a graphic user interface (GUI) to predict TDCs’ performance. In the third TDC, an onboard automatic calibration (AC) function has been realized by exploiting Xilinx ZYNQ SoC architectures. The test results show the robustness of the proposed method. Without the manual calibration, the AC function enables FPGA-TDCs to be applied in commercial products where mass production is required

    Ultra low power wearable sleep diagnostic systems

    Get PDF
    Sleep disorders are studied using sleep study systems called Polysomnography that records several biophysical parameters during sleep. However, these are bulky and are typically located in a medical facility where patient monitoring is costly and quite inefficient. Home-based portable systems solve these problems to an extent but they record only a minimal number of channels due to limited battery life. To surmount this, wearable sleep system are desired which need to be unobtrusive and have long battery life. In this thesis, a novel sleep system architecture is presented that enables the design of an ultra low power sleep diagnostic system. This architecture is capable of extending the recording time to 120 hours in a wearable system which is an order of magnitude improvement over commercial wearable systems that record for about 12 hours. This architecture has in effect reduced the average power consumption of 5-6 mW per channel to less than 500 uW per channel. This has been achieved by eliminating sampled data architecture, reducing the wireless transmission rate and by moving the sleep scoring to the sensors. Further, ultra low power instrumentation amplifiers have been designed to operate in weak inversion region to support this architecture. A 40 dB chopper-stabilised low power instrumentation amplifiers to process EEG were designed and tested to operate from 1.0 V consuming just 3.1 uW for peak mode operation with DC servo loop. A 50 dB non-EEG amplifier continuous-time bandpass amplifier with a consumption of 400 nW was also fabricated and tested. Both the amplifiers achieved a high CMRR and impedance that are critical for wearable systems. Combining these amplifiers with the novel architecture enables the design of an ultra low power sleep recording system. This reduces the size of the battery required and hence enables a truly wearable system.Open Acces

    Development and Experimental Analysis of Wireless High Accuracy Ultra-Wideband Localization Systems for Indoor Medical Applications

    Get PDF
    This dissertation addresses several interesting and relevant problems in the field of wireless technologies applied to medical applications and specifically problems related to ultra-wideband high accuracy localization for use in the operating room. This research is cross disciplinary in nature and fundamentally builds upon microwave engineering, software engineering, systems engineering, and biomedical engineering. A good portion of this work has been published in peer reviewed microwave engineering and biomedical engineering conferences and journals. Wireless technologies in medicine are discussed with focus on ultra-wideband positioning in orthopedic surgical navigation. Characterization of the operating room as a medium for ultra-wideband signal transmission helps define system design requirements. A discussion of the first generation positioning system provides a context for understanding the overall system architecture of the second generation ultra-wideband positioning system outlined in this dissertation. A system-level simulation framework provides a method for rapid prototyping of ultra-wideband positioning systems which takes into account all facets of the system (analog, digital, channel, experimental setup). This provides a robust framework for optimizing overall system design in realistic propagation environments. A practical approach is taken to outline the development of the second generation ultra-wideband positioning system which includes an integrated tag design and real-time dynamic tracking of multiple tags. The tag and receiver designs are outlined as well as receiver-side digital signal processing, system-level design support for multi-tag tracking, and potential error sources observed in dynamic experiments including phase center error, clock jitter and drift, and geometric position dilution of precision. An experimental analysis of the multi-tag positioning system provides insight into overall system performance including the main sources of error. A five base station experiment shows the potential of redundant base stations in improving overall dynamic accuracy. Finally, the system performance in low signal-to-noise ratio and non-line-of-sight environments is analyzed by focusing on receiver-side digitally-implemented ranging algorithms including leading-edge detection and peak detection. These technologies are aimed at use in next-generation medical systems with many applications including surgical navigation, wireless telemetry, medical asset tracking, and in vivo wireless sensors
    corecore