19,754 research outputs found

    Application of distributed optical fiber sensors for the health monitoring of two real structures in Barcelona

    Get PDF
    This is an Accepted Manuscript of an article published by Taylor & Francis Group in Structure and Infrastructure Engineering on 2018, available online at: http://www.tandfonline.com/10.1080/15732479.2018.1438479The versatility and ease of installation of Distributed Optical Fibre Sensors (DOFS) compared with traditional monitoring systems are important characteristics to consider when facing the Structural Health Monitoring (SHM) of real world structures. The DOFS used in this study provide continuous (in space) strain data along the optical fibre with high spatial resolution. The main issues and results of two different existing structures monitored with DOFS, are described in this paper. The main SHM results of the rehabilitation of an historical building used as hospital and the enlargement of a pre-stressed concrete bridge are presented. The results are obtained using a novel DOFS based on an Optical Backscattered Reflectometry (OBR) technique. The application of the optical fibre monitoring system to two different materials (masonry and concrete) provides also important insights on the great possibilities of this technique when monitoring existing structures. In fact, the influence of strain transfer between the DOFS and the bonding surface is one of the principal effects that should be considered in the application of the OBR technique to real structures. Moreover, and because structural surfaces generally present considerable roughness, the procedure to attach the optical fibre to the two monitored structures is described.Peer ReviewedPostprint (author's final draft

    Comparison of theoretical heat transfer model with results from experimental monitoring installed in a refurbishment with ventilated facade

    Get PDF
    One of the main points to consider when a building is renovated is the improvement of its energy efficiency, minimizing the heat loss through the enclosures and its heating consumption. Under this scope idea a ventilated facade was designed and incorporated in an educational building located in the city of Burgos (Spain). The main objective of this document is a comparison between the theoretical model of heat transfer across the building envelope separating the environment and the interior space, and the heat intake through a linear regression model with installed experimental monitoring. For this it has been necessary to carry out an exhaustive study of the thermal transmission of each one of the materials that make up the thermal envelope of the building, as well as the linear thermal bridges that can be produced before and after the renovation. In addition, thanks to the monitoring installed in the demonstrator building, the interior and exterior temperatures and the heat consumption of each of the radiators is known. In this way expected and real energy savings have been compared

    Combining ground penetrating radar and seismic surveys in the assessment of cultural heritage buildings: The study of roofs, columns, and ground of the gothic church Santa Maria del Mar, in Barcelona (Spain)

    Get PDF
    Combined non-destructive techniques are applied in the study of a historical building in Barcelona. Santa Maria del Mar is a magnificent Mediterranean gothic church built between 1329 and 1383. Two of the most important characteristics of this building are the slender columns and the almost flat rooftop. This structure, used to create a visual impression of a unique space, transmits high loads to the tall columns. Previous to restoration, vaults, roofs, and columns were extensively assessed with non-destructive tests, in order to improve the knowledge of those structures. This information will be used in further simulations to analyse load distributions at each part of the structure. Ground and floor were also studied. The analysis of the columns was based on ground- penetrating radar (GPR) surveys and on seismic tomography. Finally, the dynamic behaviour of the structure was determined by seismic monitoring of the main nave and the bell tower. Results obtained at the radar survey highlight the existence of unexpected anomalies in homogeneous materials, supporting the hypothesis of an inner structure between arches and roof composed by hollow elements. Seismic tomography defined the inner geometry of the columns and detected some damage or lower quality stone in various zones. Seismic monitoring established the perfect junction between the bell tower and the main nave. GPR survey on the floor allowed detecting a large number of graves, and some images suggest the existence of large underground walls and some of the foundations of the main façade.Peer ReviewedPostprint (published version

    Evaluating the impact of an enhanced energy performance standard on load-bearing masonry domestic construction: Understanding the gap between designed and real performance: lessons from Stamford Brook.

    Get PDF
    This report is aimed at those with interests in the procurement, design and construction of new dwellings both now and in the coming years as the Government’s increasingly stringent targets for low and zero carbon housing approach. It conveys the results of a research project, carried out between 2001 and 2008, that was designed to evaluate the extent to which low carbon housing standards can be achieved in the context of a large commercial housing development. The research was led by Leeds Metropolitan University in collaboration with University College London and was based on the Stamford Brook development in Altrincham, Cheshire. The project partners were the National Trust, Redrow and Taylor Wimpey and some 60 percent of the planned 700 dwelling development has been completed up to June 2008. As the UK house building industry and its suppliers grapple with the challenges of achieving zero carbon housing by 2016, the lessons arising from this project are timely and of considerable value. Stamford Brook has demonstrated that designing masonry dwellings to achieve an enhanced energy standard is feasible and that a number of innovative approaches, particularly in the area of airtightness, can be successful. The dwellings, as built, exceed the Building Regulations requirements in force at the time but tests on the completed dwellings and longer term monitoring of performance has shown that, overall, energy consumption and carbon emissions, under standard occupancy, are around 20 to 25 percent higher than design predictions. In the case of heat loss, the discrepancy can be much higher. The report contains much evidence of considerable potential but points out that realising the design potential requires a fundamental reappraisal of processes within the industry from design and construction to the relationship with its supply chain and the development of the workforce. The researchers conclude that, even when builders try hard, current mainstream technical and organisational practices together with industry cultures present barriers to consistent delivery of low and zero carbon performance. They suggest that the underlying reasons for this are deeply embedded at all levels of the house building industry. They point out also that without fundamental change in processes and cultures, technological innovations, whether they be based on traditional construction or modern methods are unlikely to reach their full potential. The report sets out a series of wide ranging implications for new housing in the UK, which are given in Chapter 14 and concludes by firmly declaring that cooperation between government, developers, supply chains, educators and researchers will be crucial to improvement. The recommendations in this report are already being put into practice by the researchers at Leeds Metropolitan University and University College London in their teaching and in further research projects. The implications of the work have been discussed across the industry at a series of workshops undertaken in 2008 as part of the LowCarb4Real project (see http://www.leedsmet.ac.uk/as/cebe/projects/lowcarb4real/index.htm). In addition, the learning is having an impact on the work of the developers (Redrow and Taylor Wimpey) who, with remarkable foresight and enthusiasm, hosted the project. This report seeks to make the findings more widely available and is offered for consideration by everyone who has a part to play in making low and zero carbon housing a reality

    Dynamic investigation on the Mirandola bell tower in post-earthquake scenarios

    Get PDF
    After the seismic events of the 20th and 29th of May 2012 in Emilia (Italy), most of the monumental and historic buildings of the area were severely damaged. In a few structures, partial collapse mechanisms were observed (e.g. façade tilting, out-of-plane overturning of panels
). This paper presents the case-study of the bell tower of the Santa Maria Maggiore cathedral, located in Mirandola (Italy). The dynamic response of the structure was evaluated through operational modal analysis using ambient vibrations, a consolidated non-destructive procedure that estimates the dynamic parameters of the bell-tower. The dynamic tests were carried out in pre-intervention and post-intervention conditions in order to understand the sensitivity of dynamic measurements to safety interventions. Furthermore, a comparative study is made with similar cases of undamaged masonry towers up to the 6th mode. Finally, an investigation on the state of connections and of the building itself is carried out via FE model updating

    Integrated dynamic and thermography investigation of Mallorca cathedral

    Get PDF
    An integrated investigation of engineering archaeometry was carried out using dynamic identification, dynamic monitoring and Infra-Red (IR) thermography for the study of the dynamic behavior of Mallorca cathedral in Spain. The cathedral is a large historical masonry structure built during 14-16th c. Dynamic identification and monitoring allowed the capturing of eight natural frequencies of the cathedral. IR thermography was used as a complementary inspection technique in the context of a continuous monitoring. Usually, IR thermography is used punctually for the inspection of a part of an inspected structure. Here an alternative was tried as the IR camera was installed for two two-weeks periods in the winter and in the summer of 2011 to monitor the stone surface temperature of a large portion of the cathedral. The correlation between the cathedral natural frequencies and the stone surface temperature of some selected structural elements was investigated and compared with the correlation with the external and the internal temperatures. It was found that the correlation with stone surface temperature was lower than that with external temperature. The study allowed a better understanding of the influence of temperature changes on the structure’s dynamic behavior.Peer ReviewedPostprint (published version

    Understanding and controlling the ingress of driven rain through exposed, solid wall masonry structures

    Get PDF
    Long term performance of historic buildings can be affected by many environmental factors, some of which become more apparent as the competence of the fabric deteriorates. Many tall historic buildings suffer from water ingress when exposed to driving rain conditions, particularly church towers in the south west of England. It is important to recognise that leakage can occur not only through flaws in the roof of a building but also through significant thicknesses of solid masonry. Identification of the most appropriate intervention requires an understanding of the way in which water might enter the structure and the assessment of potential repair options. While the full work schedule used an integrated assessment involving laboratory, field and archival work to assess the repairs which might be undertaken on these solid wall structures, this paper focuses on the laboratory work done to inform the writing of a Technical Advice Note on the effects of wind driven rain and moisture movement in historic structures (English Heritage, 2012). The laboratory work showed that grouting and rendering was effective at reducing water penetration without retarding drying rates, but that use of internal plastering also had a very beneficial effect

    A Hygrothermal Monitoring and Modelling of a Historic Roof

    Get PDF

    Calibration of the dynamic behaviour of incomplete structures in archeological sites: The case of Villa Diomede portico in Pompeii

    Get PDF
    This paper reports the research activities carried out on Villa Diomede in Pompeii, built during the "Pre-Roman period" (i.e. the 3rd century BC) and discovered between 1771 and 1774 during the archaeological excavations. It is one of the greatest private buildings of Pompeii and it is located on the western corner of the modern archeological site. Three levels compose the building: the ground floor, the lower quadriportico with a square plan and a series of colonnades on the four sides around the inner garden and the cryptoportico. Villa Diomede was damaged by the strong earthquake occurred in AD 63 that caused the collapse of the western pillars of the quadriportico and later damaged after the big eruption of Vesuvius in AD 79. In June 2015 a series of nondestructive tests (NDT) were carried out by the authors in order to obtain information on the state of conservation of the building and to assess its structural behavior. Direct and tomographic sonic pulse velocity tests, ground penetrating radar, endoscopies and operational modal analysis were performed on the remaining structural elements on the two levels of the Villa. The present paper reports the main outcomes and findings of ambient vibration tests implemented to extract the modal parameters in terms of eigenfrequencies, mode shapes and damping ratios. Operational modal analysis and output-only identification techniques were applied to single stone pillars of the quadriportico structure and then to the entire square colonnade of Villa Diomede. Results are then used to study the soil-structure interaction at a local level and extend the gained information for the numerical calibration of the whole structure. Thanks to this methodology a detailed model updating procedure of the quadriportico was performed to develop reliable numerical models for the implementation of advance structural and seismic analysis of this "incomplete" archaeological structure

    Open-source digital technologies for low-cost monitoring of historical constructions

    Get PDF
    This paper shows new possibilities of using novel, open-source, low-cost platforms for the structural health monitoring of heritage structures. The objective of the study is to present an assessment of increasingly available open-source digital modeling and fabrication technologies in order to identify the suitable counterparts of the typical components of a continuous static monitoring system for a historical construction. The results of the research include a simple case-study, which is presented with low-cost, open-source, calibrated components, as well as an assessment of different alternatives for deploying basic structural health monitoring arrangements. The results of the research show the great potential of these existing technologies that may help to promote a widespread and cost-efficient monitoring of the built cultural heritage. Such scenario may contribute to the onset of commonplace digital records of historical constructions in an open-source, versatile and reliable fashion.Peer ReviewedPostprint (author's final draft
    • 

    corecore