36 research outputs found

    Diamond MEMS Biosensors: Development and applications

    Get PDF
    This research focuses on the development a dielectrophoresis-enhanced microfluidic impedance biosensor (DEP-e-MIB) to enable fast response, real-time, label-free, and highly sensitive sensor for bacterial detection in clinical sample. The proposed design consists of application of dielectrophoresis (DEP) across a microfluidic channel to one of the impedance spectroscopy electrodes in order to improve the existent bacterial detection limits with impedance spectroscopy. In order to realize such a design, choice of electrode material with a wide electrochemical potential window for water is very important. Conventional electrode material, such as gold, are typically insulated for the application of DEP, and they fail when used open because the DEP voltages avoiding electrolysis do not provide enough force to move the bacteria. First, the use of nanodiamonds (ND) seeding gold surface to widen the electrochemical potential window is examined, since diamond has a wider potential window. ND seed coverage is a function of sonication time, ND concentration, and solvent of ND dispersion. Examining these parameters allowed us to increase the ND surface coverage to ~35%. With the highest ND coverage achievable, such electrodes are still susceptible to damage from electrolysis, however yield a unique leverage for impedance biosensing. When NDs is seeded at a 3x3 interdigitated electrode array, which act as electrically conductive islands between the electrodes and reduce the effective gap between the electrodes, thus allowing to perform impedance spectroscopy in solutions with low electrical conductivity such as ITS. The changes obtained in resistance to charge transfer with bacterial capture is nearly twice than that obtained with plain electrodes. Secondly, the feasibility of using boron-doped ultra nanocrystalline diamond (BD-UNCD) to apply DEP is tested without constructing a 3x3 IDE array. BD-UNCD electrodes can be used for DEP through tagging of the bacteria with immunolatex beads. This allows applying a larger DEP force on the bacteria. Since historically bead based assays are plagued with problems with non-specific binding, the role of different parameters including bead bioconjugation chemistry, bead PEGylation, BD-UNCD surface PEGylation, and DEP on specific and non-specific binding are tested. Most importantly DEP increases the specific binding and PEGylation of beads decreases the specific binding. Finally, a 3x3 IDE array with BD-UNCD was fabricated, and used impedance spectroscopy to test the suitability of BD-UNCD IDEs for impedance biosensing. The huge electrode resistance and the charge transfer resistance at BD-UNCD IDEs poses a problem for impedance biosensing as it will lead to lower sensitivity. BD-UNCD is the material of choice for applying DEP at open electrodes however gold is the choice of material for designing the chip interconnects. So the BD-UNCD layer should be as thin as possible and the interface between gold IDEs and the solution phase during DEP. The findings in this dissertation put us closer to realizing a DEP-eMIB

    Cellulose-Based Biosensing Platforms

    Get PDF
    Cellulose empowers measurement science and technology with a simple, low-cost, and highly transformative analytical platform. This book helps the reader to understand and build an overview of the state of the art in cellulose-based (bio)sensing, particularly in terms of the design, fabrication, and advantageous analytical performance. In addition, wearable, clinical, and environmental applications of cellulose-based (bio)sensors are reported, where novel (nano)materials, architectures, signal enhancement strategies, as well as real-time connectivity and portability play a critical role

    Application of microfluidics in biosensors

    Get PDF
    This chapter reviews the up-to-date researches in the field of biosensors integrated with microfluidic techniques, most of which are research works published within the last five years. The trend of integrating microfluidics into biosensing technologies is analyzed, as the features of microfluidics fulfills the technical requirements recently raised in the field of healthcare. The current research works are discussed in details based on the biological recognition events and the transduction mechanism. Their pros and cons are discussed. The potential of microfluidics-integrated biosensors are prospective and their future applications in the field of healthcare is revolutionary, for example in the field of portable and wearable biosensor, which can be fabricated at extremely low cost ad require no professional operation, and this can widen the application of biosensor especially for remote districts and extreme poverty populations. The possible future research interests in this field are proposed in this chapter

    BioMEMS

    Get PDF
    As technological advancements widen the scope of applications for biomicroelectromechanical systems (BioMEMS or biomicrosystems), the field continues to have an impact on many aspects of life science operations and functionalities. Because BioMEMS research and development require the input of experts who use different technical languages and come from varying disciplines and backgrounds, scientists and students can avoid potential difficulties in communication and understanding only if they possess a skill set and understanding that enables them to work at the interface of engineering and biosciences. Keeping this duality in mind throughout, BioMEMS: Science and Engineering Perspectives supports and expedites the multidisciplinary learning involved in the development of biomicrosystems. Divided into nine chapters, it starts with a balanced introduction of biological, engineering, application, and commercialization aspects of the field. With a focus on molecules of biological interest, the book explores the building blocks of cells and viruses, as well as molecules that form the self-assembled monolayers (SAMs), linkers, and hydrogels used for making different surfaces biocompatible through functionalization. The book also discusses: Different materials and platforms used to develop biomicrosystems Various biological entities and pathogens (in ascending order of complexity) The multidisciplinary aspects of engineering bioactive surfaces Engineering perspectives, including methods of manufacturing bioactive surfaces and devices Microfluidics modeling and experimentation Device level implementation of BioMEMS concepts for different applications. Because BioMEMS is an application-driven field, the book also highlights the concepts of lab-on-a-chip (LOC) and micro total analysis system (μTAS), along with their pertinence to the emerging point-of-care (POC) and point-of-need (PON) applications

    BioMEMS

    Get PDF
    As technological advancements widen the scope of applications for biomicroelectromechanical systems (BioMEMS or biomicrosystems), the field continues to have an impact on many aspects of life science operations and functionalities. Because BioMEMS research and development require the input of experts who use different technical languages and come from varying disciplines and backgrounds, scientists and students can avoid potential difficulties in communication and understanding only if they possess a skill set and understanding that enables them to work at the interface of engineering and biosciences. Keeping this duality in mind throughout, BioMEMS: Science and Engineering Perspectives supports and expedites the multidisciplinary learning involved in the development of biomicrosystems. Divided into nine chapters, it starts with a balanced introduction of biological, engineering, application, and commercialization aspects of the field. With a focus on molecules of biological interest, the book explores the building blocks of cells and viruses, as well as molecules that form the self-assembled monolayers (SAMs), linkers, and hydrogels used for making different surfaces biocompatible through functionalization. The book also discusses: Different materials and platforms used to develop biomicrosystems Various biological entities and pathogens (in ascending order of complexity) The multidisciplinary aspects of engineering bioactive surfaces Engineering perspectives, including methods of manufacturing bioactive surfaces and devices Microfluidics modeling and experimentation Device level implementation of BioMEMS concepts for different applications. Because BioMEMS is an application-driven field, the book also highlights the concepts of lab-on-a-chip (LOC) and micro total analysis system (μTAS), along with their pertinence to the emerging point-of-care (POC) and point-of-need (PON) applications

    EUROSENSORS XVII : book of abstracts

    Get PDF
    Fundação Calouste Gulbenkien (FCG).Fundação para a Ciência e a Tecnologia (FCT)

    Electrochemical Plug-and-Power e-readers for Point-of-Care Applications

    Get PDF
    Point-of-Care diagnostic tests enable monitor health conditions and obtain fast results close to the patient, reducing medical costs, and allowing the control of infectious outbreaks. The interest in developing Point-of-Care devices is increasing due to they are suitable for a wide variety of applications. This doctoral thesis focuses on the development of Plug-and-Power electronic readers (e- readers) for electrochemical detections and the demonstration of their possibilities as Point-of-Care diagnostic testing. The solutions proposed in this study make it possible to improve Point-of-Care tests whose premises are laboratory decentralization, personalized medicine, rapid diagnosis, and improvement of patient care. Developed electronic readers can be powered from a conventional system, such as a USB port or a lithium battery, or can be defined as self-powered systems, capable of extracting energy from alternative energy sources, such as fuel cells, defining Plug-and-Power systems. The designed electrochemical detection devices in this thesis are based on low-power consumption electronic instrumentation circuits. These circuits are capable of controlling the sensing element, measuring its response, and representing the result quantitatively. The implemented devices can work with both electrochemical sensors and fuel cells. Furthermore, it is possible to adapt its measurement range, enabling its use in a wide variety of applications. Thanks to their reduced energy consumption, some of these developments can be defined as self-powered platforms able to operate only with the energy extracted from the biological sample, which in turn is monitored. These devices are easy-to-use and plug-and-play, enabling those unskilled individuals to carry out tests after prior training. Moreover, thanks to their user-friendly interface, results are clear and easy to understand. This doctoral dissertation is presented as an article compendium and composed of three publications detailed in chronological order of publication. The first contribution describes an innovative portable Point-of-Care device able to provide a quantitative result of the glucose concentration of a sample. The proposed system combines an e-reader and a disposable device based on two elements: a glucose paper-based power source, and a glucose fuel cell-based sensor. The battery-less e-reader extracts the energy from the disposable unit, acquires the signal, processes it, and shows the glucose concentration on a numerical display. Due to low-power consumption of the e-reader, the whole electronic system can operate only with the energy extracted from the disposable element. Furthermore, the proposed system minimizes the user interaction, which only must deposit the sample on the strip and wait a few seconds to see the test result. The second publication validates the e-reader in other scenarios following two approaches: using fuel cells as a power element, and as a dual powering and sensing element. The device was tested with glucose, urine, methanol, and ethanol fuel cells and electrochemical sensors in order to show the adaptability of this versatile concept to a wide variety of fields beyond clinical diagnostics, such as veterinary or environmental fields. The third study presents a low-cost, miniaturized, and customizable electronic reader for amperometric detections. The USB-powered portable device is composed of a full- custom electronic board for signal acquisition, and software, which controls the systems, represents and saves the results. In this study, the performance of the device was compared against three commercial potentiostats, showing comparable results to those obtained using three commercial systems, which were significantly more expensive. As proof of concept, the system was validated by detecting horseradish peroxidase samples. However, it could be easily extended its scope and measure other types of analytes or biological matrices since it can be easily adapted to detect currents a wide range of currents.Las pruebas de diagnostico Point-of-Care permiten monitorizar las condiciones de salud y obtener resultados rápidos cerca del paciente, reduciendo los costes médicos y permitiendo controlar brotes infecciosos. El interés por desarrollar dispositivos de Point- of-Care está aumentando debido a que son aplicables a una amplia variedad de aplicaciones. Esta tesis doctoral se centra en el desarrollo de lectores electrónicos (e-readers) Plug-and- Power para detecciones electroquímicas y la demostración de sus posibilidades como pruebas de diagnóstico de punto de atención (Point-of-Care). Las soluciones propuestas en este trabajo permiten mejorar las pruebas Point-of-Care, cuyas premisas son la descentralización de laboratorio, la medicina personalizada, el diagnóstico rápido y la mejora de la atención al paciente. Los lectores electrónicos desarrollados pueden ser alimentados desde un sistema convencional, como puede ser un puerto USB o una batería de litio, o definirse como sistemas autoalimentados, capaces de extraen energía de fuentes alternativas de energía, como celdas de combustible (fuel cells), definiendo así sistemas Plug-and-Power. Los dispositivos de detección electroquímica diseñados se basan en circuitos de instrumentación electrónica de bajo consumo. Estos circuitos son capaces controlar el elemento de sensado, medir su respuesta y representar el resultado de forma cuantitativa. Los dispositivos implementados pueden trabajar tanto con sensores electroquímicos como con fuel cells. Además, es posible adaptar su rango de medida, permitiendo su utilización en una amplia variedad de aplicaciones. Gracias a su reducido consumo de energía, algunos de estos desarrollos pueden definirse como plataformas autoalimentadas capaces de operar solo con la energía extraída de la muestra biológica, que a su vez es monitorizada. Estas plataformas electrónicas son fáciles de usar y Plug-and-Play, permitiendo que personas no cualificadas puedan utilizarlas después de un previo entrenamiento. Además, gracias a su interfaz fácil de usar, los resultados son claros y fáciles de interpretar

    Self-powered mobile sensor for in-pipe potable water quality monitoring

    Get PDF
    Traditional stationary sensors for potable-water quality monitoring in a wireless sensor network format allow for continuous data collection and transfer. These stationary sensors have played a key role in reporting contamination events in order to secure public health. We are developing a self-powered mobile sensor that can move with the water flow, allowing real-time detection of contamination in water distribution pipes, with a higher temporal resolution. Functionality of the mobile sensor was tested for detecting and monitoring pH, Ca2+, Mg2+, HCO3-/CO32-, NH4+, and Clions. Moreover, energy harvest and wireless data transmission capabilities are being designed for the mobile sensor

    Micro/nanofluidic and lab-on-a-chip devices for biomedical applications

    Get PDF
    Micro/Nanofluidic and lab-on-a-chip devices have been increasingly used in biomedical research [1]. Because of their adaptability, feasibility, and cost-efficiency, these devices can revolutionize the future of preclinical technologies. Furthermore, they allow insights into the performance and toxic effects of responsive drug delivery nanocarriers to be obtained, which consequently allow the shortcomings of two/three-dimensional static cultures and animal testing to be overcome and help to reduce drug development costs and time [2–4]. With the constant advancements in biomedical technology, the development of enhanced microfluidic devices has accelerated, and numerous models have been reported. Given the multidisciplinary of this Special Issue (SI), papers on different subjects were published making a total of 14 contributions, 10 original research papers, and 4 review papers. The review paper of Ko et al. [1] provides a comprehensive overview of the significant advancements in engineered organ-on-a-chip research in a general way while in the review presented by Kanabekova and colleagues [2], a thorough analysis of microphysiological platforms used for modeling liver diseases can be found. To get a summary of the numerical models of microfluidic organ-on-a-chip devices developed in recent years, the review presented by Carvalho et al. [5] can be read. On the other hand, Maia et al. [6] report a systematic review of the diagnosis methods developed for COVID-19, providing an overview of the advancements made since the start of the pandemic. In the following, a brief summary of the research papers published in this SI will be presented, with organs-on-a-chip, microfluidic devices for detection, and device optimization having been identified as the main topics.info:eu-repo/semantics/publishedVersio
    corecore