1,280 research outputs found

    Turbo-FLASH based arterial spin labeled perfusion MRI at 7 T.

    Get PDF
    Motivations of arterial spin labeling (ASL) at ultrahigh magnetic fields include prolonged blood T1 and greater signal-to-noise ratio (SNR). However, increased B0 and B1 inhomogeneities and increased specific absorption ratio (SAR) challenge practical ASL implementations. In this study, Turbo-FLASH (Fast Low Angle Shot) based pulsed and pseudo-continuous ASL sequences were performed at 7T, by taking advantage of the relatively low SAR and short TE of Turbo-FLASH that minimizes susceptibility artifacts. Consistent with theoretical predictions, the experimental data showed that Turbo-FLASH based ASL yielded approximately 4 times SNR gain at 7T compared to 3T. High quality perfusion images were obtained with an in-plane spatial resolution of 0.85×1.7 mm(2). A further functional MRI study of motor cortex activation precisely located the primary motor cortex to the precentral gyrus, with the same high spatial resolution. Finally, functional connectivity between left and right motor cortices as well as supplemental motor area were demonstrated using resting state perfusion images. Turbo-FLASH based ASL is a promising approach for perfusion imaging at 7T, which could provide novel approaches to high spatiotemporal resolution fMRI and to investigate the functional connectivity of brain networks at ultrahigh field

    Quantitative Analysis of Arterial Spin Labeling FMRI Data Using a General Linear Model

    Get PDF
    Arterial spin labeling techniques can yield quantitative measures of perfusion by fitting a kinetic model to difference images (tagged-control). Because of the noisy nature of the difference images investigators typically average a large number of tagged versus control difference measurements over long periods of time. This averaging requires that the perfusion signal be at a steady state and not at the transitions between active and baseline states in order to quantitatively estimate activation induced perfusion. This can be an impediment for functional magnetic resonance imaging task experiments. In this work, we introduce a general linear model (GLM) that specifies Blood Oxygenation Level Dependent (BOLD) effects and arterial spin labeling modulation effects and translate them into meaningful, quantitative measures of perfusion by using standard tracer kinetic models. We show that there is a strong association between the perfusion values using our GLM method and the traditional subtraction method, but that our GLM method is more robust to noise

    Drug and disease effects on the human brain studied by functional MRI

    Get PDF
    Background: With the advent of magnetic resonance imaging (MRI) technology, various functional MRI (fMRI) techniques have become available for non-invasive neuroscientific studies and clinical diagnostics, which have led to a better understanding of the human brain function in normal and diseased subjects. In order to interpret the fMRI results correctly and design optimal research studies it is important to understand both the potentials and limitations associated with each fMRI technique. In this thesis we used two fMRI techniques: arterial spin labeling (ASL) and resting-sate BOLD (blood-oxygen-level dependent) fMRI to study the effects of a CNS-active (central nervous system) drug and neurologic disorder on the human brain function. Purpose: The main research purposes of this thesis are the following: 1) We assess the reproducibility and reliability of rCBF (regional cerebral blood flow) measurements conducted at 3T with pCASL (pseudo continuous ASL) technique; 2) We study the pharmacokinetics of a CNS active drug in normal volunteers by conducting rCBF measurements as a function of time after intake of a single dose of 20 mg d-amphetamine with the pCASL technique; 3) We investigate the possible neurological abnormalities of mild traumatic brain injury (mTBI) patients with chronic fatigue by performing rCBF and resting-sate functional connectivity measurements before, during and after a 20 minute continuous psychomotor vigilance task (PVT). Conclusion: The results from these studies show that the pCASL technique is a relatively robust method for quantitative measurements of rCBF in both normal volunteers and patient subjects. Repeated rCBF measurements with the pCASL method is a non-invasive and sufficiently sensitive approach to assess pharmacokinetic response to CNS active chemicals and should be useful for studying the neurophysiological characteristics in vivo of potential CNS drugs. The results from the mTBI subjects demonstrate that the repeated measurements of rCBF and functional connectivity metrics before, during and after a PVT provide sensitive diagnostic imaging methods to assess neurological abnormality of mTBI patients without apparent neuroanatomical damage. In addition to the clinical diagnostic value, these studies also contribute to important knowledge for the design and analysis of brain functional imaging studies of drugs and neurological diseases

    Supporting measurements or more averages? How to quantify cerebral blood flow most reliably in 5 minutes by arterial spin labeling

    Get PDF
    Purpose To determine whether sacrificing part of the scan time of pseudo-continuous arterial spin labeling (PCASL) for measurement of the labeling efficiency and blood T1 is beneficial in terms of CBF quantification reliability. Methods In a simulation framework, 5-minute scan protocols with different scan time divisions between PCASL data acquisition and supporting measurements were evaluated in terms of CBF estimation variability across both noise and ground truth parameter realizations taken from the general population distribution. The entire simulation experiment was repeated for a single-post-labeling delay (PLD), multi-PLD, and free-lunch time-encoded (te-FL) PCASL acquisition strategy. Furthermore, a real data study was designed for preliminary validation. Results For the considered population statistics, measuring the labeling efficiency and the blood T1 proved beneficial in terms of CBF estimation variability for any distribution of the 5-minute scan time compared to only acquiring ASL data. Compared to single-PLD PCASL without support measurements as recommended in the consensus statement, a 26%, 33%, and 42% reduction in relative CBF estimation variability was found for optimal combinations of supporting measurements with single-PLD, free-lunch, and multi-PLD PCASL data acquisition, respectively. The benefit of taking the individual variation of blood T1 into account was also demonstrated in the real data experiment. Conclusions Spending time to measure the labeling efficiency and the blood T1 instead of acquiring more averages of the PCASL data proves to be advisable for robust CBF quantification in the general population

    Functional Evaluation of the Peripheral Vasculature Using Magnetic Resonance Imaging

    Get PDF
    Akin to cardiac stress testing, functional integrity of the peripheral vasculature can be interrogated by measuring the response to a stimulus. Recent reports suggest that the reactive hyperemia response, the physiologic reaction following induced ischemia, is associated with disease presence, correlated with disease severity, and may be a sensitive biomarker of pre-clinical disease. In this dissertation, an innovative, interleaved magnetic resonance imaging method is developed, termed Perfusion, Intravascular Venous Oxygen saturation, and T2* (PIVOT), which simultaneously measures microvascular perfusion, venous oxygen saturation (SvO2), and the blood-oxygen-level dependent (BOLD) signal. PIVOT is first applied in healthy subjects to demonstrate its ability to measure reactive hyperemia response dynamics. Next, reactive hyperemia perfusion is compared between the more temporally efficient pulsed arterial spin labeling (PASL) used in PIVOT and the more recently developed and preferred method for the brain, pseudo-continuous ASL (pCASL). Assessment of the impact of blood flow variability throughout the ischemia-reperfusion paradigm on pCASL perfusion quantification is investigated. Then, both PASL and pCASL sequences are used to measure reactive hyperemia perfusion in healthy subjects. No significant differences were detected between perfusion measured with PASL or pCASL despite different labeling strategies, temporal resolutions, and perfusion quantification models. Subsequently, PIVOT is combined with a velocity-encoded dual-echo GRE to create an interleaved three-slice sequence that provides quantification of bulk blood flow in the arteries and veins in addition to the traditional PIVOT measures. This new sequence, termed Velocity and PIVOT (vPIVOT) is used to investigate the relationship of blood flow in the macro- and microvasculature and muscle oxygen consumption during the transition from exercise to rest. Finally, PIVOT is applied clinically in a cohort of patients with varying degrees of severity of peripheral artery disease. Increasing disease severity was correlated with a prolongation of the hyperemic response time, measured as a lengthening of time to peak perfusion, SvO2 washout time, and time to peak T2*. In addition, peak perfusion and SvO2 upslope were significantly different between patients with PAD and healthy controls. These results suggest the potential for PIVOT to evaluate disease severity and may present a tool to assess response to therapeutic intervention

    Quantification of cerebral perfusion and cerebrovascular reserve using Turbo‐QUASAR arterial spin labeling MRI

    Get PDF
    PurposeTo compare cerebral blood flow (CBF) and cerebrovascular reserve (CVR) quantification from Turbo‐QUASAR (quantitative signal targeting with alternating radiofrequency labeling of arterial regions) arterial spin labeling (ASL) and single post‐labeling delay pseudo‐continuous ASL (PCASL).MethodsA model‐based method was developed to quantify CBF and arterial transit time (ATT) from Turbo‐QUASAR, including a correction for magnetization transfer effects caused by the repeated labeling pulses. Simulations were performed to assess the accuracy of the model‐based method. Data from an in vivo experiment conducted on a healthy cohort were retrospectively analyzed to compare the CBF and CVR (induced by acetazolamide) measurement from Turbo‐QUASAR and PCASL on the basis of global and regional differences. The quality of the two ASL data sets was examined using the coefficient of variation (CoV).ResultsThe model‐based method for Turbo‐QUASAR was accurate for CBF estimation (relative error was 8% for signal‐to‐noise ratio = 5) in simulations if the bolus duration was known. In the in vivo experiment, the mean global CVR estimated by Turbo‐QUASAR and PCASL was between 63% and 64% and not significantly different. Although global CBF values of the two ASL techniques were not significantly different, regional CBF differences were found in deep gray matter in both pre‐ and postacetazolamide conditions. The CoV of Turbo‐QUASAR data was significantly higher than PCASL.ConclusionBoth ASL techniques were effective for quantifying CBF and CVR, despite the regional differences observed. Although CBF estimated from Turbo‐QUASAR demonstrated a higher variability than PCASL, Turbo‐QUASAR offers the advantage of being able to measure and control for variation in ATT

    ExploreASL: An image processing pipeline for multi-center ASL perfusion MRI studies

    Get PDF
    Arterial spin labeling (ASL) has undergone significant development since its inception, with a focus on improving standardization and reproducibility of its acquisition and quantification. In a community-wide effort towards robust and reproducible clinical ASL image processing, we developed the software package ExploreASL, allowing standardized analyses across centers and scanners. The procedures used in ExploreASL capitalize on published image processing advancements and address the challenges of multi-center datasets with scanner-specific processing and artifact reduction to limit patient exclusion. ExploreASL is self-contained, written in MATLAB and based on Statistical Parameter Mapping (SPM) and runs on multiple operating systems. To facilitate collaboration and data-exchange, the toolbox follows several standards and recommendations for data structure, provenance, and best analysis practice. ExploreASL was iteratively refined and tested in the analysis of >10,000 ASL scans using different pulse-sequences in a variety of clinical populations, resulting in four processing modules: Import, Structural, ASL, and Population that perform tasks, respectively, for data curation, structural and ASL image processing and quality control, and finally preparing the results for statistical analyses on both single-subject and group level. We illustrate ExploreASL processing results from three cohorts: perinatally HIV-infected children, healthy adults, and elderly at risk for neurodegenerative disease. We show the reproducibility for each cohort when processed at different centers with different operating systems and MATLAB versions, and its effects on the quantification of gray matter cerebral blood flow. ExploreASL facilitates the standardization of image processing and quality control, allowing the pooling of cohorts which may increase statistical power and discover between-group perfusion differences. Ultimately, this workflow may advance ASL for wider adoption in clinical studies, trials, and practice

    Distribution of cerebral blood flow in the caudate nucleus, lentiform nucleus and thalamus in patients with carotid artery stenosis

    Get PDF
    To investigate the influence of internal carotid artery (ICA) stenosis on the distribution of blood flow to the caudate nucleus, lentiform nucleus, and thalamus. We studied 18 healthy control subjects, 20 patients with a unilateral asymptomatic ICA stenosis, and 15 patients with a recently symptomatic unilateral ICA stenosis. The contribution of the ICAs and the basilar artery to the perfusion of the deep brain structures was assessed by perfusion territory selective arterial spin labeling (ASL) MRI. Differences were tested with a two-tailed Fishers' exact test. The caudate nucleus was predominantly supplied with blood by the ipsilateral ICA in all groups. In 4 of the 15 (27%) the symptomatic patients, the caudate nucleus partially received blood from the contralateral ICA, compared to none of the 18 healthy control subjects (p = 0.03). The lentiform nucleus and the thalamus were predominantly supplied with blood by the ipsilateral ICA and basilar artery respectively in all groups. In patients with a symptomatic ICA stenosis, the caudate nucleus may be supplied with blood by the contralateral ICA more often than in healthy controls.Neuro Imaging Researc
    corecore