26,637 research outputs found
Communication channel analysis and real time compressed sensing for high density neural recording devices
Next generation neural recording and Brain-
Machine Interface (BMI) devices call for high density or distributed
systems with more than 1000 recording sites. As the
recording site density grows, the device generates data on the
scale of several hundred megabits per second (Mbps). Transmitting
such large amounts of data induces significant power
consumption and heat dissipation for the implanted electronics.
Facing these constraints, efficient on-chip compression techniques
become essential to the reduction of implanted systems power
consumption. This paper analyzes the communication channel
constraints for high density neural recording devices. This paper
then quantifies the improvement on communication channel
using efficient on-chip compression methods. Finally, This paper
describes a Compressed Sensing (CS) based system that can
reduce the data rate by > 10x times while using power on
the order of a few hundred nW per recording channel
Green compressive sampling reconstruction in IoT networks
In this paper, we address the problem of green Compressed Sensing (CS) reconstruction within Internet of Things (IoT) networks, both in terms of computing architecture and reconstruction algorithms. The approach is novel since, unlike most of the literature dealing with energy efficient gathering of the CS measurements, we focus on the energy efficiency of the signal reconstruction stage given the CS measurements. As a first novel contribution, we present an analysis of the energy consumption within the IoT network under two computing architectures. In the first one, reconstruction takes place within the IoT network and the reconstructed data are encoded and transmitted out of the IoT network; in the second one, all the CS measurements are forwarded to off-network devices for reconstruction and storage, i.e., reconstruction is off-loaded. Our analysis shows that the two architectures significantly differ in terms of consumed energy, and it outlines a theoretically motivated criterion to select a green CS reconstruction computing architecture. Specifically, we present a suitable decision function to determine which architecture outperforms the other in terms of energy efficiency. The presented decision function depends on a few IoT network features, such as the network size, the sink connectivity, and other systems’ parameters. As a second novel contribution, we show how to overcome classical performance comparison of different CS reconstruction algorithms usually carried out w.r.t. the achieved accuracy. Specifically, we consider the consumed energy and analyze the energy vs. accuracy trade-off. The herein presented approach, jointly considering signal processing and IoT network issues, is a relevant contribution for designing green compressive sampling architectures in IoT networks
ECG Signal Reconstruction on the IoT-Gateway and Efficacy of Compressive Sensing Under Real-time Constraints
Remote health monitoring is becoming indispensable, though, Internet of Things (IoTs)-based solutions have many implementation challenges, including energy consumption at the sensing node, and delay and instability due to cloud computing. Compressive sensing (CS) has been explored as a method to extend the battery lifetime of medical wearable devices. However, it is usually associated with computational complexity at the decoding end, increasing the latency of the system. Meanwhile, mobile processors are becoming computationally stronger and more efficient. Heterogeneous multicore platforms (HMPs) offer a local processing solution that can alleviate the limitations of remote signal processing. This paper demonstrates the real-time performance of compressed ECG reconstruction on ARM's big.LITTLE HMP and the advantages they provide as the primary processing unit of the IoT architecture. It also investigates the efficacy of CS in minimizing power consumption of a wearable device under real-time and hardware constraints. Results show that both the orthogonal matching pursuit and subspace pursuit reconstruction algorithms can be executed on the platform in real time and yield optimum performance on a single A15 core at minimum frequency. The CS extends the battery life of wearable medical devices up to 15.4% considering ECGs suitable for wellness applications and up to 6.6% for clinical grade ECGs. Energy consumption at the gateway is largely due to an active internet connection; hence, processing the signals locally both mitigates system's latency and improves gateway's battery life. Many remote health solutions can benefit from an architecture centered around the use of HMPs, a step toward better remote health monitoring systems.Peer reviewedFinal Published versio
Optimizing Wirelessly Powered Crowd Sensing: Trading energy for data
To overcome the limited coverage in traditional wireless sensor networks,
\emph{mobile crowd sensing} (MCS) has emerged as a new sensing paradigm. To
achieve longer battery lives of user devices and incentive human involvement,
this paper presents a novel approach that seamlessly integrates MCS with
wireless power transfer, called \emph{wirelessly powered crowd sensing} (WPCS),
for supporting crowd sensing with energy consumption and offering rewards as
incentives. The optimization problem is formulated to simultaneously maximize
the data utility and minimize the energy consumption for service operator, by
jointly controlling wireless-power allocation at the \emph{access point} (AP)
as well as sensing-data size, compression ratio, and sensor-transmission
duration at \emph{mobile sensor} (MS). Given the fixed compression ratios, the
optimal power allocation policy is shown to have a \emph{threshold}-based
structure with respect to a defined \emph{crowd-sensing priority} function for
each MS. Given fixed sensing-data utilities, the compression policy achieves
the optimal compression ratio. Extensive simulations are also presented to
verify the efficiency of the contributed mechanisms.Comment: arXiv admin note: text overlap with arXiv:1711.0206
e-SAFE: Secure, Efficient and Forensics-Enabled Access to Implantable Medical Devices
To facilitate monitoring and management, modern Implantable Medical Devices
(IMDs) are often equipped with wireless capabilities, which raise the risk of
malicious access to IMDs. Although schemes are proposed to secure the IMD
access, some issues are still open. First, pre-sharing a long-term key between
a patient's IMD and a doctor's programmer is vulnerable since once the doctor's
programmer is compromised, all of her patients suffer; establishing a temporary
key by leveraging proximity gets rid of pre-shared keys, but as the approach
lacks real authentication, it can be exploited by nearby adversaries or through
man-in-the-middle attacks. Second, while prolonging the lifetime of IMDs is one
of the most important design goals, few schemes explore to lower the
communication and computation overhead all at once. Finally, how to safely
record the commands issued by doctors for the purpose of forensics, which can
be the last measure to protect the patients' rights, is commonly omitted in the
existing literature. Motivated by these important yet open problems, we propose
an innovative scheme e-SAFE, which significantly improves security and safety,
reduces the communication overhead and enables IMD-access forensics. We present
a novel lightweight compressive sensing based encryption algorithm to encrypt
and compress the IMD data simultaneously, reducing the data transmission
overhead by over 50% while ensuring high data confidentiality and usability.
Furthermore, we provide a suite of protocols regarding device pairing,
dual-factor authentication, and accountability-enabled access. The security
analysis and performance evaluation show the validity and efficiency of the
proposed scheme
Optimal Compression and Transmission Rate Control for Node-Lifetime Maximization
We consider a system that is composed of an energy constrained sensor node
and a sink node, and devise optimal data compression and transmission policies
with an objective to prolong the lifetime of the sensor node. While applying
compression before transmission reduces the energy consumption of transmitting
the sensed data, blindly applying too much compression may even exceed the cost
of transmitting raw data, thereby losing its purpose. Hence, it is important to
investigate the trade-off between data compression and transmission energy
costs. In this paper, we study the joint optimal compression-transmission
design in three scenarios which differ in terms of the available channel
information at the sensor node, and cover a wide range of practical situations.
We formulate and solve joint optimization problems aiming to maximize the
lifetime of the sensor node whilst satisfying specific delay and bit error rate
(BER) constraints. Our results show that a jointly optimized
compression-transmission policy achieves significantly longer lifetime (90% to
2000%) as compared to optimizing transmission only without compression.
Importantly, this performance advantage is most profound when the delay
constraint is stringent, which demonstrates its suitability for low latency
communication in future wireless networks.Comment: accepted for publication in IEEE Transactions on Wireless
Communicaiton
- …