    A Review on Power Quality Improvement via Custom Power Devices

    Full text link
    Power Quality has been said a set of electrical boundaries of the electrical supply provided under normal operating condition that allow equipment to function in its rated condition without significant loss of performance and life expectancy that do not disturb or disrupt the consumers\u27 process. Performance degradation results when the electrical power supplied to equipment is deficient. Thus power quality improvement is the main concern of present era. The problems of power quality are rising exponentially from the last few decades due to the rising demand for power and the need for their improvement is indeed a big question. The main power quality problems such as voltage sags and swells, power interruptions (short and long), voltage spike, harmonic distortion, noise have led to financial losses. To avoid huge losses and to overcome the above mentioned problems, power electronics has evolved with its new types of devices known as Custom Power Devices which are being reviewed in this paper

    Design Optimization of Inductive Power Transfer Systems for Contactless Electric Vehicle Charging Applications

    Get PDF
    Contactless Electric Vehicle (EV) charging based on magnetic resonant induction is an emerging technology that can revolutionize the future of the EV industry and transportation systems by enabling an automated and convenient charging process. However, in order to make this technology an acceptable alternative for conventional plug-in charging systems it needs to be optimized for different design measures. Specifically, the efficiency of an inductive EV charging system is of a great importance and should be comparable to the efficiency of conventional plug-in EV chargers. The aim of this study is to develop solutions that contribute to the design enhancement of inductive EV charging systems. Specifically, generalized physics-based design optimization methods that address the trade-off problem between several key objectives including efficiency, power density, misalignment tolerance, and cost efficiency considering critical constraints are developed. Using the developed design methodology, a 3.7kW inductive charging system with square magnetic structures is investigated as a case study and a prototype is built to validate the optimization results. The developed prototype achieves 93.65% efficiency (DC-to-DC) and a power density of 1.65kW/dm3. Also, self-tuning power transfer control methods with resonance frequency tracking capability and bidirectional power transfer control are presented. The proposed control methods enhance the efficiency of power converters and reduce the Electromagnetic Interference (EMI) by enabling soft-switching operations. Several simplified digital controllers are developed and experimentally implemented. The controllers are implemented without the use of DSP/FPGA solutions. Experimental tests show that of the developed simplified controllers can effectively regulate the power transfer around the desired value. Moreover, the experiments show that compared to conventional converters, the developed converters can achieve 4% higher efficiency at low power levels. Moreover, enhanced matrix converter topologies that can achieve bidirectional power transfer and high efficiency with a reduced number of switching elements are introduced. The self-tuning controllers are utilized to design and develop control schemes for bidirectional power transfer regulation. The simulation analyses and experimental results show that the developed matrix converters can effectively establish bidirectional power transfer at the desired power levels with soft-switching operations and resonance frequency tracking capability. Specifically, a direct three-phase AC-AC matrix converter with a reduced number of switches (only seven) is developed and built. It is shown that the developed converters can achieve efficiencies as high as 98.54% at high power levels and outperform conventional two-stage converters

    Analysis, Design and Control of a Modular Full-Si Converter Concept for Electric Vehicle Ultra-Fast Charging

    Get PDF
    L'abstract è presente nell'allegato / the abstract is in the attachmen

    Efficacy of Smart PV Inverter as a Strategic Mitigator of Network Harmonic Resonance and a Suppressor of Temporary Overvoltage Phenomenon in Distribution Systems

    Get PDF
    The research work explores the design of Smart PV inverters in terms of modelling and investigates the efficacy of a Smart PV inverter as a strategic mitigator of network harmonic resonance phenomenon and a suppressor of Temporary Overvoltage (TOV) in distribution systems. The new application and the control strategy of Smart PV inverters can also be extended to SmartPark-Plug in Electric Vehicles as the grid becomes smarter. As the grid is becoming smarter, more challenges are encountered with the integration of PV plants in distribution systems. Smart PV inverters nowadays are equipped with specialized controllers for exchanging reactive power with the grid based on the available capacity of the inverter, after the real power generation. Although present investigators are researching on several applications of Smart PV inverters, none of the research-work in real time and in documentation have addressed the benefits of employing Smart PV inverters to mitigate network resonances. U.S based standard IEEE 519 for power quality describes the network resonance as a major contributor that has an impact on the harmonic levels. This dissertation proposes a new application for the first time in utilizing a Smart PV inverter to act as a virtual detuner in mitigating network resonance. As a part of the Smart PV inverter design, the LCL filter plays a vital role on network harmonic resonance and further has a direct impact on the stability of the controller and rest of the distribution system. Temporary Overvoltage (TOV) phenomenon is more pronounced especially during unbalanced faults like single line to ground faults (SLGF) in the presence of PV. Such an abnormal incident can damage the customer loads. IEEE 142-“Effective grounding” technique is employed to design the grounding scheme for synchronous based generators. The utilities have been trying to make a PV system comply with IEEE 142 standard as well. Several utilities are still employing the same grounding schemes even now. The attempt has resulted in diminishing the efficacy of protection schemes. Further, millions of dollars and power has been wasted by the utilities. As a result, the concept of effective grounding for PV system has become a challenge when utilities try to mitigate TOV. With an intention of economical aspects in distribution systems planning, this dissertation also proposes a new application and a novel control scheme for utilizing Smart PV/Smart Park inverters to mitigate TOV in distribution systems for the first time. In other words, this novel application can serve as an effective and supporting schema towards ineffective grounding systems. PSCAD/EMTDC has been used throughout the course of research. The idea of Smart inverters serving as a virtual detuner in mitigating network harmonic resonance and as a TOV suppressor in distribution systems has been devised based on the basic principle of VAR injection and absorption with a new control strategy respectively. This research would further serve as a pioneering approach for researchers and planning engineers working in distribution systems

    Multi-Level Medium Voltage Inverter for Dc Distributed Wind Farm to Establish Grid Interface and Provide Ancillary Support

    Get PDF
    Wind energy has gained in popularity in recent years due to cost, security and environmental concerns associated with conventional energy sources like fossil fuels. However, the utilization of wind energy in power systems creates many technical and non-technical challenges that need to be addressed for successful integrations. The main technical issues related to wind energy are its uncertainty and variability and their impacts on stability, reliability and quality of the electric power. In systems with high wind energy penetrations, unlike conventional generations, sudden changes in active and/or reactive power demand cannot be supported by wind energy. This lack of demand support may create unwanted voltage and frequency variations in the grid. On the hand, the existing AC distributed wind farms have several drawbacks including complexity, higher cost, and lower efficiency. In this dissertation, a medium voltage direct current (MVDC) distribution system for wind farms is investigated. The proposed system offers higher reliability, lower cost, higher efficiency and more importantly grid support. It also allows for easier integration of energy storage systems at DC level. Design, control, implementation, and testing of a three-level medium voltage inverter are presented. The inverter can provide active and reactive power support to the grid in case of frequency and voltage droops. Simulation and experimental results are presented to verify the viability of the proposed system and control techniques

    Summary of State-of-the-Art Power Conversion Systems for Energy Storage Applications

    Full text link

    Cooperative Control of Multi-Master-Slave Islanded Microgrid with Power Quality Enhancement Based on Conservative Power Theory

    Get PDF
    Made available in DSpace on 2018-11-26T16:04:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2018-07-01Cooperative control of power converters in a microgrid offers power quality enhancement at sensitive load buses. Such cooperation is particularly important in the presence of reactive, nonlinear, and unbalanced loads. In this paper, a multi-master-slave-based control of distributed generators interface converters in a three-phase four-wire islanded microgrid using the conservative power theory (CPT) is proposed. Inverters located in close proximity operate as a group in master- salve mode. Slaves inject the available energy and compensate selectively unwanted current components of local loads with the secondary effect of having enhanced voltage waveforms while masters share the remaining load power autonomously with distant groups using frequency droop. The close proximity makes it practical for control signals to be communicated between inverters in one group with the potential to provide rapid load sharing response for mitigation of undesirable current components. Since each primary source has its own constraints, a supervisory control is considered for each group to determine convenient sharing factors. The CPT decompositions provide decoupled current and power references in abc-frame, resulting in a selective control strategy able to share each current component with desired percentage among the microgrid inverters. Simulation results are presented to demonstrate the effectiveness of the proposed method.Colorado Sch Mines, Dept EECS, Golden, CO 80401 USAAalborg Univ, Dept Energy Technol, DK-9220 Aalborg, DenmarkPetr Inst, Dept Elect Engn, Abu Dhabi 2533, U Arab Emirate

    Full body harness

    Get PDF
    The full body safety harness is a key part of an active fall arrest system. The harness serves two purposes, first, distributing fall forces safely across a worker's body in the event of a free fall, and second, providing freedom of movement sufficient to allow the worker to effectively perform his or her job. The complete body harness incorporates the characteristics of a sit harness that supports the hips and upper legs as well as a chest harness that supports the chest and shoulders. The complete body structure includes the human torso when correctly used and helps to keep it upright during a fall case
    • …