4 research outputs found
Snake-Like Robots for Minimally Invasive, Single Port, and Intraluminal Surgeries
The surgical paradigm of Minimally Invasive Surgery (MIS) has been a key
driver to the adoption of robotic surgical assistance. Progress in the last
three decades has led to a gradual transition from manual laparoscopic surgery
with rigid instruments to robot-assisted surgery. In the last decade, the
increasing demand for new surgical paradigms to enable access into the anatomy
without skin incision (intraluminal surgery) or with a single skin incision
(Single Port Access surgery - SPA) has led researchers to investigate
snake-like flexible surgical devices. In this chapter, we first present an
overview of the background, motivation, and taxonomy of MIS and its newer
derivatives. Challenges of MIS and its newer derivatives (SPA and intraluminal
surgery) are outlined along with the architectures of new snake-like robots
meeting these challenges. We also examine the commercial and research surgical
platforms developed over the years, to address the specific functional
requirements and constraints imposed by operations in confined spaces. The
chapter concludes with an evaluation of open problems in surgical robotics for
intraluminal and SPA, and a look at future trends in surgical robot design that
could potentially address these unmet needs.Comment: 41 pages, 18 figures. Preprint of article published in the
Encyclopedia of Medical Robotics 2018, World Scientific Publishing Company
www.worldscientific.com/doi/abs/10.1142/9789813232266_000
Modeling, Analysis, Force Sensing and Control of Continuum Robots for Minimally Invasive Surgery
This dissertation describes design, modeling and application of continuum robotics for surgical applications, specifically parallel continuum robots (PCRs) and concentric tube manipulators (CTMs). The introduction of robotics into surgical applications has allowed for a greater degree of precision, less invasive access to more remote surgical sites, and user-intuitive interfaces with enhanced vision systems. The most recent developments have been in the space of continuum robots, whose exible structure create an inherent safety factor when in contact with fragile tissues. The design challenges that exist involve balancing size and strength of the manipulators, controlling the manipulators over long transmission pathways, and incorporating force sensing and feedback from the manipulators to the user.
Contributions presented in this work include: (1) prototyping, design, force sensing, and force control investigations of PCRs, and (2) prototyping of a concentric tube manipulator for use in a standard colonoscope. A general kinetostatic model is presented for PCRs along with identification of multiple physical constraints encountered in design and construction. Design considerations and manipulator capabilities are examined in the form of matrix metrics and ellipsoid representations. Finally, force sensing and control are explored and experimental results are provided showing the accuracy of force estimates based on actuation force measurements and control capabilities.
An overview of the design requirements, manipulator construction, analysis and experimental results are provided for a CTM used as a tool manipulator in a traditional colonoscope. Currently, tools used in colonoscopic procedures are straight and exit the front of the scope with 1 DOF of operation (jaws of a grasper, tightening of a loop, etc.). This research shows that with a CTM deployed, the dexterity of these tools can be increased dramatically, increasing accuracy of tool operation, ease of use and safety of the overall procedure. The prototype investigated in this work allows for multiple tools to be used during a single procedure. Experimental results show the feasibility and advantages of the newly-designed manipulators
Cable-driven parallel mechanisms for minimally invasive robotic surgery
Minimally invasive surgery (MIS) has revolutionised surgery by providing faster recovery times, less post-operative complications, improved cosmesis and reduced pain for the patient. Surgical robotics are used to further decrease the invasiveness of procedures, by using yet smaller and fewer incisions or using natural orifices as entry point. However, many robotic systems still suffer from technical challenges such as sufficient instrument dexterity and payloads, leading to limited adoption in clinical practice. Cable-driven parallel mechanisms (CDPMs) have unique properties, which can be used to overcome existing challenges in surgical robotics. These beneficial properties include high end-effector payloads, efficient force transmission and a large configurable instrument workspace. However, the use of CDPMs in MIS is largely unexplored. This research presents the first structured exploration of CDPMs for MIS and demonstrates the potential of this type of mechanism through the development of multiple prototypes: the ESD CYCLOPS, CDAQS, SIMPLE, neuroCYCLOPS and microCYCLOPS. One key challenge for MIS is the access method used to introduce CDPMs into the body. Three different access methods are presented by the prototypes. By focusing on the minimally invasive access method in which CDPMs are introduced into the body, the thesis provides a framework, which can be used by researchers, engineers and clinicians to identify future opportunities of CDPMs in MIS. Additionally, through user studies and pre-clinical studies, these prototypes demonstrate that this type of mechanism has several key advantages for surgical applications in which haptic feedback, safe automation or a high payload are required. These advantages, combined with the different access methods, demonstrate that CDPMs can have a key role in the advancement of MIS technology.Open Acces
Proceedings of the Scientific-Practical Conference "Research and Development - 2016"
talent management; sensor arrays; automatic speech recognition; dry separation technology; oil production; oil waste; laser technolog