57 research outputs found

    Coding Strategies for Cochlear Implants Under Adverse Environments

    Get PDF
    Cochlear implants are electronic prosthetic devices that restores partial hearing in patients with severe to profound hearing loss. Although most coding strategies have significantly improved the perception of speech in quite listening conditions, there remains limitations on speech perception under adverse environments such as in background noise, reverberation and band-limited channels, and we propose strategies that improve the intelligibility of speech transmitted over the telephone networks, reverberated speech and speech in the presence of background noise. For telephone processed speech, we propose to examine the effects of adding low-frequency and high- frequency information to the band-limited telephone speech. Four listening conditions were designed to simulate the receiving frequency characteristics of telephone handsets. Results indicated improvement in cochlear implant and bimodal listening when telephone speech was augmented with high frequency information and therefore this study provides support for design of algorithms to extend the bandwidth towards higher frequencies. The results also indicated added benefit from hearing aids for bimodal listeners in all four types of listening conditions. Speech understanding in acoustically reverberant environments is always a difficult task for hearing impaired listeners. Reverberated sounds consists of direct sound, early reflections and late reflections. Late reflections are known to be detrimental to speech intelligibility. In this study, we propose a reverberation suppression strategy based on spectral subtraction to suppress the reverberant energies from late reflections. Results from listening tests for two reverberant conditions (RT60 = 0.3s and 1.0s) indicated significant improvement when stimuli was processed with SS strategy. The proposed strategy operates with little to no prior information on the signal and the room characteristics and therefore, can potentially be implemented in real-time CI speech processors. For speech in background noise, we propose a mechanism underlying the contribution of harmonics to the benefit of electroacoustic stimulations in cochlear implants. The proposed strategy is based on harmonic modeling and uses synthesis driven approach to synthesize the harmonics in voiced segments of speech. Based on objective measures, results indicated improvement in speech quality. This study warrants further work into development of algorithms to regenerate harmonics of voiced segments in the presence of noise

    A channel-selection criterion for suppressing reverberation in cochlear implants

    Get PDF
    This is the published version, also available here: http://dx.doi.org/10.1121/1.3559683.Little is known about the extent to which reverberation affects speech intelligibility by cochlear implant (CI) listeners. Experiment 1 assessed CI users’ performance using Institute of Electrical and Electronics Engineers (IEEE) sentences corrupted with varying degrees of reverberation. Reverberation times of 0.30, 0.60, 0.80, and 1.0 s were used. Results indicated that for all subjects tested, speech intelligibility decreased exponentially with an increase in reverberation time. A decaying-exponential model provided an excellent fit to the data. Experiment 2 evaluated (offline) a speech coding strategy for reverberation suppression using a channel-selection criterion based on the signal-to-reverberant ratio (SRR) of individual frequency channels. The SRR reflects implicitly the ratio of the energies of the signal originating from the early (and direct) reflections and the signal originating from the late reflections. Channels with SRR larger than a preset threshold were selected, while channels with SRR smaller than the threshold were zeroed out. Results in a highly reverberant scenario indicated that the proposed strategy led to substantial gains (over 60 percentage points) in speech intelligibility over the subjects’ daily strategy. Further analysis indicated that the proposed channel-selection criterion reduces the temporal envelope smearing effects introduced by reverberation and also diminishes the self-masking effects responsible for flattened formants

    Realising the head-shadow benefit to cochlear implant users

    Get PDF
    Cochlear implant (CI) users struggle to understand speech in noise. They suffer from elevated hearing thresholds and, with practically no binaural unmasking, they rely heavily on better-ear listening and lip reading. Traditional measures of spatial release from masking (SRM) quantify the speech reception threshold (SRT) improvement due to the azimuthal separation of speech and interferers when directly facing the speech source. The Jelfs et al. (2011) model of SRM predicts substantial benefits of orienting the head away from the target speech. Audio-only and audio-visual (AV) SRTs in normally hearing (NH) listeners and CI users confirmed model predictions of speech-facing SRM and head-orientation benefit (HOB). The lip-reading benefit (LRB) was not disrupted by a modest 30° orientation. When attending to speech with a gradually diminishing speech-to-noise-ratio (SNR), CI users were found to make little spontaneous use of their available HOB. Following a simple instruction to explore their HOB, CI users immediately reached as much as 5 dB lower SNRs. AV speech presentation significantly inhibited head movements (it nearly eradicated CI users’ spontaneous head turns), but had a limited impact on the SNRs reached post-instruction, compared to audio-only presentation. NH listeners age-matched to our CI participants made more spontaneous head turns in the free-head experiment but were poorer than CI users at exploiting their HOB post-instruction, despite their exhibiting larger objective HOB. NH listeners’ and CI users’ LRB measured 3 and 5 dB, respectively. Our findings both dispel the erroneous beliefs held by CI professionals that facing the speech constitutes an optimal listening strategy (whether for lip-reading or to optimise the use of microphone directionality) and pave the way to obvious translational applications

    The Human Auditory System

    Get PDF
    This book presents the latest findings in clinical audiology with a strong emphasis on new emerging technologies that facilitate and optimize a better assessment of the patient. The book has been edited with a strong educational perspective (all chapters include an introduction to their corresponding topic and a glossary of terms). The book contains material suitable for graduate students in audiology, ENT, hearing science and neuroscience

    Investigating the build-up of precedence effect using reflection masking

    Get PDF
    The auditory processing level involved in the build‐up of precedence [Freyman et al., J. Acoust. Soc. Am. 90, 874–884 (1991)] has been investigated here by employing reflection masked threshold (RMT) techniques. Given that RMT techniques are generally assumed to address lower levels of the auditory signal processing, such an approach represents a bottom‐up approach to the buildup of precedence. Three conditioner configurations measuring a possible buildup of reflection suppression were compared to the baseline RMT for four reflection delays ranging from 2.5–15 ms. No buildup of reflection suppression was observed for any of the conditioner configurations. Buildup of template (decrease in RMT for two of the conditioners), on the other hand, was found to be delay dependent. For five of six listeners, with reflection delay=2.5 and 15 ms, RMT decreased relative to the baseline. For 5‐ and 10‐ms delay, no change in threshold was observed. It is concluded that the low‐level auditory processing involved in RMT is not sufficient to realize a buildup of reflection suppression. This confirms suggestions that higher level processing is involved in PE buildup. The observed enhancement of reflection detection (RMT) may contribute to active suppression at higher processing levels

    Biophysical modeling of a cochlear implant system: progress on closed-loop design using a novel patient-specific evaluation platform

    Get PDF
    The modern cochlear implant is one of the most successful neural stimulation devices, which partially mimics the workings of the auditory periphery. In the last few decades it has created a paradigm shift in hearing restoration of the deaf population, which has led to more than 324,000 cochlear implant users today. Despite its great success there is great disparity in patient outcomes without clear understanding of the aetiology of this variance in implant performance. Furthermore speech recognition in adverse conditions or music appreciation is still not attainable with today's commercial technology. This motivates the research for the next generation of cochlear implants that takes advantage of recent developments in electronics, neuroscience, nanotechnology, micro-mechanics, polymer chemistry and molecular biology to deliver high fidelity sound. The main difficulties in determining the root of the problem in the cases where the cochlear implant does not perform well are two fold: first there is not a clear paradigm on how the electrical stimulation is perceived as sound by the brain, and second there is limited understanding on the plasticity effects, or learning, of the brain in response to electrical stimulation. These significant knowledge limitations impede the design of novel cochlear implant technologies, as the technical specifications that can lead to better performing implants remain undefined. The motivation of the work presented in this thesis is to compare and contrast the cochlear implant neural stimulation with the operation of the physiological healthy auditory periphery up to the level of the auditory nerve. As such design of novel cochlear implant systems can become feasible by gaining insight on the question `how well does a specific cochlear implant system approximate the healthy auditory periphery?' circumventing the necessity of complete understanding of the brain's comprehension of patterned electrical stimulation delivered from a generic cochlear implant device. A computational model, termed Digital Cochlea Stimulation and Evaluation Tool (‘DiCoStET’) has been developed to provide an objective estimate of cochlear implant performance based on neuronal activation measures, such as vector strength and average activation. A patient-specific cochlea 3D geometry is generated using a model derived by a single anatomical measurement from a patient, using non-invasive high resolution computed tomography (HRCT), and anatomically invariant human metrics and relations. Human measurements of the neuron route within the inner ear enable an innervation pattern to be modelled which joins the space from the organ of Corti to the spiral ganglion subsequently descending into the auditory nerve bundle. An electrode is inserted in the cochlea at a depth that is determined by the user of the tool. The geometric relation between the stimulation sites on the electrode and the spiral ganglion are used to estimate an activating function that will be unique for the specific patient's cochlear shape and electrode placement. This `transfer function', so to speak, between electrode and spiral ganglion serves as a `digital patient' for validating novel cochlear implant systems. The novel computational tool is intended for use by bioengineers, surgeons, audiologists and neuroscientists alike. In addition to ‘DiCoStET’ a second computational model is presented in this thesis aiming at enhancing the understanding of the physiological mechanisms of hearing, specifically the workings of the auditory synapse. The purpose of this model is to provide insight on the sound encoding mechanisms of the synapse. A hypothetical mechanism is suggested in the release of neurotransmitter vesicles that permits the auditory synapse to encode temporal patterns of sound separately from sound intensity. DiCoStET was used to examine the performance of two different types of filters used for spectral analysis in the cochlear implant system, the Gammatone type filter and the Butterworth type filter. The model outputs suggest that the Gammatone type filter performs better than the Butterworth type filter. Furthermore two stimulation strategies, the Continuous Interleaved Stimulation (CIS) and Asynchronous Interleaved Stimulation (AIS) have been compared. The estimated neuronal stimulation spatiotemporal patterns for each strategy suggest that the overall stimulation pattern is not greatly affected by the temporal sequence change. However the finer detail of neuronal activation is different between the two strategies, and when compared to healthy neuronal activation patterns the conjecture is made that the sequential stimulation of CIS hinders the transmission of sound fine structure information to the brain. The effect of the two models developed is the feasibility of collaborative work emanating from various disciplines; especially electrical engineering, auditory physiology and neuroscience for the development of novel cochlear implant systems. This is achieved by using the concept of a `digital patient' whose artificial neuronal activation is compared to a healthy scenario in a computationally efficient manner to allow practical simulation times.Open Acces

    Learning-Based Reference-Free Speech Quality Assessment for Normal Hearing and Hearing Impaired Applications

    Get PDF
    Accurate speech quality measures are highly attractive and beneficial in the design, fine-tuning, and benchmarking of speech processing algorithms, devices, and communication systems. Switching from narrowband telecommunication to wideband telephony is a change within the telecommunication industry which provides users with better speech quality experience but introduces a number of challenges in speech processing. Noise is the most common distortion on audio signals and as a result there have been a lot of studies on developing high performance noise reduction algorithms. Assistive hearing devices are designed to decrease communication difficulties for people with loss of hearing. As the algorithms within these devices become more advanced, it becomes increasingly crucial to develop accurate and robust quality metrics to assess their performance. Objective speech quality measurements are more attractive compared to subjective assessments as they are cost-effective and subjective variability is eliminated. Although there has been extensive research on objective speech quality evaluation for narrowband speech, those methods are unsuitable for wideband telephony. In the case of hearing-impaired applications, objective quality assessment is challenging as it has to be capable of distinguishing between desired modifications which make signals audible and undesired artifacts. In this thesis a model is proposed that allows extracting two sets of features from the distorted signal only. This approach which is called reference-free (nonintrusive) assessment is attractive as it does not need access to the reference signal. Although this benefit makes nonintrusive assessments suitable for real-time applications, more features need to be extracted and smartly combined to provide comparable accuracy as intrusive metrics. Two feature vectors are proposed to extract information from distorted signals and their performance is examined in three studies. In the first study, both feature vectors are trained on various portions of a noise reduction database for normal hearing applications. In the second study, the same investigation is performed on two sets of databases acquired through several hearing aids. Third study examined the generalizability of the proposed metrics on benchmarking four wireless remote microphones in a variety of environmental conditions. Machine learning techniques are deployed for training the models in the three studies. The studies show that one of the feature sets is robust when trained on different portions of the data from different databases and it also provides good quality prediction accuracy for both normal hearing and hearing-impaired applications
    • …
    corecore