45,034 research outputs found
The Band Excitation Method in Scanning Probe Microscopy for Rapid Mapping of Energy Dissipation on the Nanoscale
Mapping energy transformation pathways and dissipation on the nanoscale and
understanding the role of local structure on dissipative behavior is a
challenge for imaging in areas ranging from electronics and information
technologies to efficient energy production. Here we develop a novel Scanning
Probe Microscopy (SPM) technique in which the cantilever is excited and the
response is recorded over a band of frequencies simultaneously rather than at a
single frequency as in conventional SPMs. This band excitation (BE) SPM allows
very rapid acquisition of the full frequency response at each point (i.e.
transfer function) in an image and in particular enables the direct measurement
of energy dissipation through the determination of the Q-factor of the
cantilever-sample system. The BE method is demonstrated for force-distance and
voltage spectroscopies and for magnetic dissipation imaging with sensitivity
close to the thermomechanical limit. The applicability of BE for various SPMs
is analyzed, and the method is expected to be universally applicable to all
ambient and liquid SPMs.Comment: 32 pages, 9 figures, accepted for publication in Nanotechnolog
Simultaneous use of Individual and Joint Regularization Terms in Compressive Sensing: Joint Reconstruction of Multi-Channel Multi-Contrast MRI Acquisitions
Purpose: A time-efficient strategy to acquire high-quality multi-contrast
images is to reconstruct undersampled data with joint regularization terms that
leverage common information across contrasts. However, these terms can cause
leakage of uncommon features among contrasts, compromising diagnostic utility.
The goal of this study is to develop a compressive sensing method for
multi-channel multi-contrast magnetic resonance imaging (MRI) that optimally
utilizes shared information while preventing feature leakage.
Theory: Joint regularization terms group sparsity and colour total variation
are used to exploit common features across images while individual sparsity and
total variation are also used to prevent leakage of distinct features across
contrasts. The multi-channel multi-contrast reconstruction problem is solved
via a fast algorithm based on Alternating Direction Method of Multipliers.
Methods: The proposed method is compared against using only individual and
only joint regularization terms in reconstruction. Comparisons were performed
on single-channel simulated and multi-channel in-vivo datasets in terms of
reconstruction quality and neuroradiologist reader scores.
Results: The proposed method demonstrates rapid convergence and improved
image quality for both simulated and in-vivo datasets. Furthermore, while
reconstructions that solely use joint regularization terms are prone to
leakage-of-features, the proposed method reliably avoids leakage via
simultaneous use of joint and individual terms.
Conclusion: The proposed compressive sensing method performs fast
reconstruction of multi-channel multi-contrast MRI data with improved image
quality. It offers reliability against feature leakage in joint
reconstructions, thereby holding great promise for clinical use.Comment: 13 pages, 13 figures. Submitted for possible publicatio
Cortical depth dependent functional responses in humans at 7T: improved specificity with 3D GRASE
Ultra high fields (7T and above) allow functional imaging with high contrast-to-noise ratios and improved spatial resolution. This, along with improved hardware and imaging techniques, allow investigating columnar and laminar functional responses. Using gradient-echo (GE) (T2* weighted) based sequences, layer specific responses have been recorded from human (and animal) primary visual areas. However, their increased sensitivity to large surface veins potentially clouds detecting and interpreting layer specific responses. Conversely, spin-echo (SE) (T2 weighted) sequences are less sensitive to large veins and have been used to map cortical columns in humans. T2 weighted 3D GRASE with inner volume selection provides high isotropic resolution over extended volumes, overcoming some of the many technical limitations of conventional 2D SE-EPI, whereby making layer specific investigations feasible. Further, the demonstration of columnar level specificity with 3D GRASE, despite contributions from both stimulated echoes and conventional T2 contrast, has made it an attractive alternative over 2D SE-EPI. Here, we assess the spatial specificity of cortical depth dependent 3D GRASE functional responses in human V1 and hMT by comparing it to GE responses. In doing so we demonstrate that 3D GRASE is less sensitive to contributions from large veins in superficial layers, while showing increased specificity (functional tuning) throughout the cortex compared to GE
Respiratory organ motion in interventional MRI : tracking, guiding and modeling
Respiratory organ motion is one of the major challenges in interventional MRI, particularly in interventions with therapeutic ultrasound in the abdominal region. High-intensity focused ultrasound found an application in interventional MRI for noninvasive treatments of different abnormalities. In order to guide surgical and treatment interventions, organ motion imaging and modeling is commonly required before a treatment start. Accurate tracking of organ motion during various interventional MRI procedures is prerequisite for a successful outcome and safe therapy.
In this thesis, an attempt has been made to develop approaches using focused ultrasound which could be used in future clinically for the treatment of abdominal organs, such as the liver and the kidney. Two distinct methods have been presented with its ex vivo and in vivo treatment results. In the first method, an MR-based pencil-beam navigator has been used to track organ motion and provide the motion information for acoustic focal point steering, while in the second approach a hybrid imaging using both ultrasound and magnetic resonance imaging was combined for advanced guiding capabilities.
Organ motion modeling and four-dimensional imaging of organ motion is increasingly required before the surgical interventions. However, due to the current safety limitations and hardware restrictions, the MR acquisition of a time-resolved sequence of volumetric images is not possible with high temporal and spatial resolution. A novel multislice acquisition scheme that is based on a two-dimensional navigator, instead of a commonly used pencil-beam navigator, was devised to acquire the data slices and the corresponding navigator simultaneously using a CAIPIRINHA parallel imaging method. The acquisition duration for four-dimensional dataset sampling is reduced compared to the existing approaches, while the image contrast and quality are improved as well.
Tracking respiratory organ motion is required in interventional procedures and during MR imaging of moving organs. An MR-based navigator is commonly used, however, it is usually associated with image artifacts, such as signal voids. Spectrally selective navigators can come in handy in cases where the imaging organ is surrounding with an adipose tissue, because it can provide an indirect measure of organ motion. A novel spectrally selective navigator based on a crossed-pair navigator has been developed. Experiments show the advantages of the application of this novel navigator for the volumetric imaging of the liver in vivo, where this navigator was used to gate the gradient-recalled echo sequence
Feasibility of automated 3-dimensional magnetic resonance imaging pancreas segmentation.
PurposeWith the advent of MR guided radiotherapy, internal organ motion can be imaged simultaneously during treatment. In this study, we evaluate the feasibility of pancreas MRI segmentation using state-of-the-art segmentation methods.Methods and materialT2 weighted HASTE and T1 weighted VIBE images were acquired on 3 patients and 2 healthy volunteers for a total of 12 imaging volumes. A novel dictionary learning (DL) method was used to segment the pancreas and compared to t mean-shift merging (MSM), distance regularized level set (DRLS), graph cuts (GC) and the segmentation results were compared to manual contours using Dice's index (DI), Hausdorff distance and shift of the-center-of-the-organ (SHIFT).ResultsAll VIBE images were successfully segmented by at least one of the auto-segmentation method with DI >0.83 and SHIFT ≤2 mm using the best automated segmentation method. The automated segmentation error of HASTE images was significantly greater. DL is statistically superior to the other methods in Dice's overlapping index. For the Hausdorff distance and SHIFT measurement, DRLS and DL performed slightly superior to the GC method, and substantially superior to MSM. DL required least human supervision and was faster to compute.ConclusionOur study demonstrated potential feasibility of automated segmentation of the pancreas on MRI images with minimal human supervision at the beginning of imaging acquisition. The achieved accuracy is promising for organ localization
- …